Analysis of Individualized Silicone Rubber Bolus Using Fan Beam Computed Tomography in Postmastectomy Radiotherapy: A Dosimetric Evaluation and Skin Acute Radiation Dermatitis Survey

被引:1
作者
Chen, Xue-mei [1 ]
Xu, Chen-di [1 ]
Zeng, Li-ping [2 ,3 ]
Huang, Xiao-tong [1 ]
Chen, Ao-qiang [1 ]
Liu, Lu [1 ]
Lin, Liu-wen [1 ]
Jia, Le-cheng [4 ]
Li, Hua [4 ]
Jiang, Xiao-bo [1 ,5 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Oncol South China, Canc Ctr, Guangzhou, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Shenzhen, Guangdong, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Shenzhen Hosp, Shenzhen, Guangdong, Peoples R China
[4] Shenzhen United Imaging Res Inst Innovat Med Equip, Shenzhen, Guangdong, Peoples R China
[5] Sun Yat Sen Univ, State Key Lab Oncol South China, Canc Ctr, Guangzhou 510060, Peoples R China
关键词
postmastectomy radiotherapy; dosimetry; bolus; fan beam computed tomography; planning target volume; organ at risk; acute radiation dermatitis; BRASS MESH BOLUS; CHEST-WALL; THERAPY; TOXICITY; ONCOLOGY;
D O I
10.1177/15330338241229367
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To investigate the dosimetric effects of using individualized silicone rubber (SR) bolus on the target area and organs at risk (OARs) during postmastectomy radiotherapy (PMRT), as well as evaluate skin acute radiation dermatitis (ARD). Methods: A retrospective study was performed on 30 patients with breast cancer. Each patient was prepared with an individualized SR bolus of 3 mm thickness. Fan-beam computed tomography (FBCT) was performed at the first and second fractions, and then once a week for a total of 5 times. Dosimetric metrics such as homogeneity index (HI), conformity index (CI), skin dose (SD), and OARs including the heart, lungs, and spinal cord were compared between the original plan and the FBCTs. The acute side effects were recorded. Results: In targets' dosimetric metrics, there were no significant differences in D-mean and V-105% between planning computed tomography (CT) and actual treatments (P > .05), while the differences in D-95%, V-95%, HI, and CI were statistically significant (P < .05). In OARs, there were no significant differences between the D-mean, V-5, and V-20 of the affected lung, V-5 of the heart and D-max of the spinal cord (P > .05) except the V-30 of affected lung, which was slightly lower than the planning CT (P < .05). In SD, both D-max and D-mean in actual treatments were increased than plan A, and the difference was statistically significant (P < .05), while the skin-V-20 and skin-V-30 has no difference. Among the 30 patients, only one patient had no skin ARD, and 5 patients developed ARD of grade 2, while the remaining 24 patients were grade 1. Conclusion: The OR bolus showed good anastomoses and high interfraction reproducibility with the chest wall, and did not cause deformation during irradiation. It ensured accurate dose delivery of the target and OARs during the treatment, which may increase SD by over 101%. In this study, no cases of grade 3 skin ARD were observed. However, the potential of using OR bolus to reduce grade 1 and 2 skin ARD warrants further investigation with a larger sample size.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Local failure and acute radiodermatological toxicity in patients undergoing radiation therapy with and without postmastectomy chest wall bolus: Is bolus ever necessary?
    Abel, Stephen
    Renz, Paul
    Trombetta, Mark
    Cowher, Michael
    Werts, E. Day
    Julian, Thomas B.
    Wegner, Rodney
    [J]. PRACTICAL RADIATION ONCOLOGY, 2017, 7 (03) : 167 - 172
  • [2] Dosimetric effects of brass mesh bolus on skin dose and dose at depth for postmastectomy chest wall irradiation
    Al-Rahbi, Zakiya S.
    Cutajar, Dean L.
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 84 - 93
  • [3] Babic Steven, 2002, J Appl Clin Med Phys, V3, P170, DOI 10.1120/1.1471552
  • [4] Development and validation of a 3D-printed bolus cap for total scalp irradiation
    Baltz, Garrett C.
    Chi, Pai-Chun Melinda
    Wong, Pei-Fong
    Wang, Congjun
    Craft, Daniel F.
    Kry, Stephen F.
    Lin, Stacy Sydney Hsinyi
    Garden, Adam S.
    Smith, Susan A.
    Howell, Rebecca M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03): : 89 - 96
  • [5] TOXICITY CRITERIA OF THE RADIATION-THERAPY ONCOLOGY GROUP (RTOG) AND THE EUROPEAN-ORGANIZATION-FOR-RESEARCH-AND-TREATMENT-OF-CANCER (EORTC)
    COX, JD
    STETZ, J
    PAJAK, TF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (05): : 1341 - 1346
  • [6] Material matters: Analysis of density uncertainty in 3D printing and its consequences for radiation oncology
    Craft, Daniel F.
    Kry, Stephen F.
    Balter, Peter
    Salehpour, Mohammad
    Woodward, Wendy
    Howell, Rebecca M.
    [J]. MEDICAL PHYSICS, 2018, 45 (04) : 1614 - 1621
  • [7] Dahn HM., 2021, Crit Rev Oncol Hematol, V163, P3
  • [8] A feasibility study of 2-mm bolus for postmastectomy radiation therapy
    Das, Lauren C.
    Golden, Daniel W.
    Perevalova, Eugenia
    Wong, Anthony C.
    De Nardo, Kimberly
    Stepaniak, Christopher
    Joyce, Daniel S.
    McCabe, Bradley P.
    Hasan, Yasmin
    Chmura, Steven J.
    McCall, Anne
    [J]. PRACTICAL RADIATION ONCOLOGY, 2017, 7 (03) : 161 - 166
  • [9] Dilson Lobo, 2022, Asian Pac J Cancer Prev, V23, P2973, DOI 10.31557/APJCP.2022.23.9.2973
  • [10] Dosimetric characterization of a rigid, surface-contour-specific thermoplastic bolus material
    Fagerstrom, Jessica M.
    [J]. MEDICAL DOSIMETRY, 2019, 44 (04) : 401 - 404