BackgroundAmplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial appendage (LAA) landing zone. However, mean, perimeter-, or area-derived diameter might be more accurate measures for device sizing.MethodsRetrospective analysis of 150 consecutive patients undergoing LAAO is guided by pre-procedural cardiac CT. A total of 117 patients were included; 7 were excluded due to renal failure and 26 due to closure with the sandwich technique. The maximum, mean, area-, and perimeter-derived diameters of the landing zone were derived from pre-procedural cardiac CT scans, and their accuracy to predict the implanted device size was investigated. The predicted device size was determined based on the currently recommended sizing algorithm. Peri-device leak (PDL) was assessed (grade 1-3) along with the underlying mechanism.ResultsDevice-sizing accuracy was superior for mean, area-, and perimeter derived diameters compared with the maximal diameter, especially for eccentric landing zones. Mean difference between predicted and actually implanted device size was 0.08 mm (+/- 2.77), 0.30 mm (+/- 2.40), - 0.39 mm (+/- 2.43), and - 2.55 mm (+/- 2.57) across mean, area-derived, perimeter-derived, and maximal diameter, respectively. Grade 3 peri-device leak was seen in 8.5% of implants without a significant association to the eccentricity of the landing zone. The leading mechanism for PDL was device malalignment.ConclusionOur results indicate mean, area-, and perimeter-derived diameters of the device landing zone to perform similar and superior in device-sizing accuracy compared with the maximum diameter.
引用
收藏
页码:785 / 795
页数:11
相关论文
共 23 条
[1]   Peridevice Leak After Left Atrial Appendage Occlusion [J].
Alkhouli, Mohamad ;
De Backer, Ole ;
Ellis, Christopher R. ;
Nielsen-Kudsk, Jens Erik ;
Sievert, Horst ;
Natale, Andrea ;
Lakkireddy, Dhanunjaya ;
Holmes, David R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) :627-642
[2]   Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion Insights From the NCDR LAAO Registry [J].
Alkhouli, Mohamad ;
Du, Chengan ;
Killu, Ammar ;
Simard, Trevor ;
Noseworthy, Peter A. ;
Friedman, Paul A. ;
Curtis, Jeptha P. ;
V. Freeman, James ;
Holmes, David R. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (06) :766-778
[3]   Interobserver agreement issues in radiology [J].
Benchoufi, M. ;
Matzner-Lober, E. ;
Molinari, N. ;
Jannot, A-S ;
Soyer, P. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (10) :639-641
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Pre-procedural determination of device size in left atrial appendage occlusion using three-dimensional cardiac computed tomography [J].
Cho, Iksung ;
Kim, William D. ;
Lee, Oh Hyun ;
Cha, Min Jae ;
Seo, Jiwon ;
Shim, Chi Young ;
Pak, Hui-Nam ;
Joung, Boyoung ;
Hong, Geu-Ru ;
Gransar, Heidi ;
Shin, Seung Yong ;
Kim, Jung-Sun .
SCIENTIFIC REPORTS, 2021, 11 (01)
[6]   Impact of Computational Modeling on Transcatheter Left Atrial Appendage Closure Efficiency and Outcomes [J].
De Backer, Ole ;
Iriart, Xavier ;
Kefer, Joelle ;
Nielsen-Kudsk, Jens Erik ;
Aminian, Adel ;
Rosseel, Liesbeth ;
Kofoed, Klaus Fuglsang ;
Odenstedt, Jacob ;
Berti, Sergio ;
Saw, Jacqueline ;
Sondergaard, Lars ;
Garot, Philippe .
JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) :655-666
[7]   Prospective, randomized comparison of 3-dimensional computed tomography guidance versus TEE data for left atrial appendage occlusion (PRO3DLAAO) [J].
Eng, Marvin H. ;
Wang, Dee Dee ;
Greenbaum, Adam B. ;
Gheewala, Neil ;
Kupsky, Daniel ;
Aka, Tongwa ;
Song, Thomas ;
Kendall, Bradley James ;
Wyman, Janet ;
Myers, Eric ;
Forbes, Michael ;
O'Neill, William W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (02) :401-407
[8]   Usefulness of a novel sizing chart for left atrial appendage occlusion with the Amplatzer Amulet [J].
Freixa, Xavier ;
Cepas-Guillen, Pedro ;
Korsholm, Kasper ;
Kramer, Anders ;
Regueiro, Ander ;
Flores-Umanzor, Eduardo ;
Sanchis, Laura ;
Arenas-Loriente, Andrea ;
Jensen, Jesper Moller ;
Nielsen-Kudsk, Jens Erik .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (05) :801-809
[9]   Left atrial appendage occlusion in chicken-wing anatomies: Imaging assessment, procedural, and clinical outcomes of the "sandwich technique" [J].
Freixa, Xavier ;
Tzikas, Apostolos ;
Aminian, Adel ;
Flores-Umanzor, Eduardo ;
De Backer, Ole ;
Korsholm, Kasper ;
Ben Yedder, Mohamed ;
Gonzalez-Ferreiro, Rocio ;
Agudelo-Montanez, Victor ;
Gilhofer, Thomas ;
Simon, Francois ;
Samaras, Athanasios ;
Regueiro, Ander ;
Sondergaard, Lars ;
Cruz-Gonzalez, Ignacio ;
Arzamendi, Dabit ;
Saw, Jacqueline ;
Ibrahim, Reda ;
Nielsen-Kudsk, Jens Erik .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (07) :E1025-E1032
[10]   Left atrial appendage occlusion with the Amplatzer Amulet: update on device sizing [J].
Freixa, Xavier ;
Aminian, Adel ;
Tzikas, Apostolos ;
Saw, Jacqueline ;
Nielsen-Kudsk, Jens-Erick ;
Ghanem, Alexander ;
Schmidt, Boris ;
Hildick-Smith, David .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (01) :71-78