Heterogeneous model to evaluate CFD in intracranial bifurcation aneurysms treated with the WEB device to predict angiographic outcome

被引:1
作者
Mantilla, Daniel [1 ,2 ,3 ,8 ]
Berod, Alain [4 ,5 ]
Ortiz, Andres F. [1 ,2 ]
Vera, Daniela D. [6 ]
Nicoud, Franck [5 ]
Costalat, Vincent [7 ]
机构
[1] Fdn oftalmol Santander Clin Ardila Lulle, Intervent Radiol Dept, Floridablanca, Colombia
[2] Univ Autonoma Bucaramanga, Intervent Radiol Dept, Bucaramanga, Colombia
[3] Univ Montpellier, Fac Sci, Montpellier, France
[4] Sim&Cure, Montpellier, France
[5] Univ Montpellier, Inst Montpellierain Alexander, Grothendieck, CNRS, Montpellier, France
[6] Fdn oftalmol Santander, Radiol Dept, Clin Ardila Lulle, Floridablanca, Colombia
[7] CHU Montpellier, Hop Gui de Chauliac, Neuroradiol, Montpellier, France
[8] Fdn oftalmol Santander Clin Ardila Lulle, Dept Intervent Radiol, Calle 157 20-59,Floor Zero,Off 07, Floridablanca, Santander, Colombia
关键词
Aneurysm; hemodynamics; intra-saccular device; intrasaccular flow diverter; fluid dynamic; CEREBRAL ANEURYSMS; DYNAMICS; HEMODYNAMICS; RUPTURE;
D O I
10.1177/15910199231152514
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction The Woven EndoBridge device (WEB) was developed as an alternative to treat Wide-Necked bifurcation aneurysms. It has proven to be effective and safe, however, cases of recanalization have been reported. The purpose of this study was to evaluate and quantify hemodynamic parameters and indexes with CFD of the intracranial aneurysms before and after WEB simulation and to establish their relationship to complete occlusion. Materials and methods Using the heterogeneous model based on the marching cubes algorithm, we created 3D representations of 27 bifurcated intracranial aneurysms treated with the single-layer WEB device to evaluate hemodynamics parameters with CFD, calculated with and without the WEB. Results We observed a lower treatment entry concentration indices (ICI) (2.12 +/- 1.31 versus 3.14 +/- 0.93, p-value: 0.029) previous to placement of WEB and higher pre-treatment FN (7.56 +/- 5.92 versus 3.35 +/- 1.51, p-value: 0.018) and post-treatment FN (5.34 +/- 5.89 versus 1.99 +/- 0.83, p-value: 0.021) for cases with successful occlusions. Lower post-treatment SRa (197.81 +/- 221.29 versus 80.02 +/- 45.25, p-value: 0.044) and higher pre (0.11 +/- 0.07 versus 0.25 +/- 0.19, p-value: 0.011) and post-treatment MATT (0.69 +/- 1.23 versus 1.02 +/- 0.46, p-value: 0.006) were observed in non-occluded cases. Conclusions In our CFD analysis of the hemodynamic parameters of IA, we found lower ICI before the placement of the WEB device and higher FN pre- and post-treatment for cases with successful occlusions. Non-occluded cases had lower post-treatment SRa and higher pre-treatment and post-treatment MATT.
引用
收藏
页数:9
相关论文
共 21 条
  • [1] Berod A., 2021, MODELISATION IN SILI
  • [2] Cagnazzo F., 2020, J NEURORADIOLOGY, V47, P104
  • [3] Single-Layer WEBs: lntrasaccular Flow Disrupters for Aneurysm Treatment-Feasibility Results from a European Study
    Caroff, J.
    Mihalea, C.
    Klisch, J.
    Strasilla, C.
    Berlis, A.
    Patankar, T.
    Weber, W.
    Behme, D.
    Jacobsen, E. A.
    Liebig, T.
    Prothmann, S.
    Cognard, C.
    Finkenzeller, T.
    Moret, J.
    Spelle, L.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) : 1942 - 1946
  • [4] A computational fluid dynamics (CFD) study of WEB-treated aneurysms: Can CFD predict WEB "compression" during follow-up?
    Caroff, Jildaz
    Mihalea, Cristian
    Da Ros, Valerio
    Yagi, Takanobu
    Iacobucci, Marta
    Ikka, Leon
    Moret, Jacques
    Spelle, Laurent
    [J]. JOURNAL OF NEURORADIOLOGY, 2017, 44 (04) : 262 - 268
  • [5] Flow-area relationship in internal carotid and vertebral arteries
    Cebral, J. R.
    Castro, M. A.
    Putman, C. M.
    Alperin, N.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (05) : 585 - 594
  • [6] Analysis of Flow Dynamics and Outcomes of Cerebral Aneurysms Treated with Intrasaccular Flow-Diverting Devices
    Cebral, J. R.
    Chung, B. J.
    Mut, F.
    Chudyk, J.
    Bleise, C.
    Scrivano, E.
    Lylyk, P.
    Kadirvel, R.
    Kallmes, D.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (09) : 1511 - 1516
  • [7] Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
  • [8] Errors in power-law estimations of inflow rates for intracranial aneurysm CFD
    Chnafa, C.
    Bouillot, P.
    Brina, O.
    Najafi, M.
    Delattre, B. M. A.
    Vargas, M. I.
    Pereira, V. M.
    Steinman, D. A.
    [J]. JOURNAL OF BIOMECHANICS, 2018, 80 : 159 - 165
  • [9] What is the hemodynamic effect of the Woven EndoBridge? An in vivo quantification using time-density curve analysis
    Goelitz, Philipp
    Luecking, Hannes
    Hoelter, Philip
    Knossalla, Frauke
    Doerfler, Arnd
    [J]. NEURORADIOLOGY, 2020, 62 (08) : 1043 - 1050
  • [10] How to WEB: a practical review of methodology for the use of the Woven EndoBridge
    Goyal, Nitin
    Hoit, Daniel
    DiNitto, Julie
    Elijovich, Lucas
    Fiorella, David
    Pierot, Laurent
    Lamin, Saleh
    Spelle, Laurent
    Saatci, Isil
    Cekirge, Saru
    Arthur, Adam S.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (05) : 512 - 520