A Wireless Power Transfer System Based on a Hybrid Transmitting Coil for Targeted Therapy Microrobots in the Intestine

被引:2
作者
Han, Ding [1 ,2 ]
Yan, Guozheng [1 ,2 ]
Wang, Zhiwu [1 ,2 ]
Jiang, Pingping [1 ,2 ]
Yan, Lin [3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Shanghai 200240, Peoples R China
[2] Shanghai Engn Res Ctr Intelligent Addict Treatment, Shanghai, Peoples R China
[3] Argonne Natl Lab, Environm Sci & Math & Comp Sci, Lemont, IL USA
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Wireless power transfer; Hybrid transmitting coil; Targeted therapy microrobots; Intestinal diseases detection; TRANSMISSION-SYSTEM; CAPSULE; DESIGN;
D O I
10.1007/s12541-023-00805-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A wireless power transfer system for targeted therapy microrobots has been received more attention recently. However, it usually fails to work due to weak coupling caused by misalignment in position and angle between the transmitting coil and the receiving coil. It will not be tolerated even if it occurs at certain angles. To address this issue, a three-dimensional hybrid transmitting coil, combining a fixed Helmholtz coil pair and an adjustable curved rectangular coil pair, is proposed. Based on the novel structure, the proposed hybrid transmitting coil could produce a three-dimensional magnetic field, realizing well coupled with the receiving coil embedded on the microrobot at any posture. To verify the efficiency and practical applicability of the transmitting coil proposed in this paper, we build the coil model via both analytical calculation and simulation analysis. Finally, the designed hybrid transmitting coil is also implemented in the wireless power transfer system with a receiving coil. The magnetic field distribution indicates that a large and uniform magnetic field could be obtained. The experimental results demonstrate that in the central zone of the transmitting coil, 300 x 200 mm, the magnetic field distribution is uniform, which can meet the requirements of the microrobot system working area. And the maximum output efficiency and power can be reached at 5% and 1001 mW, respectively. What's more, the proposed hybrid transmitting coil has solved the weak coupling problem due to misalignment in position and angle with which the electromagnetic energy decays quickly.
引用
收藏
页码:977 / 986
页数:10
相关论文
共 24 条
  • [11] Analytical Model and Optimized Design of Power Transmitting Coil for Inductively Coupled Endoscope Robot
    Ke, Quan
    Luo, Weijie
    Yan, Guozheng
    Yang, Kai
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (04) : 694 - 706
  • [12] Intermittent Embedding of Wire into 3D Prints for Wireless Power Transfer
    Kim, Chiyen
    Sullivan, Charlie
    Hillstrom, Alexander
    Wicker, Ryan
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2021, 22 (05) : 919 - 931
  • [13] Diagnostic accuracy of capsule endoscopy compared with colonoscopy for polyp detection: systematic review and meta-analyses
    Kjolhede, Tue
    Olholm, Anne Mette
    Kaalby, Lasse
    Kidholm, Kristian
    Qvist, Niels
    Baatrup, Gunnar
    [J]. ENDOSCOPY, 2021, 53 (07) : 713 - 721
  • [14] In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes
    Lay, Holly S.
    Cummins, Gerard
    Cox, Benjami F.
    Qiu, Yongqiang
    Turcanu, Mihnea Vlad
    McPhillips, Rachael
    Connor, Ciaran
    Gregson, Rachael
    Clutton, Eddie
    Desmulliez, Marc P. Y.
    Cochran, Sandy
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (03) : 632 - 639
  • [15] Robotics in the Gut
    Min, Jihong
    Yang, Yiran
    Wu, Zhiguang
    Gao, Wei
    [J]. ADVANCED THERAPEUTICS, 2020, 3 (04)
  • [16] Influences of Wire Diameters on Output Power in Electromagnetic Energy Harvester
    Peng, Yan
    Zhang, Lan
    Li, Zhongjie
    Zhong, Songyi
    Liu, Yong
    Xie, Shaorong
    Luo, Jun
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING-GREEN TECHNOLOGY, 2023, 10 (01) : 205 - 216
  • [17] Capsule robot for gut microbiota sampling using shape memory alloy spring
    Rehan, Muhammad
    Al-Bahadly, Ibrahim
    Thomas, David G.
    Avci, Ebubekir
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (05) : 1 - 14
  • [18] Three-dimensional power receiver for in vivo robotic capsules
    Ryu, Munho
    Kim, Jong Dae
    Chin, Hyun Uk
    Kim, Jongwon
    Song, Si Young
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (10) : 997 - 1002
  • [19] Long-term follow up of patients with obscure gastrointestinal bleeding examined with video capsule endoscopy
    Sealock, Robert J.
    Thrift, Aaron P.
    Ei-Serag, Hashem B.
    Sellin, Joseph
    [J]. MEDICINE, 2018, 97 (29)
  • [20] A portable wireless power transmission system for video capsule endoscopes
    Shi, Yu
    Yan, Guozheng
    Zhu, Bingquan
    Liu, Gang
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1721 - S1730