Hypoperfusion context as a predictor of 28-d all-cause mortality in septic shock patients: A comparative observational study

被引:2
作者
Kataria, Sahil [1 ]
Singh, Omender [1 ]
Juneja, Deven [1 ]
Goel, Amit [1 ]
Bhide, Madhura [1 ]
Yadav, Devraj [1 ]
机构
[1] Max Super Special Hosp, Inst Crit Care Med, 1 Press Enclave Rd, New Delhi 110017, India
关键词
Capillary refill time; Central venous saturation; Hypoperfusion; Lactate; Mortality; PCO2; gap; Septic shock; VENOUS OXYGEN-SATURATION; CAPILLARY REFILL TIME; SEPSIS; RESUSCITATION; THERAPY; TRENDS;
D O I
10.12998/wjcc.v11.i16.3765
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND As per the latest Surviving Sepsis Campaign guidelines, fluid resuscitation should be guided by repeated measurements of blood lactate levels until normalization. Nevertheless, raised lactate levels should be interpreted in the clinical context, as there may be other causes of elevated lactate levels. Thus, it may not be the best tool for real-time assessment of the effect of hemodynamic resuscitation, and exploring alternative resuscitation targets should be an essential research priority in sepsis. AIM To compare the 28-d mortality in two clinical patterns of septic shock: hyperlactatemic patients with hypoperfusion context and hyperlactatemic patients without hypoperfusion context. METHODS This prospective comparative observational study carried out on 135 adult patients with septic shock that met Sepsis-3 definitions compared patients with hyperlactatemia in a hypoperfusion context (Group 1, n = 95) and patients with hyperlactatemia in a non-hypoperfusion context (Group 2, n = 40). Hypoperfusion context was defined by a central venous saturation less than 70%, central venous-arterial PCO2 gradient [P(cv-a)CO2] >= 6 mmHg, and capillary refilling time (CRT) >= 4 s. The patients were observed for various macro and micro hemodynamic parameters at regular intervals of 0 h, 3 h, and 6 h. All-cause 28-d mortality and all other secondary objective parameters were observed at specified intervals. Nominal categorical data were compared using the chi(2) or Fisher's exact test. Non-normally distributed continuous variables were compared using the Mann-Whitney U test. Receiver operating characteristic curve analysis with the Youden index determined the cutoff values of lactate, CRT, and metabolic perfusion parameters to predict the 28-d all-cause mortality. A P value of < 0.05 was considered significant. RESULTS Patient demographics, comorbidities, baseline laboratory, vital parameters, source of infection, baseline lactate levels, and lactate clearance at 3 h and 6 h, Sequential Organ Failure scores, need for invasive mechanical ventilation, days on mechanical ventilation, and renal replacement therapy-free days within 28 d, duration of intensive care unit stay, and hospital stay were comparable between the two groups. The stratification of patients into hypoperfusion and non-hypoperfusion context did not result in a significantly different 28-d mortality (24% vs 15%, respectively; P = 0.234). However, the patients within the hypoperfusion context with high P(cv-a)CO2 and CRT (P = 0.022) at baseline had significantly higher mortality than Group 2. The norepinephrine dose was higher in Group 1 but did not achieve statistical significance with a P > 0.05 at all measured intervals. Group 1 had a higher proportion of patients requiring vasopressin and the mean vasopressor-free days out of the total 28 d were lower in patients with hypoperfusion (18.88 +/- 9.04 vs 21.08 +/- 8.76; P = 0.011). The mean lactate levels and lactate clearance at 3 h and 6 h, CRT, P(cv-a)CO2 at 0 h, 3 h, and 6 h were found to be associated with 28-d mortality in patients with septic shock, with lactate levels at 6 h having the best predictive value (area under the curve lactate at 6 h: 0.845). CONCLUSION Septic shock patients fulfilling the hypoperfusion and non-hypoperfusion context exhibited similar 28-d all-cause hospital mortality, although patients with hypoperfusion displayed a more severe circulatory dysfunction.
引用
收藏
页数:16
相关论文
共 34 条
[1]   A hypoperfusion context may aid to interpret hyperlactatemia in sepsis-3 septic shock patients: a proof-of-concept study [J].
Alegria, Leyla ;
Vera, Magdalena ;
Dreyse, Jorge ;
Castro, Ricardo ;
Carpio, David ;
Henriquez, Carolina ;
Gajardo, Daniela ;
Bravo, Sebastian ;
Araneda, Felipe ;
Kattan, Eduardo ;
Torres, Pedro ;
Ospina-Tascon, Gustavo ;
Teboul, Jean-Louis ;
Bakker, Jan ;
Hernandez, Glenn .
ANNALS OF INTENSIVE CARE, 2017, 7
[2]   Impact of patient and environmental factors on capillary refill time in adults [J].
Anderson, Bronwyn ;
Kelly, Anne-Maree ;
Kerr, Debra ;
Clooney, Megan ;
Jolley, Damien .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (01) :62-65
[3]   Prevalence of low central venous oxygen saturation in the first hours of intensive care unit admission and associated mortality in septic shock patients: a prospective multicentre study [J].
Boulain, Thierry ;
Garot, Denis ;
Vignon, Philippe ;
Lascarrou, Jean-Baptiste ;
Desachy, Arnaud ;
Botoc, Vlad ;
Follin, Arnaud ;
Frat, Jean-Pierre ;
Bellec, Frederic ;
Quenot, Jean-Pierre ;
Mathonnet, Armelle ;
Dequin, Pierre-Francois .
CRITICAL CARE, 2014, 18 (06)
[4]   Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality [J].
Boyd, John H. ;
Forbes, Jason ;
Nakada, Taka-aki ;
Walley, Keith R. ;
Russell, James A. .
CRITICAL CARE MEDICINE, 2011, 39 (02) :259-265
[5]   ADVERSE LIGHTING CONDITION EFFECTS ON THE ASSESSMENT OF CAPILLARY REFILL [J].
BROWN, LH ;
PRASAD, NH ;
WHITLEY, TW .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1994, 12 (01) :46-47
[6]   Effects of capillary refill time-vs. lactate-targeted fluid resuscitation on regional, microcirculatory and hypoxia-related perfusion parameters in septic shock: a randomized controlled trial [J].
Castro, Ricardo ;
Kattan, Eduardo ;
Ferri, Giorgio ;
Pairumani, Ronald ;
Daniel Valenzuela, Emilio ;
Alegria, Leyla ;
Oviedo, Vanessa ;
Pavez, Nicolas ;
Soto, Dagoberto ;
Vera, Magdalena ;
Santis, Cesar ;
Astudillo, Brusela ;
Cid, Maria Alicia ;
Bravo, Sebastian ;
Ospina-Tascon, Gustavo ;
Bakker, Jan ;
Hernandez, Glenn .
ANNALS OF INTENSIVE CARE, 2020, 10 (01)
[7]  
de Souza RP, 2021, Arxiv, DOI arXiv:2102.13611
[8]  
Dellinger RP, 2013, INTENS CARE MED, V39, P165, DOI [10.1007/s00134-012-2769-8, 10.1097/CCM.0b013e31827e83af]
[9]   Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions [J].
Dueck, MH ;
Klimek, M ;
Appenrodt, S ;
Weigand, C ;
Boerner, U .
ANESTHESIOLOGY, 2005, 103 (02) :249-257
[10]  
Evans L, 2021, INTENS CARE MED, V47, P1181, DOI [10.1097/CCM.0000000000005337, 10.1007/s00134-021-06506-y]