Development of a new plasma rich in growth factors membrane with improved optical properties

被引:4
作者
Anitua, Eduardo [1 ,2 ,4 ]
Muruzabal, Francisco [1 ,2 ]
de la Fuente, Maria [1 ,2 ]
Merayo-Lloves, Jesus [3 ]
Alkhraisat, Mohammad H. [1 ,2 ]
机构
[1] Biotechnol Inst BTI, Regenerat Med Lab, Vitoria, Spain
[2] UPV EHU Fdn Eduardo Anitua, Univ Inst Regenerat Med & Oral Implantol UIRMI, Res & Dev Dept, Vitoria 01007, Spain
[3] Univ Oviedo, Fdn Invest Oftalmol, Inst Oftalmol Fernandez Vega, Oviedo, Spain
[4] Inst Eduardo Anitua, C Jose Maria Cagigal 19, Vitoria 01005, Spain
关键词
Plasma rich in growth factors; Platelet rich plasma; PRP; Fibrin membrane; Ocular surface diseases; Optical characteristics; AMNIOTIC MEMBRANE; AUTOLOGOUS SERUM; FIBRIN; OPHTHALMOLOGY; TISSUE; CELLS; EYE; TRANSPLANTATION; TRANSPARENCY; DROPS;
D O I
10.1016/j.aanat.2023.152071
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Purpose: The aim of the present work was to develop a fibrin membrane using plasma rich in growth factors (PRGF) technology with improved optical properties to be used for the treatment of ocular surface diseases. Basic procedures: Blood was drawn from three healthy donors, and the volume of PRGF obtained from each donor was divided into two main groups: i) PRGF or ii) platelet-poor plasma (PPP). Each membrane was then used pure or diluted to 90 %, 80 %, 70 %, 60 % and 50 %. The transparency of each of the different membranes was evaluated. The degradation and morphological characterization of each membrane was also performed. Finally, a stability study of the different fibrin membranes was performed.Main findings: The transmittance test showed that the fibrin membrane with the best optical characteristics was obtained after removal of platelets and dilution of fibrin to 50 % (50 % PPP). No significant differences (p > 0.05) were observed between the different membranes in the fibrin degradation test. The stability test showed that the membrane at 50 % PPP retains its optical and physical characteristics after storage at - 20 degrees C for 1 month compared to storage at 4 degrees C. Principalconclusions: The present study describes the development and characterization of a new fibrin membrane with improved optical characteristics while maintaining mechanical and biological character-istics. The physical and mechanical properties of the newly developed membrane are preserved after sto-rage for at least 1 month at - 20 degrees C.(c) 2023 Published by Elsevier GmbH.
引用
收藏
页数:9
相关论文
共 42 条
[1]   Treatment with platelet-rich plasma of surgically related dormant corneal ulcers [J].
Alio, Jorge L. ;
Rodriguez, Alejandra E. ;
De Arriba, Pablo ;
Gisbert, Sandra ;
Abdelghany, Ahmed A. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (05) :515-520
[2]   Progress in the use of plasma rich in growth factors in ophthalmology: from ocular surface to ocular fundus [J].
Anitua, E. ;
De la Sen-Corcuera, B. ;
Orive, G. ;
Sanchez-Avila, R. M. ;
Heredia, P. ;
Muruzabal, F. ;
Merayo-Lloves, J. .
EXPERT OPINION ON BIOLOGICAL THERAPY, 2022, 22 (01) :31-45
[3]  
Anitua E, 1999, INT J ORAL MAX IMPL, V14, P529
[4]   Proteomic Characterization of Plasma Rich in Growth Factors and Undiluted Autologous Serum [J].
Anitua, Eduardo ;
Muruzabal, Francisco ;
Pino, Ander ;
Prado, Roberto ;
Azkargorta, Mikel ;
Elortza, Felix ;
Merayo-Lloves, Jesus .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (22)
[5]   The inclusion of leukocytes into platelet rich plasma reduces scaffold stability and hinders extracellular matrix remodelling. [J].
Anitua, Eduardo ;
Zalduendo, Mar ;
Troya, Maria ;
Tierno, Roberto ;
Alkhraisat, Mohammad H. .
ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2022, 240
[6]   Platelet rich plasma in oral and maxillofacial surgery from the perspective of composition [J].
Anitua, Eduardo ;
Fernandez-de-Retana, Sofia ;
Alkhraisat, Mohammad H. .
PLATELETS, 2021, 32 (02) :174-182
[7]   Implementation of a more physiological plasma rich in growth factor (PRGF) protocol: Anticoagulant removal and reduction in activator concentration [J].
Anitua, Eduardo ;
Prado, Roberto ;
Troya, Maria ;
Zalduendo, Mar ;
de la Fuente, Maria ;
Pino, Ander ;
Muruzabal, Francisco ;
Orive, Gorka .
PLATELETS, 2016, 27 (05) :459-466
[8]   Autologous serum and plasma rich in growth factors in ophthalmology: preclinical and clinical studies [J].
Anitua, Eduardo ;
Muruzabal, Francisco ;
Tayebba, Ali ;
Riestra, Ana ;
Perez, Victor L. ;
Merayo-Lloves, Jesus ;
Orive, Gorka .
ACTA OPHTHALMOLOGICA, 2015, 93 (08) :E605-E614
[9]   A biodegradable fibrin scaffold for mesenchymal stem cell transplantation [J].
Bensaïd, W ;
Triffitt, JT ;
Blanchat, C ;
Oudina, K ;
Sedel, L ;
Petite, H .
BIOMATERIALS, 2003, 24 (14) :2497-2502
[10]   Influence of fibrin network conformation and fibrin fiber diameter on fibrinolysis speed - Dynamic and structural approaches by confocal microscopy [J].
Collet, JP ;
Park, D ;
Lesty, C ;
Soria, J ;
Soria, C ;
Montalescot, G ;
Weisel, JW .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2000, 20 (05) :1354-1361