Optimization and validation of a bioanalytical HPLC-UV technique for simultaneous determination of underivatized phenylalanine and tyrosine in the blood for phenylketonuria diagnosis and monitoring

被引:2
作者
Rabti, Hadjira [1 ,2 ,6 ]
Amrane, Mounira [1 ,3 ]
Lalaouna, Abdeldjalil [4 ]
Flilissa, Abdenacer [1 ]
Benguerba, Yacine [5 ]
机构
[1] Ferhat Abbas Set 1 Univ, Lab Cardiovasc Dis Genet & Nutr Origin LMCGN, Setif, Algeria
[2] Salah Boubnider Constantine 3 Univ, Fac Proc Engn, Dept Pharmaceut Engn, Constantine, Algeria
[3] Mokhtari Abdelghani Canc Ctr, Elbez, Setif, Algeria
[4] Salah Boubnider Constantine 3 Univ, Fac Med, Pharm Dept, Analyt Chem Lab, Constantine, Algeria
[5] Ferhat ABBAS Univ Setif 1, Biopharm & Pharmatechnie Lab LBPT, Setif, Algeria
[6] Ferhat Abbas Setif 1 Univ, Lab Cardiovasc Dis Genet & Nutr Origin LMCGN, Setif 19000, Algeria
关键词
biological samples; central composite experimental design; HPLC-UV; phenylalanine/tyrosine ratio; phenylketonuria; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; AMINO-ACIDS; PLASMA PHENYLALANINE; SAMPLES; DESIGN; SERUM; ASSAY;
D O I
10.1002/bmc.5758
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to develop a fast, accurate, and precise high-performance liquid chromatography with UV detection method for simultaneous analysis of underivatized phenylalanine (Phe) and tyrosine (Tyr) in biological samples. Separation of the analytes was accomplished using a Discovery HS F5-3 column, which offered better retention and peak symmetry for the tested analytes. Chromatographic conditions were optimized using central composite experimental design, and three factors were investigated: the concentration of ammonium acetate (A), the acetonitrile proportion in the mobile phase (B) and the column oven temperature (C). The approach was verified using beta-expectation tolerance intervals for total error measurement that did not exceed 15%. Optimal settings were A = 50 mm, B = 24% and C = 28degree celsius. The method applicability was determined using human plasma from 75 volunteers. The limits of detection and quantification of the technique were satisfactory at 9 and 29 mu m for Phe and 4 and 13 mu m for Tyr. The mean analytical bias in spiking levels was acceptable, ranging from -1.649 to +1.659% for both substances, with RSD <5% in all instances. The suggested approach was successfully used to analyze Phe and Tyr in human blood samples and calculate the Phe/Tyr ratio.
引用
收藏
页数:13
相关论文
共 45 条
[1]  
[Anonymous], 2011, GUIDELINE BIOANALYTI
[2]  
ATHERTON ND, 1989, CLIN CHEM, V35, P975
[3]   Response surface methodology: A review on its applications and challenges in microbial cultures [J].
Breig, Sura Jasem Mohammed ;
Luti, Khalid Jaber Kadhum .
MATERIALS TODAY-PROCEEDINGS, 2021, 42 :2277-2284
[4]   Validation of the phenylalanine/tyrosine ratio determined by tandem mass spectrometry:: Sensitive newborn screening for phenylketonuria [J].
Ceglarek, U ;
Müller, P ;
Stach, B ;
Bührdel, P ;
Thiery, J ;
Kiess, W .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (07) :693-697
[5]  
Contreras J, 2015, MEDICC REV, V17, P23, DOI [10.37757/mr2015.v17.n1.6, 10.37757/MR2015.V17.N1.6]
[6]  
Danafar H, 2015, PHARMACEUT BIOMED RE, V1, P11, DOI [10.18869/acadpub.pbr.1.3.11, 10.18869/acadpub.pbr.1.3.11, DOI 10.3109/10837450.2015.1125920]
[7]   L-Phenylalanine concentration in blood of phenylketonuria patients: a modified enzyme colorimetric assay compared with amino acid analysis, tandem mass spectrometry, and HPLC methods [J].
De Silva, Veronica ;
Oldham, Charlie D. ;
May, Sheldon W. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (09) :1271-1279
[8]   Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots [J].
Deng, CH ;
Deng, YH ;
Wang, B ;
Yang, XH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :407-413
[9]   Improved tandem mass spectrometry (MS/MS) derivatized method for the detection of tyrosinemia type I, amino acids and acylcarnitine disorders using a single extraction process [J].
Dhillon, Kuldeep S. ;
Bhandal, Ajit S. ;
Aznar, Constantino P. ;
Lorey, Fred W. ;
Neogi, Partha .
CLINICA CHIMICA ACTA, 2011, 412 (11-12) :873-879
[10]   Selective Screening for Inborn Errors of Metabolism: A Report of Six Years Experience [J].
Dogan, Esra ;
Uysal, Sezer ;
Ozturk, Yesim ;
Arslan, Nur ;
Coker, Canan .
IRANIAN JOURNAL OF PEDIATRICS, 2017, 27 (05)