Comparison of the TEMPO binocular perimeter and Humphrey field analyzer

被引:2
作者
Nishida, Takashi [1 ,2 ]
Weinreb, Robert N. [1 ,2 ]
Arias, Juan [1 ,2 ]
Vasile, Cristiana [1 ,2 ]
Moghimi, Sasan [1 ,2 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, 9500 Campus Point Dr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Viterbi Family Dept Ophthalmol, 9500 Campus Point Dr, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
VISUAL-FIELD; RELIABILITY;
D O I
10.1038/s41598-023-48105-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study compared between TEMPO, a new binocular perimeter, with the Humphrey Field Analyzer (HFA). Patients were tested with both TEMPO 24-2 Ambient Interactive Zippy Estimated by Sequential Testing (AIZE)-Rapid and HFA 24-2 Swedish Interactive Threshold Algorithm (SITA)-Fast in a randomized sequence on the same day. Using a mixed-effects model, visual field (VF) parameters and reliability indices were compared. Retinal nerve fiber layer (RNFL) thickness was measured using Cirrus optical coherence tomography (OCT), and coefficient of determinations for VF and OCT parameters were calculated and compared using Akaike information criteria. 740 eyes (including 68 healthy, 262 glaucoma suspects, and 410 glaucoma) of 370 participants were evaluated. No significant differences were seen in mean deviation and visual field index between the two perimeters (P > 0.05). A stronger association between VF mean sensitivity (dB or 1/L) and circumpapillary RNFL was found for TEMPO (adjusted R-2 = 0.25; Akaike information criteria [AIC] = 5235.5 for dB, and adjusted R-2 = 0.29; AIC = 5200.8 for 1/L, respectively) compared to HFA (adjusted R-2 = 0.22; AIC = 5263.9 for dB, and adjusted R-2 = 0.22; AIC = 5262.7 for 1/L, respectively). Measurement time was faster for TEMPO compared to HFA (261 s vs. 429 s, P < 0.001). Further investigations are needed to assess the long-term monitoring potential of this binocular VF test.
引用
收藏
页数:8
相关论文
共 50 条
[31]   A pupil perimeter for objective visual field measurement [J].
Maeda, Fumiatsu ;
Tanzawa, Keiichi ;
Fukushima, Shogo ;
Inakagata, Satoru ;
Kani, Kazutaka ;
Tabuchi, Akio .
2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, :1116-+
[32]   Measurement of paracentral stereopsis using a new method with the binocular open perimeter imovifa® in normal adults [J].
Wakayama, Akemi ;
Matsumoto, Chota ;
Utamura, Keisuke ;
Narita, Ryo ;
Kusaka, Shunji .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2024, 68 (04) :355-361
[33]   Comparison of refractive value and pupil size under monocular and binocular conditions between the Spot Vision Screener and binocular open-field autorefractor [J].
Satou, Tsukasa ;
Takahashi, Yoshiaki ;
Niida, Takahiro .
STRABISMUS, 2020, 28 (04) :186-193
[34]   Comparison of Compass and Humphrey perimeters in detecting glaucomatous defects [J].
Fogagnolo, Paolo ;
Modarelli, Antonio ;
Oddone, Francesco ;
Digiuni, Maurizio ;
Montesano, Giovanni ;
Orzalesi, Nicola ;
Rossetti, Luca .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) :598-606
[35]   Predicting the Extent of Damage in the Humphrey Field Analyzer 24-2 Visual Fields Using 10-2 Test Results in Patients With Advanced Glaucoma [J].
Asaoka, Ryo ;
Sugisaki, Kenji ;
Inoue, Toshihiro ;
Yoshikawa, Keiji ;
Kanamori, Akiyasu ;
Yamazaki, Yoshio ;
Ishikawa, Shinichiro ;
Uchida, Kenichi ;
Iwase, Aiko ;
Araie, Makoto .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (02)
[36]   Comparison of Humphrey MATRIX and Swedish interactive threshold algorithm standard strategy in detecting early glaucomatous visual field loss [J].
Prema, Raju ;
Ronnie, George ;
Hemamalini, Arvind ;
Ve, Ramesh Sathyamangalam ;
Baskaran, Mani ;
Vijaya, Lingam .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2009, 57 (03) :207-211
[37]   Acute effects of sildenafil on Humphrey visual field and intraocular pressure [J].
Ermis S.S. ;
Inan U.U. ;
Samli M. ;
Ozturk F. .
International Ophthalmology, 2004, 25 (2) :69-72
[38]   MAIA and Humphrey Perimetry Differ in Their Estimation of Homonymous Visual Field Defects [J].
Redmond, Bryan V. ;
Fahrenthold, Berkeley K. ;
Yang, Jingyi ;
Saionz, Elizabeth L. ;
Cavanaugh, Matthew R. ;
Huxlin, Krystel R. .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (11)
[39]   The efficacy of the Dicon screening field to detect eyes with glaucomatous field loss by Humphrey threshold testing [J].
Huang, AS ;
Smith, TD ;
Quigley, HA .
JOURNAL OF GLAUCOMA, 1998, 7 (03) :158-164
[40]   Properties of receptive field on binocular fusion stimulation in the central visual field [J].
Akemi Wakayama ;
Chota Matsumoto ;
Kazuyo Ohmure ;
Fumiko Matsumoto ;
Yoshikazu Shimomura .
Graefe’s Archive for Clinical and Experimental Ophthalmology, 2002, 240 :743-747