An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples

被引:15
作者
Ozyurt, Canan [1 ]
Uludag, Inci [2 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Lapseki Vocat Sch, Dept Chem & Chem Proc Technol, Canakkale, Turkey
[2] Canakkale Onsekiz Mart Univ, Engn Fac, Bioengn Dept, Canakkale, Turkey
关键词
Aptamer; Aptasensor; Prostate-specific antigen; Biosensor; Prostate cancer; Electrochemical impedance spectroscopy; APTAMER-BASED BIOSENSOR; FREE IMPEDIMETRIC APTASENSOR; CANCER; IMMUNOASSAY; POLYANILINE; ASSAYS;
D O I
10.1007/s00216-022-04309-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we constructed a disposable indium tin oxide polyethylene terephthalate film (ITO-PET)-based electrochemical aptasensor for analyzing prostate-specific antigen (PSA), one of the most important biomarkers of prostate cancer. Because of their clinical importance, building PSA biosensing systems with high sensitivity and stability is essential. However, it still presents significant difficulties, such as low detection limits. We designed a platform to covalently bind the amino-terminated aptamer by modifying the ITO-PET surface with carboxyethylsilanetriol (CTES) to obtain a self-assembled monolayer (SAM). We also evaluated the potential for use in real human serum samples by investigating the optimal operating conditions and analytical performance characteristics of the developed biosensor. The design we present here exhibits excellent precision, with a limit of detection (LOD) as low as 8.74 fg/mL PSA. The broad linear detection range of the biosensor under optimal conditions was determined as 1.0-1500 fg/mL. The dissociation constant (K-d) for the aptamer was also calculated as 46.28 +/- 5.63 nM by evaluating the impedimetric response as a function of PSA concentration. The aptasensor displayed considerable repeatability (1.3% RSD) and reproducibility (7.51% RSD) and good storage stability (98.34% of the initial activity for 8 weeks). Additionally, we demonstrated that the technique we developed was quite efficient in estimating the kinetics of aptamer-analyte interactions by determining the K-d and single-frequency impedance (SFI) data. In conclusion, we proposed a selective and sensitive biosensor with the potential for clinical application and superior performance in real serum samples.
引用
收藏
页码:1123 / 1136
页数:14
相关论文
共 62 条
[1]   The Effect of Aptamer Concetration towards Reduced Graphene Oxide-Field Effect Transistor Surface Channel for Biosensor Application [J].
Abidin, Azrul Syafiq Zainol ;
Rahim, Ruslinda Abdul ;
Huan, Chow Yong ;
Maidin, Nur Nasyifa Mohd ;
Ahmad, Nurul Atiqah ;
Hashwan, Saeed S. Ba ;
Faudzi, Fatin Nabilah Mohd ;
Hong, Voon Chun .
MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING AND TECHNOLOGY 2017 (MUCET 2017), 2018, 318
[2]  
Abu-Bakr El-Bayoumy Ahmed Sami, 2018, J Immunoassay Immunochem, V39, P12, DOI [10.1080/15321819.2017.1392320, 10.1080/15321819.2017.1392320]
[3]  
Adachi T, 1998, Hinyokika Kiyo, V44, P469
[4]   A novel biosensing system based on ITO-single use electrode for highly sensitive analysis of VEGF [J].
Akgun, Mert ;
Kemal Sezginturk, Mustafa .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) :432-450
[5]  
Armbruster DA., 2008, Clin Biochem Rev, V29, pS49, DOI DOI 10.3390/S20236922
[6]   Aptamersvs.antibodies as capture probes in optical porous silicon biosensors [J].
Arshavsky-Graham, Sofia ;
Urmann, Katharina ;
Salama, Rachel ;
Massad-Ivanir, Naama ;
Walter, Johanna-Gabriela ;
Scheper, Thomas ;
Segal, Ester .
ANALYST, 2020, 145 (14) :4991-5003
[7]   Targeting autophagy in prostate cancer: preclinical and clinical evidence for therapeutic response [J].
Ashrafizadeh, Milad ;
Paskeh, Mahshid Deldar Abad ;
Mirzaei, Sepideh ;
Gholami, Mohammad Hossein ;
Zarrabi, Ali ;
Hashemi, Farid ;
Hushmandi, Kiavash ;
Hashemi, Mehrdad ;
Nabavi, Noushin ;
Crea, Francesco ;
Ren, Jun ;
Klionsky, Daniel J. ;
Kumar, Alan Prem ;
Wang, Yuzhuo .
JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2022, 41 (01)
[8]   Influence of silane concentration on the silanization of multiwall carbon nanotubes [J].
Aviles, F. ;
Sierra-Chi, C. A. ;
Nistal, A. ;
May-Pat, A. ;
Rubio, F. ;
Rubio, J. .
CARBON, 2013, 57 :520-529
[9]   A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer [J].
Aydin, Elif Burcu ;
Sezginturk, Mustafa Kemal .
TALANTA, 2017, 172 :162-170
[10]   An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy [J].
Bahner, Nicole ;
Reich, Peggy ;
Frense, Dieter ;
Menger, Marcus ;
Schieke, Katharina ;
Beckmann, Dieter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (05) :1453-1462