Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis

被引:1
作者
Prukngampun, Natthida [1 ]
Densupsoontorn, Narumon [2 ]
Pattaragarn, Anirut [1 ]
Pooliam, Julaporn [3 ]
Tinnabut, Intraparch [4 ]
Sumboonnanonda, Achra [1 ]
Supavekin, Suroj [1 ]
Piyaphanee, Nuntawan [1 ]
Lomjansook, Kraisoon [1 ]
Thunsiribuddhichai, Yarnarin [1 ]
Chaiyapak, Thanaporn [1 ]
机构
[1] Mahidol Univ, Fac Med, Dept Pediat, Div Nephrol,Siriraj Hosp, Bangkok, Thailand
[2] Mahidol Univ, Fac Med, Dept Pediat, Div Nutr,Siriraj Hosp, Bangkok, Thailand
[3] Mahidol Univ, Fac Med, Res Dept, Res Dev Div,Siriraj Hosp, Bangkok, Thailand
[4] Mahidol Univ, Fac Med, Dept Nursing, Div Pediat Nursing,Siriraj Hosp, Bangkok, Thailand
关键词
Peritoneal dialysis; Bioelectrical impedance analysis; Body composition; Pediatrics; HYDRATION STATUS; FLUID STATUS; BIOIMPEDANCE; BODY; GUIDELINE; CHILDREN;
D O I
10.1007/s00467-023-06219-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundPrevious adult studies have yielded conflicting results regarding whether the presence (D +) or absence (D-) of peritoneal dialysate affects the accuracy of bioelectrical impedance analysis (BIA) measurements. The aim of this study was to investigate whether the accuracy of BIA data varies between D + and D- measurements in children.MethodsThis cross-sectional study recruited chronic kidney disease stage 5 patients aged 3 to 18 years who received peritoneal dialysis. Body composition was assessed by multifrequency BIA, and values were compared between D + and D- measurements using the intraclass correlation coefficient (ICC).ResultsFifty paired BIA measurements were collected from 18 patients with a mean age of 13.6 +/- 4.1 years and a mean dialysate fill volume of 1,006 +/- 239.7 ml/m2. Sixteen out of 17 BIA parameters (94.1%) exhibited excellent correlations between D + and D- measurements (ICC values = 0.954, 0.998). There was a trend of increased fluid status, including extracellular water, edema index, and overhydration, in D + measurements, with mean differences (95% CIs) of 0.5 (0.4, 0.6) L, 0.002 (0.001, 0.002), and 0.1 (0.1, 0.2) L, respectively. Soft lean mass and fat-free mass were higher in D + measurements, with mean differences (95% CIs) of 1.4 (1.2, 1.6), and 1.6 (1.4, 1.8) kg, respectively. In addition, patients older than 10 years had a stronger correlation between D + and D- measurements than younger patients.ConclusionsA total of 94.1% of BIA parameters exhibited excellent correlations between D + and D- measurements, especially patients older than 10 years. We recommend that BIA measurements be collected from children regardless of the presence of peritoneal dialysate.
引用
收藏
页码:1499 / 1507
页数:9
相关论文
共 24 条
[1]   INTRAPERITONEAL FLUID OVERESTIMATES HYDRATION STATUS ASSESSMENT BY BIOIMPEDANCE SPECTROSCOPY [J].
Arroyo, David ;
Panizo, Nayara ;
Abad, Soraya ;
Vega, Almudena ;
Rincon, Abraham ;
Perez de Jose, Ana ;
Lopez-Gomez, Juan M. .
PERITONEAL DIALYSIS INTERNATIONAL, 2015, 35 (01) :85-89
[2]  
Bureau of Nutrition Department of Public Health Thailand Ministry of Public Health, 2021, National growth reference for children 5-19 years
[3]  
Cheng C H, 2000, Zhonghua Yi Xue Za Zhi (Taipei), V63, P758
[4]   Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients? [J].
Davenport, A. .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (02) :223-225
[5]  
Fischbach M, 2000, PERITON DIALYSIS INT, V20, P603
[6]  
Haapio M, 2012, CONTRIB NEPHROL, V178, P238, DOI 10.1159/000337885
[7]   Epidemiology of pediatric chronic kidney disease/kidney failure: learning from registries and cohort studies [J].
Harada, Ryoko ;
Hamasaki, Yuko ;
Okuda, Yusuke ;
Hamada, Riku ;
Ishikura, Kenji .
PEDIATRIC NEPHROLOGY, 2022, 37 (06) :1215-1229
[8]   Assessment and management of fluid overload in children on dialysis [J].
Hayes, Wesley ;
Paglialonga, Fabio .
PEDIATRIC NEPHROLOGY, 2019, 34 (02) :233-242
[9]  
Ikizler TA, 2020, AM J KIDNEY DIS, V76, pS11
[10]  
Inbody Co Ltd, 2015, Inbody user's manual