A Fault-Tolerant Strategy for Safe Operation of Cascaded H-Bridge Multilevel Inverter Under Faulty Condition

被引:11
|
作者
Raki, Ashkan [1 ]
Neyshabouri, Yousef [2 ]
Aslanian, Mahdi [1 ]
Iman-Eini, Hossein [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, 1439957131, Tehran, Iran
[2] Urmia Univ, Fac Elect & Comp Engn, Orumiyeh 5756151818, Iran
关键词
Inverters; Voltage; Fault tolerant systems; Fault tolerance; Switches; Circuit faults; Multilevel inverters; Cascaded H-bridge (CHB) converter; fault-tolerant operation; multilevel inverter; CONVERTER; LOCALIZATION; STATCOM;
D O I
10.1109/TPEL.2023.3257278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the postfault operation of cascaded H-bridge (CHB) inverters, a CMV is injected into the phase voltages of the converter to achieve the maximum balanced line-to-line voltages. However, when the nonregenerative CHB inverter feeds a low power factor (PF) load, the FCMV may cause real power to return from the load to the dc side. On the other hand, when the inverter feeds a high PF load, the real power of some H-bridge cells may exceed the rated value. This article proposes a strategy consisting of two methods to tackle the mentioned problems. Also, three regions are determined, i.e., the nonoverload area, the nonreturnable power area, and the attainable zone for the FCMV. Then, a SOA is obtained by overlapping these regions. The first method (IMFCMV) determines the CMV waveform with the least possible FCMV. This avoids the power flow back; however, it does not guarantee the nonoverload operation of cells. So, it should be checked whether this FCMV is causing to overload operation of cells or not. If not, the proposed strategy uses the IMFCMV method. If yes, the second method (SFCMV) is used to shift FCMV into the SOA. In the SFCMV method, the determined CMV by the first method is modified so that its FCMV is located in the SOA. The simulation analysis and experimental results on the hardware prototype are provided to support the proposed strategy.
引用
收藏
页码:7285 / 7295
页数:11
相关论文
共 50 条
  • [41] Improvement of Post-Fault Performance of a Cascaded H-bridge Multilevel Inverter
    Ouni, Saeed
    Zolghadri, Mohammad Reza
    Khodabandeh, Masih
    Shahbazi, Mahmoud
    Rodriguez, Jose
    Oraee, Hashem
    Lezana, Pablo
    Ulloa Schmeisser, Andres
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (04) : 2779 - 2788
  • [42] A Generalized Modulation Strategy for a Cascaded H-Bridge Multilevel Inverter under Unequal DC Sources
    Lingom, Pascal
    Song-Manguelle, Joseph
    Betoka-Onyama, Simon Pierre
    Doumbia, Mamadou Lamine
    Nyobe-Yome, Jean Maurice
    Jin, Tao
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [43] Analysis of a cascaded multilevel inverter with fault-tolerant control
    Aguayo Alquicira, Jesus
    Claudio Sanchez, Abraham
    Vela Valdez, Luis Gerardo
    Antonio Rodriguez, Marco
    AmalioVargas Mendez, Rodolfo
    INGENIERIA E INVESTIGACION, 2011, 31 (03): : 66 - 79
  • [44] Voltage and Current Balancing of a Faulty Photovoltaic System Connected to Cascaded H-Bridge Multilevel Inverter
    Djermouni, Kamel
    Berboucha, Ali
    Tamalouzt, Salah
    Ziane, Djamel
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2024, 2024
  • [45] Fault-Tolerant Operation of Three-Phase Cascaded H-Bridge Converters Using an Auxiliary Module
    Salimian, Houshang
    Iman-Eini, Hossein
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (02) : 1018 - 1027
  • [46] Optimized control of modulation strategy for hybrid H-bridge cascaded multilevel inverter
    Zhang, Yun
    Sun, Li
    Zhao, Ke
    Wang, Yaoqiang
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (05): : 63 - 66
  • [47] A Multiple Fault-tolerant Multilevel Inverter with Hybrid Cascaded H-bridges
    Babu, Archin N.
    Anand, Anjali K.
    2022 IEEE 19TH INDIA COUNCIL INTERNATIONAL CONFERENCE, INDICON, 2022,
  • [48] Soft-switching modulation of the multilevel cascaded H-bridge inverter under DC source fault
    Xiong, Jinfei
    Zhou, Fulin
    Li, Qunzhan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (08) : 1337 - 1347
  • [49] A novel quasi-hot standby fault-tolerant control strategy for cascaded H-bridge rectifier
    Liao, Xin
    Wang, Shunliang
    Jiao, Ning
    Zhang, Rui
    Ma, Junpeng
    Liu, Tianqi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (15) : 3389 - 3398
  • [50] Improved n+l redundant fault-tolerant control strategy of cascaded H-bridge DSTATCOM
    Xu, Sheng
    Zhao, Jianfeng
    Xu, Xingtao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (07): : 54 - 59