Energy-efficient fresh air system with pressure-independent dampers for nearly zero energy buildings

被引:9
|
作者
Lyu, Weihua [1 ,2 ]
Wang, Zhichao [1 ,2 ,5 ]
Li, Xiaofeng [3 ]
Yu, Zhen [1 ]
Yang, Yingxia [1 ,2 ]
Li, Jiandong [1 ,2 ]
Wang, Zhong [4 ]
Sun, Xiaoyu [1 ,2 ]
Sun, Guangzhao [1 ,2 ]
Han, Lichao [1 ,2 ]
Jing, Yan [1 ,2 ]
机构
[1] China Acad Bldg Res, Beijing, Peoples R China
[2] State Key Lab Bldg Safety & Built Environm, Beijing, Peoples R China
[3] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing, Peoples R China
[4] China Natl Accreditat Serv Conform Assessment, Beijing, Peoples R China
[5] China Acad Bldg Res, Beijing 100013, Peoples R China
关键词
Nearly zero energy building; Pressure-independent damper; Fresh air; Ventilation; Energy saving; NATURAL VENTILATION; RECOVERY VENTILATOR; HEAT; PERFORMANCE; TECHNOLOGIES; EXCHANGER; REGIONS; DESIGN; DEVICE;
D O I
10.1016/j.applthermaleng.2023.121240
中图分类号
O414.1 [热力学];
学科分类号
摘要
Fresh air volume control is of great significance in reducing energy consumption in nearly zero energy buildings. Previous studies have shown that the operating fresh air volume often deviates significantly from the design value, resulting in unnecessary energy consumption. To overcome this problem, this study proposes an energy efficiency fresh air system for NEBs by using pressure-independent dampers to balance system resistance and control the operating fresh air volume accurately. A typical fresh air system used in a typical NZEB was tested both in laboratory and on site for a whole heating season. Based on the test data, the energy consumption model of the proposed fresh air system was established and validated. The energy performance of the proposed system was analyzed comprehensively. Results show that using the pressure-independent damper in the fresh air system to control the fresh air flow rate can significantly reduce the fresh air load by 39.2%, 49.4%, 52.3% and 45.5% in Harbin, Beijing, Shanghai and Guangzhou, respectively; The annual energy saving rates in these cities are approximately 29.3%, 28.7%, 27.0% and 19.1%, respectively. These energy saving rates are smaller than the corresponding fresh air load reductions due to the additional energy consumption caused by the pressure-independent damper; Furthermore, replacing the pressure-independent damper with an ideal variable speed ventilator for fresh air flow rate control can further increase the energy saving rate by 12%similar to 16%. This study identifies the energy saving potential of fresh air systems and contributes to achieving sustainable development in nearly zero energy buildings.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Influential factors on the energy efficiency of fresh air systems in nearly zero energy buildings
    Lyu, Weihua
    Wang, Zhichao
    Li, Xiaofeng
    Yu, Zhen
    Sun, Xiaoyu
    Li, Jiandong
    ENERGY AND BUILDINGS, 2024, 313
  • [2] Energy-efficient heating control for nearly zero energy residential buildings with deep reinforcement learning
    Qin, Haosen
    Yu, Zhen
    Li, Tailu
    Liu, Xueliang
    Li, Li
    ENERGY, 2023, 264
  • [3] An Integrated Energy Management System for Nearly Zero Energy Buildings
    Jabbour, N.
    Tsioumas, E.
    Papagiannis, D.
    Koseoglou, M.
    Mademlis, C.
    7TH INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP 2019): RENEWABLE ENERGY RESOURCES IMPACT, 2019, : 259 - 265
  • [4] Energy Router Based Energy Management System for Nearly Zero Energy Buildings
    Najafzadeh, Mahdiyyeh
    Roasto, Indrek
    Jalakas, Tanel
    2019 IEEE 60TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2019,
  • [5] Review of energy conservation technologies for fresh air supply in zero energy buildings
    Liu, Zhongbing
    Li, Weijiao
    Chen, Yazhen
    Luo, Yongqiang
    Zhang, Ling
    APPLIED THERMAL ENGINEERING, 2019, 148 : 544 - 556
  • [6] Performance analysis of a thermoelectric air duct system for energy-efficient buildings
    Irshad, Kashif
    Habib, Khairul
    Thirumalaiswamy, Nagarajan
    Saha, Bidyut Baran
    ENERGY, 2015, 91 : 1009 - 1017
  • [7] Nearly-zero energy buildings
    Toftum, Jorn
    Baxter, Van
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (07) : 883 - 884
  • [8] ENERGY-EFFICIENT BUILDINGS
    ROSENFELD, AH
    HAFEMEISTER, D
    SCIENTIFIC AMERICAN, 1988, 258 (04) : 78 - &
  • [9] Energy system for nearly zero energy family buildings - Experience from operation
    Matuska, Tomas
    Sourek, Borivoj
    Broum, Michal
    ENERGY REPORTS, 2020, 6 : 117 - 123
  • [10] Embodied Energy and Nearly Zero Energy Buildings: A Review in Residential Buildings
    Chastas, P.
    Theodosiou, T.
    Bikas, D.
    Kontoleon, K.
    SUSTAINABLE SYNERGIES FROM BUILDINGS TO THE URBAN SCALE, 2017, 38 : 554 - 561