Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom

被引:6
作者
Holmes, Thomas Wesley [1 ]
Yin, Zhye [2 ]
Stevens, Grant M. [2 ]
Slavic, Scott [2 ]
Okerlund, Darin R. [2 ]
Maltz, Jonathan S. [2 ]
Pourmorteza, Amir [1 ,3 ,4 ,5 ]
机构
[1] Emory Univ, Dept Radiol & Imaging Sci, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
[2] GE Healthcare, 3000 North Grandview Blvd, Waukesha, WI 53188 USA
[3] Emory Univ, Winship Canc Inst, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
[4] Emory Univ, Georgia Inst Technol, Dept Biomed Engn, 201 Dowman Dr, Atlanta, GA 30322 USA
[5] 1701 Uppergate Dr,Suite 5018A, Atlanta, GA 30322 USA
关键词
Photon-counting CT; Coronary angiography; Cardiac motion; Ultra-high-resolution CT; Virtual monoenergetic images; Stent characterization; COMPUTED-TOMOGRAPHY; CONTRAST AGENTS;
D O I
10.1016/j.jcct.2023.08.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent improvements in CT detector technology have led to smaller detector pixels resolving frequencies beyond 20 lp/cm and enabled ultra-high-resolution CT. Silicon-based photon-counting detector (PCD) CT is one such technology that promises improved spatial and spectral resolution. However, when the detector pixel sizes are reduced, the impact of cardiac motion on CT images becomes more pronounced. Here, we investigated the effects cardiac motion on the image quality of a clinical prototype Si-PCD scanner in a dynamic heart phantom.Methods: A series of 3D-printed vessels were created to simulate coronary arteries with diameter in the 1-3.5 mm range. Four coronary stents were set inside the d 1/4 3.5 mm vessels and all vessels were filled with contrast agents and were placed inside a dynamic cardiac phantom. The phantom was scanned in motion (60 bpm) and at rest on a prototype clinical Si-PCD CT scanner in 8-bin spectral UHR mode. Virtual monoenergetic images (VMI) were generated at 70 keV and CT number accuracy and effective spatial resolution (blooming) of rest and motion VMIs were compared.Results: Linear regression analysis of CT numbers showed excellent agreement (r > 0.99) between rest and motion. We did not observe a significant difference (p > 0.48) in estimating free lumen diameters. Differences in in-stent lumen diameter and stent strut thickness were non-significant with maximum mean difference of approximately 70 mu m.Conclusion: We found no significant degradation in CT number accuracy or spatial resolution due to cardiac motion. The results demonstrate the potential of spectral UHR coronary CT angiography enabled by Si-PCD.
引用
收藏
页码:341 / 344
页数:4
相关论文
共 50 条
[31]   Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study [J].
Zsarnoczay, Emese ;
Fink, Nicola ;
Schoepf, U. Joseph ;
Pinos, Daniel ;
O'Doherty, Jim ;
Allmendinger, Thomas ;
Hagenauer, Junia ;
Griffith III, Joseph P. ;
Vecsey-Nagy, Milan ;
Maurovich-Horvat, Pal ;
Emrich, Tilman ;
Varga-Szemes, Akos .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
[32]   Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study [J].
Dobrolinska, Magdalena M. ;
Koetzier, Lennart R. ;
Greuter, Marcel J. W. ;
Vliegenthart, Rozemarijn ;
van der Bie, Judith ;
Prakken, Niek H. J. ;
Slart, Riemer H. J. A. ;
Leiner, Tim ;
Budde, Ricardo P. J. ;
Mastrodicasa, Domenico ;
Booij, Ronald ;
Fleischmann, Dominik ;
Willemink, Martin J. ;
van Straten, Marcel ;
van der Werf, Niels R. .
EUROPEAN RADIOLOGY, 2024, 34 (11) :7429-7437
[33]   Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries [J].
