Hypoattenuated Leaflet Thickening After Implantation of the ACURATE neo or the ACURATE neo2 Transcatheter Heart Valve

被引:3
|
作者
Brunner, Stephanie [1 ]
Brinkert, Miriam [2 ]
Moccetti, Federico [1 ]
Loretz, Lucca [1 ]
Fornaro, Jurgen [3 ]
Stampfli, Simon F. [1 ]
Attinger-Toller, Adrian [1 ]
Bossard, Matthias [1 ]
Buhmann, Ralf [3 ]
Cuculi, Florim [1 ]
Wolfrum, Mathias [1 ]
Toggweiler, Stefan [1 ]
机构
[1] Luzerner Kantonsspital, Heart Ctr Lucerne, Cardiol Div, Luzern, Switzerland
[2] Kantonsspital Aarau, Dept Cardiol, Aarau, Switzerland
[3] Luzerner Kantonsspital, Dept Radiol, Luzern, Switzerland
来源
关键词
AORTIC REGURGITATION; COMPUTED-TOMOGRAPHY; THROMBOSIS; REPLACEMENT; PREDICTORS; OUTCOMES;
D O I
10.1016/j.amjcard.2023.05.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Subclinical leaflet thrombosis, identified as hypoattenuated leaflet thickening (HALT) on cardiac computed tomography scan, has been observed after transcatheter aortic valve ACURATE neo/neo2 prosthesis are limited. This study aimed to determine the prevalence and risk factors for the development of HALT after TAVR with the ACURATE neo/neo2. A total of 50 patients who received the ACURATE neo/neo2 prosthesis were prospectively enrolled. Patients underwent a contrast-enhanced multidetector row cardiac computed tomography scan at before, after, and 6 months after TAVR. At the 6-month follow-up, HALT was detected in 16% (8 of 50 patients). These patients had a lower implant depth of the transcatheter heart valve (8 & PLUSMN; 2 mm vs 5 & PLUSMN; 2 mm, p = 0.001), less calcified native valve leaflets, a better expansion of the frame at the level of the left ventricular outflow tract, and were less often hypertensive. Thrombosis of the sinus of Valsalva occurred in 18% (9/50). There was no difference in the anticoagulation regimen between patients with and without thrombotic findings. In conclusion, HALT was present in 16% of patients at 6 months follow-up, patients presenting with HALT had a lower implant depth of the transcatheter heart valve, and HALT was detected in patients on oral anticoagulation therapy. & COPY; 2023 Elsevier Inc. All rights reserved. (Am J Cardiol 2023;200:146-152)
引用
收藏
页码:146 / 152
页数:7
相关论文
共 50 条
  • [1] Paravalvular Leak After Implantation of the ACURATE neo and the ACURATE neo2 Transcatheter Heart Valve
    Toggweiler, Stefan
    Brinkert, Miriam
    Wolfrum, Mathias
    Moccetti, Federico
    Stampfli, Simon F.
    De Boeck, Bart W. L.
    Magarzo, Getulio
    Gassenmaier, Tobias
    Attinger-Toller, Adrian
    Bossard, Matthias
    Fornaro, Jurgen
    Buhmann, Ralf
    Cuculi, Florim
    Kobza, Richard
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 45 : 37 - 43
  • [2] ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty- direct ACURATE neo2
    Elkoumy, Ahmed
    Ruck, Andreas
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Abdelshafy, Mahmoud
    Arsang-Jang, Shahram
    Elzomor, Hesham
    Laine, Mika
    Bjursten, Henrik
    Gotberg, Matthias
    Wykrzykowska, Joanna J.
    Mohamed, Sameh K.
    Pellegrini, Costanza
    Rheude, Tobias
    Toggweiler, Stefan
    Saleh, Nawzad
    Meduri, Christopher U.
