Arthroscopic-assisted robotic bi-unicompartmental knee arthroplasty: a pilot cadaveric study

被引:0
作者
Fernandez, Andrea [1 ]
Sappey-Marinier, Elliot [2 ]
Lavoie, Frederic [3 ]
Batailler, Cecile [2 ]
Servien, Elvire [2 ,4 ]
Lustig, Sebastien [2 ,5 ]
机构
[1] Nancy Univ Hosp, Emile Galle Surg Ctr, Nancy, France
[2] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[3] Ctr Hosp Univ Montreal CHUM, Orthoped Surg Dept, Montreal, PQ, Canada
[4] Claude Bernard Lyon 1 Univ, Interuniv Lab Biol Mobil, LIBM, EA 7424, Lyon, France
[5] Claude Bernard Lyon 1 Univ, Univ Lyon, LBMC UMR T9406, IFSTTAR, F-69622 Lyon, France
关键词
UKA; Robotics; Arthroscopy; Knee arthroplasty; Mini-invasive surgery; ARTERIAL; ANATOMY; OSTEOARTHRITIS; REPLACEMENT; ALIGNMENT;
D O I
10.1007/s00402-022-04647-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Although bicondylar arthroplasty showed great functional results, it encounters some difficulties to be performed routinely. On the other hand, arthroscopic techniques tend to replace open surgical techniques in sports medicine but strive to be developed in the field of arthroplasty. This study aimed to assess the feasibility of a micro-invasive bi-compartmental knee arthroplasty using both arthroscopic and robotic technologies (A-BiUKA). Materials and Methods The study was conducted on complete fresh-frozen and embalmed cadaveric specimens. The main criterion of judgment was the successful positioning of trial implants through a minimal quad-sparing approach. Arthroscopy was used for bone-morphing and burring, supported by an image-free robotic system. Secondary criteria of judgment were axial deviation (measured using the navigation system), operating time, and incision length. Results Ten A-BiUKA were performed. Implantation was successful in all cases. The mean preoperative frontal deviation was 179.8 degrees +/- 3.2 [175: 185], the mean postoperative frontal deviation was 178.5 degrees +/- 2.2 [175: 182], without any outliers. The mean correction was 1.7 degrees +/- 1.6 [0: 5]. Once the eight first A-UKA were performed, constituting the learning curve, the mean operative time for the remaining twelves surgeries was 90 min +/- 6. The mean skin incision length was 3.35 cm +/- 0.13 [3: 4]. Conclusion Associated arthroscopic and robotic technologies allows to perform Bi-UKA procedure using a quad sparing mini-invasive approach. Clinical prospective studies have to confirm the feasibility and the clinical outcomes of this surgery.
引用
收藏
页码:3439 / 3446
页数:8
相关论文
共 45 条
[1]   Robotic-assisted knee arthroplasty [J].
Banerjee, Samik ;
Cherian, Jeffrey J. ;
Elmallah, Randa K. ;
Jauregui, Julio J. ;
Pierce, Todd P. ;
Mont, Michael A. .
EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (06) :727-735
[2]   Robotic arm-assisted bi-unicompartmental knee arthroplasty maintains natural knee joint anatomy compared with total knee arthroplasty: a prospective randomized controlled trial [J].
Banger, M. S. ;
Johnston, W. D. ;
Razii, N. ;
Doonan, J. ;
Rowe, P. J. ;
Jones, B. G. ;
MacLean, A. D. ;
Blyth, M. J. G. .
BONE & JOINT JOURNAL, 2020, 102B (11) :1511-1518
[3]   Mechanical Forces in Cutaneous Wound Healing: Emerging Therapies to Minimize Scar Formation [J].
Barnes, Leandra A. ;
Marshall, Clement D. ;
Leavitt, Tripp ;
Hu, Michael S. ;
Moore, Alessandra L. ;
Gonzalez, Jennifer G. ;
Longaker, Michael T. ;
Gurtner, Geoffrey C. .
ADVANCES IN WOUND CARE, 2018, 7 (02) :47-56
[4]   MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review [J].
Batailler, Cecile ;
Fernandez, Andrea ;
Swan, John ;
Servien, Elvire ;
Haddad, Fares S. ;
Catani, Fabio ;
Lustig, Sebastien .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (11) :3585-3598
[5]   Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty [J].
Batailler, Cecile ;
White, Nathan ;
Ranaldi, Filippo Maria ;
Neyret, Philippe ;
Servien, Elvire ;
Lustig, Sebastien .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) :1232-1240
[6]   No difference in joint awareness after TKA: a matched-pair analysis of a classic implant and its evolutional design [J].
Behrend, Henrik ;
Zdravkovic, Vilijam ;
Bosch, Marco ;
Hochreiter, Bettina .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (07) :2124-2129
[7]   The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus [J].
Bellemans, Johan ;
Colyn, William ;
Vandenneucker, Hilde ;
Victor, Jan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :45-53
[8]   Custom total knee arthroplasty facilitates restoration of constitutional coronal alignment [J].
Bonnin, Michel P. ;
Beckers, Lucas ;
Leon, Augustin ;
Chauveau, Jules ;
Mueller, Jacobus H. ;
Tibesku, Carsten O. ;
Ait-Si-Selmi, Tarik .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) :464-475
[9]   Faster return to sport after robotic-assisted lateral unicompartmental knee arthroplasty: a comparative study [J].
Canetti, R. ;
Batailler, C. ;
Bankhead, C. ;
Neyret, P. ;
Servien, E. ;
Lustig, S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (12) :1765-1771