Sartoretti, Thomas ;
McDermott, Michael C. ;
Stammen, Lion ;
Martens, Bibi ;
Moser, Lukas J. ;
Jost, Gregor ;
Pietsch, Hubertus ;
Gutjahr, Ralf ;
Nowak, Tristan ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Wildberger, Joachim E. ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2024, 59 (10) :677-683
[34]   Can Photon-Counting CT Improve Estimation Accuracy of Morphological Radiomics Features? A Simulation Study for Assessing the Quantitative Benefits from Improved Spatial Resolution in Deep Silicon-Based Photon-Counting CT [J].
Sharma, Shobhit ;
Pal, Debashish ;
Abadi, Ehsan ;
Sauer, Thomas ;
Segars, Paul ;
Hsieh, Jiang ;
Samei, Ehsan .
ACADEMIC RADIOLOGY, 2023, 30 (06) :1153-1163
[35]   Bicolor K-edge spectral photon-counting CT imaging for the diagnosis of thoracic endoleaks: A dynamic phantom study [J].
Cosset, Benoit ;
Sigovan, Monica ;
Boccalini, Sara ;
Farhat, Fadi ;
Douek, Philippe ;
Boussel, Loic ;
Si-Mohamed, Salim Aymeric .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (05) :235-242
[36]   Coronary atherosclerotic plaque characterization with silicon-based photon-counting computed tomography (CT): A simulation-based feasibility study [J].
Li, Mengzhou ;
Wu, Mingye ;
Pack, Jed ;
Wu, Pengwei ;
Yan, Pingkun ;
De Man, Bruno ;
Wang, Adam ;
Nieman, Koen ;
Wang, Ge .
MEDICAL PHYSICS, 2024, :8725-8741
[37]   Performance of calcium quantifications on low-dose photon-counting detector CT with high-pitch: A phantom study [J].
Zhou, Shanshui ;
Liu, Peng ;
Dong, Haipeng ;
Li, Jiqiang ;
Xu, Zhihan ;
Schmidt, Bernhard ;
Lin, Shushen ;
Yang, Wenjie ;
Yan, Fuhua ;
Qin, Le .
HELIYON, 2024, 10 (12)
[38]   Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement [J].
Vecsey-Nagy, Milan ;
Tremamunno, Giuseppe ;
Schoepf, U. Joseph ;
Gnasso, Chiara ;
Zsarnoczay, Emese ;
Fink, Nicola ;
Kravchenko, Dmitrij ;
Halfmann, Moritz C. ;
Laux, Gerald S. ;
O'Doherty, Jim ;
Szilveszter, Balint ;
Maurovich-Horvat, Pal ;
Kabakus, Ismail Mikdat ;
Suranyi, Pal Spruill ;
Varga-Szemes, Akos ;
Emrich, Tilman .
CIRCULATION-CARDIOVASCULAR IMAGING, 2024, 17 (10) :e017112
[39]   Ultrahigh-Resolution K-Edge Imaging of Coronary Arteries With Prototype Deep-Silicon Photon-Counting CT: Initial Results in Phantoms [J].
Holmes, Thomas Wesley ;
Yin, Zhye ;
Bujila, Robert ;
Madhav, Priti ;
Kim, Changlyong ;
Maltz, Jonathan S. ;
Pourmorteza, Amir .
RADIOLOGY, 2024, 311 (03)
[40]   Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector [J].
Simon, Judit ;
Hrenko, Aron ;
Kerkovits, Nora Melinda ;
Nagy, Kristof ;
Vertes, Miklos ;
Balogh, Hanna ;
Nagy, Norbert ;
Munkacsi, Tamas ;
Emrich, Tilman ;
Varga-Szemes, Akos ;
Boussoussou, Melinda ;
Vattay, Borbala ;
Vecsey-Nagy, Milan ;
Kolossvary, Marton ;
Szilveszter, Balint ;
Merkely, Bela ;
Maurovich-Horvat, Pal .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) :69-74