Accuracy and Reproducibility of Coronary Angiography-Derived Fractional Flow Reserve in the Assessment of Coronary Lesion Severity

被引:2
|
作者
Yang, Guojian [1 ]
Li, Le [1 ]
Peng, Xi [1 ]
Tang, Guodong [1 ]
Zheng, Naixin [1 ]
Zhao, Ying [1 ]
Li, Hui [1 ]
Zhang, Huiping [1 ]
Sun, Fucheng [1 ]
Ai, Hu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, 1 DaHua Rd, Beijing 100730, Peoples R China
来源
INTERNATIONAL JOURNAL OF GENERAL MEDICINE | 2023年 / 16卷
关键词
fractional flow reserve; computational flow dynamics; grey zone; diagnose; myocardial ischemia; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; STENOSIS; INTERVENTION; PERFORMANCE; INDEX; RATIO;
D O I
10.2147/IJGM.S413991
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Coronary angiography-derived fractional flow reserve (caFFR) is a novel computational flow dynamics (CFD)-derived assessment of coronary vessel flow with good diagnostic performance. Herein, we performed a retrospective study to evaluate the reproducibility of caFFR findings between observers and investigate the diagnostic performance of caFFR for coronary stenosis defined as FFR & LE;0.80, especially in the grey zone (0.75 & LE;caFFR & LE;0.80).Patients and Methods: A total of 150 patients (167 coronary vessels) underwent caFFR (with FlashAngio used for calculation of flow variables) and subsequent invasive fractional flow reserve (FFR) measurements. Outcomes, including reproducibility, were compared for vessels in and outside the grey zone.Results: The correlation of caFFR findings was good between the two laboratories (r = 0.723, p<0.001). The AUC of ROC were both high for caFFR-CoreLab1 and caFFR-CoreLab2 (0.975 and 0.883). The diagnostic accuracy, sensitivity, specificity, and negative and positive predictive values were not significantly different between the two laboratories (p>0.05). caFFR had a strong correlation with measures to FFR (r=0.911, p<0.001). There was no systematic difference between caFFR and FFR on Bland-Altman analysis in and outside the grey zone. There was no difference in diagnostic accuracy between the grey and non-grey zones in the prediction of FFR & LE;0.80 (p=0.09).Conclusion: The inter-observer reproducibility for caFFR was high, and the diagnostic accuracy of caFFR was good compared to that of FFR.
引用
收藏
页码:3805 / 3814
页数:10
相关论文
共 50 条
  • [21] Accuracy and reproducibility of fast fractional flow reserve computation from invasive coronary angiography
    van Rosendael, A. R.
    Koning, G.
    Dimitriu-Leen, A. C.
    Smit, J. M.
    Montero-Cabezas, J. M.
    van der Kley, F.
    Jukema, J. W.
    Reiber, J. H. C.
    Bax, J. J.
    Scholte, A. J. H. A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (09) : 1305 - 1312
  • [22] Fractional flow reserve derived from coronary CT angiography: Variation of repeated analyses
    Gaur, Sara
    Bezerra, Hiram G.
    Lassen, Jens F.
    Christiansen, Evald H.
    Tanaka, Kentaro
    Jensen, Jesper M.
    Oldroyd, Keith G.
    Leipsic, Jonathon
    Achenbach, Stephan
    Kaltoft, Anne K.
    Botker, Hans Erik
    Norgaard, Bjarne L.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 307 - 314
  • [23] Fractional flow reserve derived from routine coronary angiography
    Nishi, Takeshi
    Fearon, William F.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 271 : 51 - 52
  • [24] Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis
    Milovanovic, Aleksandar
    Isailovic, Velibor
    Saveljic, Igor
    Filipovic, Nenad
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) : 4613 - 4626
  • [25] Interpreting results of coronary computed tomography angiography-derived fractional flow reserve in clinical practice
    Rabbat, Mark G.
    Berman, Daniel S.
    Kern, Morton
    Raff, Gilbert
    Chinnaiyan, Kavitha
    Koweek, Lynne
    Shaw, Leslee J.
    Blanke, Philipp
    Scherer, Markus
    Jensen, Jesper M.
    Lesser, John
    Norgaard, Bjarne L.
    Pontone, Gianluca
    De Bruyne, Bernard
    Bax, Jeroen J.
    Leipsic, Jonathon
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (05) : 383 - 388
  • [26] Clinical Value of Computational Angiography-derived Fractional Flow Reserve in Stable Coronary Artery Disease
    Calvin Ka-Lam Leung
    Lok-Yee Lam
    Kwan-Yu Li
    Yundi Feng
    Gaozhen Cao
    Min Wu
    Run Wang
    Mei-Zhen Wu
    Qing-Wen Ren
    Si-Yeung Yu
    Yi-Kei Tse
    Hang-Long Li
    Shuk-Yin Yu
    Hung-Fat Tse
    Bo Xu
    Kai-Hang Yiu
    Journal of Cardiovascular Translational Research, 2023, 16 : 1166 - 1176
  • [27] The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values
    Xu, Cheng
    Xu, Min
    Yan, Jing
    Li, Yan-Yu
    Yi, Yan
    Guo, Yu-Bo
    Wang, Ming
    Li, Yu-Mei
    Jin, Zheng-Yu
    Wang, Yi-Ning
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7918 - 7926
  • [28] Diagnostic Accuracy of Computational Fluid Dynamics-Based Fractional Flow Reserve Derived From Coronary Angiography: The ACCURATE Study
    Jiang, Jun
    Hu, Yumeng
    Li, Changling
    Dong, Liang
    Xu, Jian
    Tang, Lijiang
    Jiang, Wenbing
    Du, Changqing
    Jiang, Xuejun
    Lyu, Yongnan
    Leng, Xiaochang
    Li, Chengguang
    Koo, Bon-Kwon
    Xiang, Jianping
    Ge, Junbo
    Wang, Jian'an
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2025, 14 (01):
  • [29] Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment
    Ninomiya, Kai
    Serruys, Patrick W.
    Kotoku, Nozomi
    Zhou, Jinying
    Kageyama, Shigetaka
    Masuda, Shinichiro
    Revaiah, Pruthvi C.
    Wang, Bo
    He, Xingqiang
    Tsai, Tsung-Ying
    Kageyama, Momoko
    Sevestre, Emelyne
    Sharif, Faisal
    Garg, Scot
    Akasaka, Takashi
    Escane, Javier
    Patel, Manesh R.
    Onuma, Yoshinobu
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (14) : 1778 - 1790
  • [30] Prognostic Implication of Computational Angiography-Derived Fractional Flow Reserve in Patients With Nonobstructive Coronary Artery Disease
    Hung, Yik-Ming
    Xuan, Hao-Chen
    Ren, Qing-Wen
    Huang, Jia-Yi
    Yu, Si-Yeung
    Tse, Yi-Kei
    Zhang, Jing-Nan
    Gu, Wen-Li
    Guo, Ran
    Leung, Calvin Ka-Lam
    Yiu, Kai-Hang
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2025, 14 (01):