Hemodynamic performance evaluation of neonatal ECMO double lumen cannula using fluid-structure interaction

被引:2
|
作者
Ahmad, Faiq [1 ]
Cheema, Taqi Ahmad [1 ]
Rehman, Khawar [2 ,3 ]
Ullah, Minhaj [1 ]
Jamil, Muhammad [4 ,5 ]
Park, Cheol Woo [6 ,7 ]
机构
[1] GIK Inst Engn Sci & Technol, Fac Mech Engn, Topi 23460, Pakistan
[2] Hanyang Univ, Dept Civil & Environm Engn, Seoul 04763, South Korea
[3] GIK Inst Engn Sci & Technol, Dept Civil Engn, Topi 23460, Pakistan
[4] Anal Grp, Starfish Med, 455 Boleskine Rd, Victoria, BC, Canada
[5] KoC Univ, Dept Mech Engn, Sariyar, TR-34450 Istanbul, Turkiye
[6] Kyungpook Natl Univ, Sch Mech Engn, 80 Daehak Ro, Daegu 41566, South Korea
[7] Kyungpook Natl Univ, Sch Mech Engn, 80 Daehak Ro, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
blood damage; double lumen cannula (DLC); extra corporeal membrane oxygenation (ECMO); fluid-structure interaction (FSI); hemodynamic performance; BLOOD DAMAGE; FLOW; OXYGENATION; DESIGN; IMPACT;
D O I
10.1002/cnm.3706
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Extra corporeal membrane oxygenation (ECMO) is an artificial oxygenation facility, employed in situations of cardio-pulmonary failure. Some diseases i.e., acute respiratory distress syndrome, pulmonary hypertension, corona virus disease (COVID-19) etc. affect oxygenation performance of the lungs thus requiring the need of artificial oxygenation. Critical care teams used ECMO technique during the COVID-19 pandemic to support the heart and lungs of COVID-19 patients who had an acute respiratory or cardiac failure. Double Lumen Cannula (DLC) is one of the most critical components of ECMO as it resides inside the patient and, connects patient with external oxygenation circuit. DLC facilitates delivery and drainage of blood from the patient's body. DLC is characterized by delicate balance of internal and external flows inside a limited space of the right atrium (RA). An optimal performance of the DLC necessitates structural stability under biological and hemodynamic loads, a fact that has been overlooked by previously published studies. In the past, many researchers experimentally and computationally investigated the hemodynamic performance of DLC by employing Eulerian approach, which evaluate instantaneous blood damage without considering blood shear exposure history (qualitative assessment only). The present study is an attempt to address the aforementioned limitations of the previous studies by employing Lagrangian (quantitative assessment) and incorporating the effect of fluid-structure interaction (FSI) to study the hemodynamic performance of neonatal DLC. The study was performed by solving three-dimensional continuity, momentum, and structural mechanics equation(s) by numerical methods for the blood flow through neonatal DLC. A two-way coupled FSI analysis was performed to analyze the effect of DLC structural deformation on its hemodynamic performance. Results show that the return lumen was the most critical section with maximum pressure drop, velocity, shear stresses, and blood damage. Recirculation and residence time of blood in the right atrium (RA) increases with increasing blood flow rates. Considering the structural deformation has led to higher blood damage inside the DLC-atrium system. Maximum Von-Mises stress was present on the side edges of the return lumen that showed direct proportionality with the blood flow rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Modeling and evaluation of biomechanics and hemodynamic based on patient-specific small intracranial aneurysm using fluid-structure interaction
    Ma, Zijian
    Zhuang, Yijie
    Long, Xiaoao
    Yu, Bo
    Li, Jiawang
    Yang, Yan
    Yu, Yingxin
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 244
  • [2] Fluid-structure interaction for aerodynamic performance evaluation of flapping wing with passive pitching motion
    Hussain, Syed Baleegh
    Shahzad, Aamer
    Qadri, Muhammad Nafees Mumtaz
    Shams, Taimur Ali
    Shah, Imran
    Salamat, Shuaib
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (14) : 6923 - 6939
  • [3] Stability Evaluation of a Simplified Reclaimer Using Fluid-Structure Interaction
    Januario, Joao Rodolfo
    Landre Junior, Janes
    Maia, Cristiana Brasil
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [4] Hemodynamic and thrombogenic analysis of a trileaflet polymeric valve using a fluid-structure interaction approach
    Piatti, Filippo
    Sturla, Francesco
    Marom, Gil
    Sheriff, Jawaad
    Claiborne, Thomas E.
    Slepian, Marvin J.
    Redaelli, Alberto
    Bluestein, Danny
    JOURNAL OF BIOMECHANICS, 2015, 48 (13) : 3641 - 3649
  • [5] Fluid-structure interaction analysis for double cable structures
    Wang, Chunjiang, 1600, Tianjin University (47): : 57 - 63
  • [6] Hemodynamic study of blood flow in the aorta during the interventional robot treatment using fluid-structure interaction
    Zhu, Zongming
    Ji, Suqiang
    Liang, Liang
    Wang, Hao
    Xia, Haoyu
    Tang, Puhua
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2023, 22 (06) : 1857 - 1872
  • [7] Investigation of Different Activities on the Hemodynamic Parameters of Left External Carotid Artery Using Fluid-Structure Interaction
    Kamali, Reza
    Kheirandish, Sasan
    Paktinat, Khalil
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2019, 43 (Suppl 1) : 91 - 106
  • [8] Evaluation of a coupling interface for solving fluid-structure interaction problems
    Garelli, Luciano
    Schauer, Marco
    Rios Rodriguez, Gustavo
    Langer, Sabine C.
    Storti, Mario A.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2016, 58 : 117 - 126
  • [9] Systematic evaluation of the interface description for fluid-structure interaction simulations using the isogeometric mortar-based mapping
    Apostolatos, Andreas
    De Nayer, Guillaume
    Bletzinger, Kai-Uwe
    Breuer, Michael
    Wuechner, Roland
    JOURNAL OF FLUIDS AND STRUCTURES, 2019, 86 : 368 - 399
  • [10] Hemodynamic analysis of unilateral and bilateral renal artery stenosis based on fluid-structure interaction
    Liu, Bingxin
    Zhao, Jiawei
    Chen, Xuehui
    Fang, Kun
    Yang, Weidong
    Zhang, Xuelan
    Shu, Chang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (01) : 25 - 36