Improved differentiation between hypo/hypertelorism and normal fetuses based on MRI using automatic ocular biometric measurements, ocular ratios, and machine learning multi-parametric classification

被引:4
作者
Avisdris, Netanell [1 ,2 ]
Sourani, Daphna Link [1 ]
Ben-Sira, Liat [3 ,4 ,5 ]
Joskowicz, Leo [2 ]
Malinger, Gustavo [4 ,6 ]
Yagel, Simcha [7 ]
Miller, Elka [8 ]
Ben Bashat, Dafna [1 ,4 ,5 ]
机构
[1] Tel Aviv Sourasky Med Ctr, Sagol Brain Inst, Tel Aviv, Israel
[2] Hebrew Univ Jerusalem, Sch Comp Sci & Engn, Jerusalem, Israel
[3] Tel Aviv Sourasky Med Ctr, Div Pediat Radiol, Tel Aviv, Israel
[4] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[5] Tel Aviv Univ, Sagol Sch Neurosci, Tel Aviv, Israel
[6] Lis Matern Hosp, Div Ultrasound Obstet & Gynecol, Tel Aviv, Israel
[7] Hadassah Hebrew Univ Med Ctr, Obstet & Gynecol Div, Jerusalem, Israel
[8] Univ Ottawa, Med Imaging Dept, CHEO, Ottawa, ON, Canada
关键词
Deep learning; Hypertelorism; Fetus; Biometry; Magnetic resonance imaging; GOLDEN RATIO; FETAL;
D O I
10.1007/s00330-022-08976-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To differentiate hypo-/hypertelorism (abnormal) from normal fetuses using automatic biometric measurements and machine learning (ML) classification based on MRI. Methods MRI data of normal (n = 244) and abnormal (n = 52) fetuses of 22-40 weeks' gestational age (GA), scanned between March 2008 and June 2020 on 1.5/3T systems with various T-2-weighted sequences and image resolutions, were included. A fully automatic method including deep learning and geometric algorithms was developed to measure the binocular (BOD), inter-ocular (IOD), ocular (OD) diameters, and ocular volume (OV). Two new parameters, BOD-ratio and IOD-ratio, were defined as the ratio between BOD/IOD relative to the sum of both globes' OD, respectively. Eight ML classifiers were evaluated to detect abnormalities using measured and computed parameters. Results The automatic method yielded a mean difference of BOD = 0.70 mm, IOD = 0.81 mm, OD = 1.00 mm, and a 3D-Dice score of OV = 93.7%. In normal fetuses, all four measurements increased with GA. Constant values were detected for BOD-ratio = 1.56 +/- 0.05 and IOD-ratio = 0.60 +/- 0.05 across all GA and when calculated from previously published reference data of both MRI and ultrasound. A random forest classifier yielded the best results on an independent test set (n = 58): AUC-ROC = 0.941 and F-1-Score = 0.711 in comparison to AUC-ROC = 0.650 and F-1-Score = 0.385 achieved based on the accepted criteria that define hypo/hypertelorism based on IOD (< 5(th) or > 95(th) percentiles). Using the explainable ML method, the two computed ratios were found as the most contributing parameters. Conclusions The developed fully automatic method demonstrates high performance on varied clinical imaging data. The new BOD and IOD ratios and ML multi-parametric classifier are suggested to improve the differentiation of hypo-/hypertelorism from normal fetuses.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 40 条
[1]   Golden ratio: A measure of physical beauty [J].
Abbas S. .
Resonance, 2017, 22 (1) :51-60
[2]  
American College of Radiology, 2019, ACR ACOG AIUM SMFM S
[3]   Fetal Brain MRI Measurements Using a Deep Learning Landmark Network with Reliability Estimation [J].
Avisdris, Netanell ;
Ben Bashat, Dafna ;
Ben-Sira, Liat ;
Joskowicz, Leo .
UNCERTAINTY FOR SAFE UTILIZATION OF MACHINE LEARNING IN MEDICAL IMAGING, AND PERINATAL IMAGING, PLACENTAL AND PRETERM IMAGE ANALYSIS, 2021, 12959 :210-220
[4]   Automatic linear measurements of the fetal brain on MRI with deep neural networks [J].
Avisdris, Netanell ;
Yehuda, Bossmat ;
Ben-Zvi, Ori ;
Link-Sourani, Daphna ;
Ben-Sira, Liat ;
Miller, Elka ;
Zharkov, Elena ;
Ben Bashat, Dafna ;
Joskowicz, Leo .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (09) :1481-1492
[5]   Analysis of errors made on in utero MR studies of the foetal brain in the MERIDIAN study [J].
Batty, Ruth ;
Gawne-Cain, Mary L. ;
Mooney, Cara ;
Mandefield, Laura ;
Bradburn, Michael ;
Mason, Gerald ;
Griffiths, Paul D. .
EUROPEAN RADIOLOGY, 2019, 29 (01) :195-201
[6]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[9]   Diagnostic Imaging of Fetal and Pediatric Orbital Abnormalities [J].
Burns, Natalie S. ;
Iyer, Ramesh S. ;
Robinson, Ashley J. ;
Chapman, Teresa .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) :W797-W808
[10]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)