    Kim, Won-Keun
    Soliman, Osama
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 400
  • [3] ACURATE neo2 Implantation Without Balloon Predilatation (Direct ACURATE neo2)
    Elkoumy, Ahmed
    Ruck, Andreas
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja
    Wolf, Alexander
    De Backer, Ole
    Hengstenberg, Christian
    Bjursten, Henrik
    Gotberg, Matthias
    Wykrzykowska, Joanna
    Saleh, Nawzad
    Meduri, Christopher
    Kim, Won-Keun
    Soliman, Osama
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B190 - B191
  • [4] The ACURATE neo™ and neo2™ Valve Systems
    Reardon, Michael J.
    HEART INTERNATIONAL, 2021, 15 (01): : 37 - 41
  • [5] The Early neo2 Registry: Transcatheter Aortic Valve Implantation With ACURATE neo2 in a European Population
    Rueck, Andreas
    Kim, Won-Keun
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Laine, Mika
    Miyashita, Hirokazu
    Bjursten, Henrik
    Goetberg, Matthias
    Pellegrini, Costanza
    Toggweiler, Stefan
    Wykrzykowska, Joanna J.
    Soliman, Osama
    Saleh, Nawzad
    Meduri, Christopher U.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (15):
  • [6] Comparison of the Acurate Neo Vs Neo2 Transcatheter Heart Valves
    Kim, Won-Keun
    Eckel, Clemens
    Renker, Matthias
    Grothusen, Christina
    Tiyerili, Vedat
    Soetemann, Dagmar
    Choi, Yeong-Hoon
    Hamm, Christian W.
    Moellmann, Helge
    Charitos, Efstratios I.
    Blumenstein, Johannes
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (11): : E804 - E810
  • [7] Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice: one-year results of the ACURATE neo2 PMCF Study
    Kim, Won-Keun
    Moellmann, Helge
    Montorfano, Matteo
    Ellert-Gregersen, Julia
    Rudolph, Tanja K.
    Van Mieghem, Nicolas M.
    Hilker, Michael
    Amat-Santos, Ignacio
    Terkelsen, Christian Juhl
    Petronio, Anna Sonia
    Stella, Pieter
    Goetberg, Matthias
    Rueck, Andreas
    Kasel, A. Markus
    Trillo, Ramiro
    Appleby, Clare
    Barbanti, Marco
    Blanke, Philipp
    Asch, Federico M.
    Modolo, Rodrigo
    Allocco, Dominic J.
    Tamburino, Corrado
    EUROINTERVENTION, 2024, 20 (01) : 85 - 94
  • [8] Paravalvular Aortic Regurgitation Severity Assessed by Quantitative Aortography: ACURATE neo2 versus ACURATE neo Transcatheter Aortic Valve Implantation
    Ruck, Andreas
    Kim, Won-Keun
    Kawashima, Hideyuki
    Abdelshafy, Mahmoud
    Elkoumy, Ahmed
    Elzomor, Hesham
    Wang, Rutao
    Meduri, Christopher U.
    Verouhis, Dinos
    Saleh, Nawzad
    Onuma, Yoshinobu
    Mylotte, Darren
    Serruys, Patrick W.
    Soliman, Osama
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)
  • [9] Transcatheter Aortic Valve Replacement With Self-Expanding Acurate Neo2 Valve Versus Acurate Neo Valve: A Meta-Analysis
    Aggarwal, Gaurav
    Haddad, Toufik Mahfood
    Bansal, Sakshi
    Aggarwal, Saurabh
    Umeh, Chikwuemeka
    Gokhroo, Rahul
    Agarwal, Himanshu
    Narmi, Ann E.
    Reddy, Arun Kanmantha
    DelCore, Michael G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S88 - S89
  • [10] Technical Considerations for Transcatheter Aortic Valve Replacement With ACURATE neo2
    Wong, Ivan
    Bieliauskas, Gintautas
    De Backer, Ole
    Sondergaard, Lars
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 224 - 226