A PROSPECTIVE COMPARISON OF ULTRASOUND GUIDED VERSUS PALPATION METHOD FOR RADIAL ARTERY CATHETER PLACEMENT

被引:0
作者
Kumar, Kamal [1 ,2 ,3 ]
Khuwaja, Amin Muhammad [1 ]
Mangi, Ali Raza [1 ]
Khan, Sajjad Ahmed [1 ]
Tariq, Hamna [1 ]
Zaheeruddin, Sayed [1 ]
Akhtar, Saleha [1 ]
机构
[1] Natl Inst Cardiovasc Dis, Karachi, Pakistan
[2] Natl Inst Cardiovasc Dis NICVD, Dept Anaesthesia, Karachi, Pakistan
[3] Natl Inst Cardiovasc Dis NICVD, SICU, Karachi, Pakistan
来源
PAKISTAN HEART JOURNAL | 2023年 / 56卷 / 01期
关键词
radial artery cannulation; ultrasound; palpation; vygon catheter; CANNULATION; METAANALYSIS; GUIDANCE; TRIAL; ADULT;
D O I
10.47144/phj.v56i1.2414
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The objective of this study was to assess the effectiveness of ultrasound guided vs. conventional palpation method for radial artery cannulation in the operating room for patients undergoing elective open-heart operations.Methodology: This prospective observational study was carried at the National Institute of Cardiovascular Disease (NICVD) in Karachi and Sukkur. All cannulation procedures were performed by anesthesia residents (R-1). Two equal sized independent groups of patients based on radial artery cannulation technique, either ultrasound guided (USG) or conventional palpation method (CPM) were recruited. Artery cannulation success along with number of attempts, total duration, number of additional operators, need for change of site, and complications were recorded.Results: A total of 70 patients were recruited in each of the group, mean patient age was 52.43 +/- 13.53 years vs. 50.71 +/- 14.1 years; p=0.605 with proportion of male patients as 65.7% (46) vs. 77.1% (54); p=0.290, for USG and CPM, respectively. Artery cannulation success rate was 74.3% (52) vs. 80% (56); p=0.569, mean number of attempts was 1.71 +/- 1.05 vs. 1.51 +/- 0.89; p=0.391, mean total duration was 7.76 +/- 3.78 minutes vs. 5.42 +/- 8.2 minutes; p=0.131, mean number of additional operators was 0.74 +/- 0.44 vs. 0.89 +/- 0.32; p=0.128, need for change of site was 11.4% (8) vs. 2.9% (2); p=0.356, and complications were observed in 8.6% (6) vs. 2.9% (2); p=0.614 for USG and CPM, respectively.Conclusion: In this observational study, no significant differences were observed in the effectiveness of USG and CPM for radial artery cannulation when performed by newly inducted anesthesia residents.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 16 条
[1]  
Ammar A, 2017, J Postgrad Med Inst., V31, P8
[2]   Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials [J].
Bhattacharjee, Sulagna ;
Maitra, Souvik ;
Baidya, Dalim K. .
JOURNAL OF CLINICAL ANESTHESIA, 2018, 47 :54-59
[3]   Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations [J].
Brzezinski, Marek ;
Luisetti, Thomas ;
London, Martin J. .
ANESTHESIA AND ANALGESIA, 2009, 109 (06) :1763-1781
[4]   Central venous cannulation in patients with liver disease and coagulopathy - a prospective audit [J].
Fisher, NC ;
Mutimer, DJ .
INTENSIVE CARE MEDICINE, 1999, 25 (05) :481-485
[5]   Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit [J].
Froehlich, Curt D. ;
Rigby, Mark R. ;
Rosenberg, Eli S. ;
Li, Ruosha ;
Roerig, Pei-Ling J. ;
Easley, Kirk A. ;
Stockwell, Jana A. .
CRITICAL CARE MEDICINE, 2009, 37 (03) :1090-1096
[6]   Effects of ultrasound-guided radial artery catheterization: an updated meta-analysis [J].
Gao, Yan-Bing ;
Yan, Jun-Hong ;
Gao, Fu-Quan ;
Pan, Lei ;
Wang, Xiao-Zhi ;
Lv, Chang-Jun .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (01) :50-55
[7]   Ultrasound Guidance Facilitates Radial Artery Catheterization A Meta-analysis With Trial Sequential Analysis of Randomized Controlled Trials [J].
Gu, Wan-Jie ;
Wu, Xiang-Dong ;
Wang, Fei ;
Ma, Zheng-Liang ;
Gu, Xiao-Ping .
CHEST, 2016, 149 (01) :166-179
[8]  
Gu WJ, 2014, CRIT CARE, V18
[9]   Ultrasonic locating devices for central venous cannulation: meta-analysis [J].
Hind, D ;
Calvert, N ;
McWilliams, R ;
Davidson, A ;
Paisley, S ;
Beverley, C ;
Thomas, S .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7411) :361-364
[10]  
Peters C, 2015, CAN J ANESTH, V62, P1161, DOI 10.1007/s12630-015-0426-8