Fabrication of three-dimensional orthodontic force detecting brackets and preliminary clinical test for tooth movement simulation

被引:3
作者
Xie, Qianyang [1 ]
Li, Peilun [1 ]
Zhou, Zhitao [1 ,2 ]
Bai, Guo [1 ]
Sun, Ke [2 ]
Li, Xinxin [1 ,2 ]
Yang, Heng [1 ,2 ,4 ]
Zou, Duohong [1 ,3 ]
Yang, Chi [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Peoples Hosp 9, Sch Med, Coll Stomatol,Shanghai Res Inst Stomatol,Shanghai, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol SIMIT, 865 Changning Rd, Shanghai 200050, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Peoples Hosp 9, Dept Oral Surg, 639 Zhizaoju Rd, Shanghai 200011, Peoples R China
[4] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol SIMIT, 865 Changning Rd, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
Force detection bracket; Pressure sensor; In vivo force measurement; Mechanical simulation model; Tooth movement; ROOT RESORPTION;
D O I
10.1016/j.heliyon.2023.e19852
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to develop an ultraminiature pressure sensor array to measure the force exerted on teeth. Orthodontic force plays an important role in effective, rapid, and safe tooth movement. However, owing to the lack of an adequate tool to measure the orthodontic force in vivo, it remains challenging to determine the best orthodontic loading in clinical and basic research. In this study, a three-dimensional (3D) orthodontic force detection system based on piezoresistive absolute pressure sensors was designed. The 3D force sensing array was constructed using five pressure sensors on a single chip. The size of the sensor array was only 4.1 x 2.6 mm, which can be placed within the bracket base area. Based on the barometric calibration, conversion formulas for the output voltage and pressure of the five channels were constructed. Subsequently, a 3D linear mechanical simulation model of the voltage and stress distribution was established using 312 tests of the applied force in 13 operating modes. Finally, the output voltage was first converted to pressure and then to the resultant force. The 3D force-detection chip was then tested to verify the accuracy of force measurement on the teeth. Based on the test results, the average output force error was only 0.0025 N (0.7169%) (p = 0.958), and the average spatial positioning error was only 0.058 mm (p = 0.872) on the X-axis and 0.050 mm (p = 0.837) on the Y-axis. The simulation results were highly consistent with the actual force applied (intraclass correlation efficient (ICC): 0.997-1.000; p < 0.001). Furthermore, through in vivo measurements and a finite element analysis, the movement trends generated when the measured orthodontic forces that acted on the teeth were simulated. The results revealed that the device can accurately measure the orthodontic force, representing the first clinical test of an orthodontic-force monitoring system. Our study provides a hardware basis for clinical research on efficient, safe, and optimal orthodontic forces, and has considerable potential for application in monitoring the biomechanics of tooth movement.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial [J].
Abraham, William T. ;
Adamson, Philip B. ;
Bourge, Robert C. ;
Aaron, Mark F. ;
Costanzo, Maria Rosa ;
Stevenson, Lynne W. ;
Strickland, Warren ;
Neelagaru, Suresh ;
Raval, Nirav ;
Krueger, Steven ;
Weiner, Stanislav ;
Shavelle, David ;
Jeffries, Bradley ;
Yadav, Jay S. .
LANCET, 2011, 377 (9766) :658-666
[2]   Genetic predisposition to external apical root resorption in orthodontic patients: Linkage of chromosome-18 marker [J].
Al-Qawasmi, RA ;
Hartsfield, JK ;
Everett, ET ;
Flury, L ;
Liu, L ;
Foroud, TM ;
Macri, JV ;
Roberts, WE .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) :356-360
[3]   Orthodontic mechanotherapies and their influence on external root resorption: A systematic review [J].
Currell, Scott Derek ;
Liaw, Andrew ;
Grant, Peter Donald Blackmore ;
Esterman, Adrian ;
Nimmo, Alan .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 155 (03) :313-329
[4]   Evaluation of root resorption after comprehensive orthodontic treatment using cone beam computed tomography (CBCT): a meta-analysis [J].
Deng, Yaqi ;
Sun, Yannan ;
Xu, Tianmin .
BMC ORAL HEALTH, 2018, 18
[5]   Reduced bacterial adhesion with parylene coating: Potential implications for Micra transcatheter pacemakers [J].
El-Chami, Mikhael F. ;
Mayotte, Jane ;
Bonner, Matt ;
Holbrook, Reece ;
Stromberg, Kurt ;
Sohail, Muhammad Rizwan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (03) :712-717
[6]   Measurement of root surface area of permanent teeth in a Chinese population [J].
Gu, Y. ;
Zhu, Q. ;
Tang, Y. ;
Zhang, Y. ;
Feng, X. .
ARCHIVES OF ORAL BIOLOGY, 2017, 81 :26-30
[7]   A review of wearable and unobtrusive sensing technologies for chronic disease management [J].
Guo, Yao ;
Liu, Xiangyu ;
Peng, Shun ;
Jiang, Xinyu ;
Xu, Ke ;
Chen, Chen ;
Wang, Zeyu ;
Dai, Chenyun ;
Chen, Wei .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
[8]  
Hafner J, 2018, IEEE SENSOR, P574, DOI 10.1109/ICSENS.2018.8589619
[9]   Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study [J].
Inoue, Sayuri ;
Yamaguchi, Satoshi ;
Uyama, Hiroshi ;
Yamashiro, Takashi ;
Imazato, Satoshi .
MATERIALS, 2020, 13 (18)
[10]   Influence of constant strain on the elasticity of thermoplastic orthodontic materials [J].
Inoue, Sayuri ;
Yamaguchi, Satoshi ;
Uyama, Hiroshi ;
Yamashiro, Takashi ;
Imazato, Satoshi .
DENTAL MATERIALS JOURNAL, 2020, 39 (03) :415-421