A Fault-Tolerant Strategy for Safe Operation of Cascaded H-Bridge Multilevel Inverter Under Faulty Condition

被引:11
|
作者
Raki, Ashkan [1 ]
Neyshabouri, Yousef [2 ]
Aslanian, Mahdi [1 ]
Iman-Eini, Hossein [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, 1439957131, Tehran, Iran
[2] Urmia Univ, Fac Elect & Comp Engn, Orumiyeh 5756151818, Iran
关键词
Inverters; Voltage; Fault tolerant systems; Fault tolerance; Switches; Circuit faults; Multilevel inverters; Cascaded H-bridge (CHB) converter; fault-tolerant operation; multilevel inverter; CONVERTER; LOCALIZATION; STATCOM;
D O I
10.1109/TPEL.2023.3257278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the postfault operation of cascaded H-bridge (CHB) inverters, a CMV is injected into the phase voltages of the converter to achieve the maximum balanced line-to-line voltages. However, when the nonregenerative CHB inverter feeds a low power factor (PF) load, the FCMV may cause real power to return from the load to the dc side. On the other hand, when the inverter feeds a high PF load, the real power of some H-bridge cells may exceed the rated value. This article proposes a strategy consisting of two methods to tackle the mentioned problems. Also, three regions are determined, i.e., the nonoverload area, the nonreturnable power area, and the attainable zone for the FCMV. Then, a SOA is obtained by overlapping these regions. The first method (IMFCMV) determines the CMV waveform with the least possible FCMV. This avoids the power flow back; however, it does not guarantee the nonoverload operation of cells. So, it should be checked whether this FCMV is causing to overload operation of cells or not. If not, the proposed strategy uses the IMFCMV method. If yes, the second method (SFCMV) is used to shift FCMV into the SOA. In the SFCMV method, the determined CMV by the first method is modified so that its FCMV is located in the SOA. The simulation analysis and experimental results on the hardware prototype are provided to support the proposed strategy.
引用
收藏
页码:7285 / 7295
页数:11
相关论文
共 50 条
  • [31] Grid integration of three phase solar powered fault-tolerant cascaded H-bridge inverter
    Jami, Rajesh
    Nakka, Jayaram
    Pulavarthi, Satya Venkata Kishore
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2022, 50 (07) : 2566 - 2583
  • [32] State Of Charge Balancing during Fault Tolerant Operation of Battery Storage Systems Based on Cascaded H-Bridge Multilevel Inverter
    Herzog, Markus
    Ebentheuer, Andreas W.
    Herzog, Hans-Georg
    2019 FOURTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2019,
  • [33] A New Fault Tolerant Scheme for Cascaded H-Bridge Multilevel Converter
    Ouni, Saeed
    Noroozi, Negar
    Shahbazi, Mahmoud
    Zolghadri, MohammadReza
    Oraee, Hashem
    2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [34] A Controller for Cascaded H-Bridge Multilevel Inverter
    Kalla, Ujjwal Kumar
    Verma, Avanti
    Singh, Bhim
    Joshi, Keshav
    2016 IEEE 7TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2016,
  • [35] Fault detection and reconfiguration technique for cascaded H-bridge 11-level inverter drives operating under faulty condition
    Khomfoi, Surin
    Tolbert, Leon M.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 1228 - +
  • [36] Symmetric Cascaded H-Bridge Multilevel Inverter With Enhanced Multi-Phase Fault Tolerant Capability
    Neyshabouri, Yousef
    Monfared, Kourosh K.
    Iman-Eini, Hossein
    Farhadi-Kangarlu, Mohammad
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (09) : 8739 - 8750
  • [37] Study of Cascaded H-Bridge Multilevel Inverter
    Gaikwad, Asha
    Arbune, Pallavi Appaso
    2016 INTERNATIONAL CONFERENCE ON AUTOMATIC CONTROL AND DYNAMIC OPTIMIZATION TECHNIQUES (ICACDOT), 2016, : 179 - 182
  • [38] Fault-Tolerant Cascaded H-Bridge Converter for an Induction Motor Drive
    Sanz, I.
    Bueno, E. J.
    Moranchel, M.
    Rodriguez, F. J.
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 3980 - 3985
  • [39] Model Predictive-Based Fault-Tolerant and Power Balancing Control for Cascaded H-Bridge Inverter
    Wang, Xiaogang
    Zhao, Yongtian
    Yang, Ru
    Hu, Wei
    Zou, Tao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (05) : 5257 - 5270
  • [40] Fault-Tolerant Control of CPS-PWM-Based Cascaded Multilevel Inverter With Faulty Units
    Xiong, Liansong
    Zhuo, Fang
    Liu, Xiaokang
    Xu, Zhao
    Zhu, Yixin
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2019, 7 (04) : 2486 - 2497