Performance assessment and optimization of three-dimensional hybrid slot-effusion jet cooling configuration of an annular combustor liner

被引:7
作者
Revulagadda, Ananda Prasanna [1 ]
Adapa, Buchi Raju [1 ]
Balaji, C. [1 ]
Pattamatta, Arvind [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Chennai 600036, India
关键词
Combustor liner cooling; Genetic algorithm; Optimization; Hybrid cooling; Kriging model; Infrared Thermography; COMPOUND ANGLE HOLES; HEAT-TRANSFER; FILM EFFECTIVENESS; FLAT-PLATE; SIMULATION; INJECTION; TURBULENCE; DESIGN; ROWS;
D O I
10.1016/j.applthermaleng.2023.122198
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the film cooling performance of a three-dimensional (3D) hybrid slot-effusion configuration and its advantages over a baseline pure 3D slot cooling are investigated in detail using both experimental and numerical investigations. The numerical model is validated by in-house experiments conducted on a hybrid cooling configuration with a 3D slot and staggered effusion array. Infrared thermography and hot wire anemometry are used in this study to analyze the thermal and flow fields. The cooling performance of pure 3D slot and hybrid configurations is compared under identical coolant consumption. The coolant mass flow ratio (MFR) determines the cooling behavior in hybrid cooling. At low MFRs, hybrid cooling is less effective than pure 3D slot cooling. In addition, it is observed that there exists an optimal MFR where hybrid cooling outperforms 3D slot cooling. Subsequently, the effect of key design variables on the cooling performance of the hybrid configuration is studied, and they are optimized at typical combustor operating conditions using a genetic algorithm coupled to a Kriging surrogate model. The optimal configuration is experimentally tested at laboratory conditions and compared with the baseline 3D slot configuration, and it is noted that there is a significant improvement in the cooling effectiveness. Additionally, the film cooling performance of the optimized configuration at combustor representative operating conditions of maximum BR of 2 shows an enhancement of 16% in area-averaged adiabatic effectiveness and a 60% reduction in the standard deviation of local adiabatic effectiveness as compared to the baseline 3D slot cooling.
引用
收藏
页数:19
相关论文
共 46 条
[1]   FILM COOLING STUDIES ON COMBINED THREE-DIMENSIONAL SLOT AND EFFUSION JET CONFIGURATION OF AN ANNULAR COMBUSTOR LINER [J].
Adapa, Buchi Raju ;
Revulagadda, Ananda Prasanna ;
Pattamatta, Arvind ;
Balaji, C. .
INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2022, 49 (03) :61-80
[2]   Turbulence intensity effects on film cooling and heat transfer from compound angle holes with particular application to gas turbine blades [J].
Al-Hamadi, AK ;
Jubran, BA ;
Theodoridis, G .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (14) :1449-1457
[3]  
Andreini A, 2010, PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 4, PTS A AND B, P763
[4]  
Andrews G., 1989, 89GT7 ASME, VVolume 79160, pV004T08A002
[5]  
Andrews G., 1995, Turbo Expo: Power for Land, Sea, and Air, V78811
[6]  
Andrews G., 1991, ASME 1991 INT GAS TU
[7]  
[Anonymous], 2013, ANSYS FLUENT THEOR G
[8]   Computational study of film cooling from single and two staggered rows of novel semi-circular cooling holes including coolant plenum [J].
Asghar, F. H. ;
Hyder, M. J. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :329-334
[9]  
Bittlinger G., 1994, ASME 1994 INT GAS TU
[10]  
Ceccherini A, 2009, PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, P1431