Electrostatically-driven self-assembly of copper nanoclusters and carbon dots for quantitative protamine and heparin determination

被引:16
作者
Alkahtani, Saad A. [1 ]
Mahmoud, Ashraf M. [2 ]
Mohamed, Rasha M. K. [3 ]
El-Wekil, Mohamed M. [4 ]
机构
[1] Najran Univ, Coll Pharm, Dept Clin Pharm, Najran, Saudi Arabia
[2] Najran Univ, Coll Pharm, Dept Pharmaceut Chem, Najran, Saudi Arabia
[3] Jouf Univ, Coll Sci, Dept Chem, POB 2014, Sakaka, Saudi Arabia
[4] Assiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Assiut, Egypt
关键词
Protamine; Heparin; Cationic carbon dots; GSH-CuNCs; Self-assembly; Electrostatic interaction; INFRARED SPECTROSCOPIC METHOD; AGGREGATION-INDUCED EMISSION; RATIOMETRIC FLUORESCENCE; SENSITIVE DETECTION; CU NANOCLUSTERS; BINARY; PROBE;
D O I
10.1016/j.microc.2023.109404
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel nanosystem composed of red-emissive thiolate-capped copper nanoclusters (GSH-CuNCs) and blueemissive polyethyleneimine-tailored carbon dots (B-CDs+) was utilized for the quantitative determination of protamine and heparin. Addition of B-CDs+ to a solution containing GSH-CuNCs resulted in a significant increase in the fluorescence emission of GSH-CuNCs due to their self-assembly through an electrostatic interaction. However, in the presence of protamine, a polycationic protein, the fluorescence emission of GSH-CuNCs at 590 nm was decreased as a result of adsorbing protamine on GSH-CuNCs surface instead of B-CDs+. This led to disassembling of GSH-CuNCs, while the fluorescence emission of B-CDs+ at 470 nm remained unchanged during the determination. In the presence of heparin, a negatively charged molecule, the fluorescence emission of GSHCuNCs nanosystem was recovered due to strong electrostatic interaction between protamine and heparin. The displaced B-CDs+ aggregated the GSH-CuNCs, restoring its fluorescence emission. Under optimized conditions, the fluorescence responses were increased with the protamine and heparin concentrations in the range of 0.004-40 mu g/mL and 0.01-28 mu g/mL, with LODs (S/N = 3) of 0.001 mu g/mL and 0.004 mu g/mL, respectively. The nanosystem offers several merits, including an ultra-low LODs, wide dynamic linear range, good antiinterference, satisfactory detection reliability, and short response time. Importantly, this strategy was successfully devoted to estimate protamine and heparin in urine and serum samples, and the results were found to be acceptable.
引用
收藏
页数:8
相关论文
共 44 条
[11]   Melamine-Induced Decomposition and Anti-FRET Effect from a Self-Assembled Complex of Rhodamine 6G and DNA-Stabilized Silver Nanoclusters Used for Dual-Emitting Ratiometric and Naked-Eye-Visible Fluorescence Detection [J].
Fu, Yongxin ;
Jin, Hui ;
Bu, Xiangning ;
Gui, Rijun .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (37) :9819-9827
[12]   Ratiometric fluorescence, solution-phase and filter-paper visualization detection of ciprofloxacin based on dual-emitting carbon dot/silicon dot hybrids [J].
Gui, Rijun ;
Bu, Xiangning ;
He, Weijie ;
Jin, Hui .
NEW JOURNAL OF CHEMISTRY, 2018, 42 (19) :16217-16225
[13]   Ultra-stable L-proline protected copper nanoclusters and their solvent effect [J].
Han, Bingyan ;
Peng, Tingting ;
Li, Ying ;
Yu, Mingbo ;
Hu, Xixi ;
He, Gaohong .
METHODS AND APPLICATIONS IN FLUORESCENCE, 2018, 6 (03)
[14]   One-step rapid synthesis of single thymine-templated fluorescent copper nanoclusters for "turn on" detection of Mn2+ [J].
Han, Bingyan ;
Xiang, Rongchao ;
Hou, Xufen ;
Yu, Mingbo ;
Peng, Tingting ;
Li, Ying ;
He, Gaohong .
ANALYTICAL METHODS, 2017, 9 (17) :2590-2595
[15]   Ratiometric fluorescence and visual imaging detection of dopamine based on carbon dots/copper nanoclusters dual-emitting nanohybrids [J].
He, Weijie ;
Gui, Rijun ;
Jin, Hui ;
Wang, Benqian ;
Bu, Xiangning ;
Fu, Yongxin .
TALANTA, 2018, 178 :109-115
[16]   Heparin and low-molecular-weight heparin - The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy [J].
Hirsh, J ;
Raschke, R .
CHEST, 2004, 126 (03) :188S-203S
[17]   Transfusion of Plasma, Platelets, and Red Blood Cells in a 1:1:1 vs a 1:1:2 Ratio and Mortality in Patients With Severe Trauma The PROPPR Randomized Clinical Trial [J].
Holcomb, John B. ;
Tilley, Barbara C. ;
Baraniuk, Sarah ;
Fox, Erin E. ;
Wade, Charles E. ;
Podbielski, Jeanette M. ;
del Junco, Deborah J. ;
Brasel, Karen J. ;
Bulger, Eileen M. ;
Callcut, Rachael A. ;
Cohen, Mitchell Jay ;
Cotton, Bryan A. ;
Fabian, Timothy C. ;
Inaba, Kenji ;
Kerby, Jeffrey D. ;
Muskat, Peter ;
O'Keeffe, Terence ;
Rizoli, Sandro ;
Robinson, Bryce R. H. ;
Scalea, Thomas M. ;
Schreiber, Martin A. ;
Stein, Deborah M. ;
Weinberg, Jordan A. ;
Callum, Jeannie L. ;
Hess, John R. ;
Matijevic, Nena ;
Miller, Christopher N. ;
Pittet, Jean-Francois ;
Hoyt, David B. ;
Pearson, Gail D. ;
Leroux, Brian ;
van Belle, Gerald .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (05) :471-482
[18]   Copper nanocluster-based fluorescent probe for sensitive and selective detection of Hg2+ in water and food stuff [J].
Hu, Xue ;
Wang, Wei ;
Huang, Yuming .
TALANTA, 2016, 154 :409-415
[19]   A CRISPR-enabled fluorometric biosensor for the sensitive detection of heparin antidote protamine based on programmable nuclease Cas12a [J].
Ji, Zhirun ;
Shang, Zhaoyang ;
Sohail, Muhammad ;
Wang, Pei ;
Li, Bingzhi ;
Zhang, Xing ;
Chen, Guoxiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2023, 374
[20]   Copper(II)-mediated sliver nanoclusters as a fluorescent platform for highly sensitive detection of alendronate sodium [J].
Jia, Chunyan ;
Shang, Jingchuan ;
Wang, Yi ;
Bai, Lijuan ;
Tong, Chao ;
Chen, Yongjie ;
Zhang, Pu .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 269 :271-277