An Amperometric Biosensor Based on a Bilayer of Electrodeposited Graphene Oxide and Co-Crosslinked Tyrosinase for L-Dopa Detection in Untreated Human Plasma

被引:8
作者
Cembalo, Giuseppa [1 ]
Ciriello, Rosanna [1 ]
Tesoro, Carmen [1 ]
Guerrieri, Antonio [1 ]
Bianco, Giuliana [1 ]
Lelario, Filomena [1 ]
Acquavia, Maria Assunta [1 ]
Di Capua, Angela [1 ]
机构
[1] Univ Basilicata, Dipartimento Sci, Via Ateneo Lucano 10, I-85100 Potenza, Italy
关键词
L-Dopa; electrochemical detection; tyrosinase; co-crosslinking; graphene oxide; electrodeposition; human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; PARKINSONS-DISEASE; CAPILLARY-ELECTROPHORESIS; LEVODOPA; 3-O-METHYLDOPA; CARBIDOPA; BENSERAZIDE; ENTACAPONE; PLATINUM; SERUM;
D O I
10.3390/molecules28135239
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
L-Dopa, a bioactive compound naturally occurring in some Leguminosae plants, is the most effective symptomatic drug treatment for Parkinson's disease. During disease progression, fluctuations in L-DOPA plasma levels occur, causing motor complications. Sensing devices capable of rapidly monitoring drug levels would allow adjusting L-Dopa dosing, improving therapeutic outcomes. A novel amperometric biosensor for L-Dopa detection is described, based on tyrosinase co-crosslinked onto a graphene oxide layer produced through electrodeposition. Careful optimization of the enzyme immobilization procedure permitted to improve the long-term stability while substantially shortening and simplifying the biosensor fabrication. The effectiveness of the immobilization protocol combined with the enhanced performances of electrodeposited graphene oxide allowed to achieve high sensitivity, wide linear range, and a detection limit of 0.84 & mu;M, suitable for L-Dopa detection within its therapeutic window. Interference from endogenous compounds, tested at concentrations levels typically found in drug-treated patients, was not significant. Ascorbic acid exhibited a tyrosinase inhibitory behavior and was therefore rejected from the enzymatic layer by casting an outer Nafion membrane. The proposed device was applied for L-Dopa detection in human plasma, showing good recoveries.
引用
收藏
页数:16
相关论文
共 49 条
[1]   Wearable Electrochemical Sensors in Parkinson's Disease [J].
Asci, Francesco ;
Vivacqua, Giorgio ;
Zampogna, Alessandro ;
D'Onofrio, Valentina ;
Mazzeo, Adolfo ;
Suppa, Antonio .
SENSORS, 2022, 22 (03)
[2]   Towards wearable and implantable continuous drug monitoring: A review [J].
Bian, Sumin ;
Zhu, Bowen ;
Rong, Guoguang ;
Sawan, Mohamad .
JOURNAL OF PHARMACEUTICAL ANALYSIS, 2021, 11 (01) :1-14
[3]   A disposable electrochemical biosensor for L-DOPA determination in undiluted human serum [J].
Brunetti, Barbara ;
Valdes-Ramirez, Gabriela ;
Litvan, Irene ;
Wang, Joseph .
ELECTROCHEMISTRY COMMUNICATIONS, 2014, 48 :28-31
[4]   Determination of L-dopa, carbidopa, 3-O-methyldopa and entacapone in human plasma by HPLC-ED [J].
Bugamelli, F. ;
Marcheselli, C. ;
Barba, E. ;
Raggi, M. A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (03) :562-567
[5]  
Carbone ME, 2014, INT J ELECTROCHEM SC, V9, P2047
[6]   XPS investigation on the chemical structure of a very thin, insulating, film synthesized on platinum by electropolymerization of o-aminophenol (oAP) in aqueous solution at neutral pH [J].
Carbone, Maria Elvira ;
Ciriello, Rosanna ;
Guerrieri, Antonio ;
Salvi, Anna Maria .
SURFACE AND INTERFACE ANALYSIS, 2014, 46 (10-11) :1081-1085
[7]   Simultaneous quantitation of levodopa and 3-O-methyldopa in human plasma by HPLC-ESI-MS/MS: Application for a pharmacokinetic study with a levodopa/benserazide formulation [J].
Cesar, Isabela da Costa ;
Duarte Byrro, Ricardo Martins ;
de Santana e Silva Cardoso, Fabiana Fernandes ;
Mundim, Iram Moreira ;
Teixeira, Leonardo de Souza ;
da Silva, Enikson Pontes ;
Gomes, Sandro Antonio ;
Bonfim, Ricardo Rodrigues ;
Pianetti, Gerson Antonio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) :1094-1100
[8]   An Updated Review of Tyrosinase Inhibitors [J].
Chang, Te-Sheng .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2009, 10 (06) :2440-2475
[9]   Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application [J].
Chen, Liuyun ;
Tang, Yanhong ;
Wang, Ke ;
Liu, Chengbin ;
Luo, Shenglian .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (02) :133-137
[10]   Stability of ascorbic acid in serum and plasma prior to analysis [J].
Ching, SYL ;
Prins, AW ;
Beilby, JP .