During the 16th and 17th centuries, Latin American cities adopted earthen construction techniques from European colonizers. As a result, rammed earth (RE) buildings now occupy an important place in Latin America's cultural heritage. However, earthquakes around the world have shown that unreinforced earthen constructions are highly vulnerable. For several years, researchers in northern South America have been proposing a technique that consists of installing confining steel plates (or wooden elements) on both sides of the RE walls to form a grid. This system has shown excellent performance in controlling seismic damage and increasing strength and ductility capacity. Although researchers have tested full-scale one- and two-story earthen walls under pseudo-static loading in the laboratory, and one- and two-story earthen walls at 1:1 and 1:2 scales on uniaxial and biaxial shaking tables, the behavior of a complete reinforced module (one- or two-story) on a shaking table has never been assessed. The present study presents the results of shaking table tests performed on two-story RE modules at 1:4 scale. The experimental data indicate that the retrofit system with confining steel plates was effective in reducing the seismic damage of earthen constructions. In addition, the comparison of the results of the 1:4 scale tests with the 1:2 and 1:1 scale tests previously conducted by the researchers shows that the acceleration levels of the equivalent prototypes are in the same order of magnitude for the three scales.
引用
收藏
页数:18
相关论文
共 38 条
[1]  
[Anonymous], 2012, Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard f fort (12 400 ft-lbf/ft3 (600 kN-m/m3))
[2]  
[Anonymous], 2017, Norma AIS-610-EP-2017
[3]  
[Anonymous], 2007, SAFETY PRECAUTIONS M, P1
[4]  
[Anonymous], 2017, A37017 ASTM
[5]  
ASTM, 2017, STANDARD TEST METHOD, DOI [10.1520/C0109_C0109M-21, DOI 10.1520/D4318-17E01]
[6]   Characterization of the mechanical and physical properties of unstabilized rammed earth: A review [J].
Avila, Fernando ;
Puertas, Esther ;
Gallego, Rafael .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 270
[7]  
Blondet M., 2011, EERI IAEE WORLD HOUS, V56, P13, DOI [DOI 10.1227/01.NEU.0000255422.86054.51, 10.1227/01.NEU.0000255422.86054.51]
[8]  
Blondet M., 2006, Conf. Earthq. Eng, V2006, P4223
[9]   Seismic Behavior and Shaking Direction Influence on Adobe Wall Structures Reinforced with Geogrid [J].
Bossio, Stefano ;
Blondet, Marcia ;
Rihal, Satwant .
EARTHQUAKE SPECTRA, 2013, 29 (01) :59-84
[10]   In-plane shear behaviour of adobe masonry wallets strengthened with textile reinforced mortar [J].
Cassese, Paolino ;
Balestrieri, Claudio ;
Fenu, Luigi ;
Asprone, Domenico ;
Parisi, Fulvio .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 306