Wind Turbine Active Fault Tolerant Control Based on Backstepping Active Disturbance Rejection Control and a Neurofuzzy Detector

被引:0
|
作者
Assia, Hamza [1 ]
Boulouiha, Houari Merabet [1 ]
Chicaiza, William David [2 ]
Escano, Juan Manuel [2 ]
Kacimi, Abderrahmane [3 ]
Martinez-Ramos, Jose Luis [4 ]
Denai, Mouloud [5 ]
机构
[1] Natl Polytech Sch Oran Maurice Audin, Dept Elect Engn, Lab Automation & Syst Anal LAAS, Oran 31000, Algeria
[2] Univ Seville, Dept Syst Engn & Automatic Control, Seville 41092, Spain
[3] Inst Maintenance & Ind Safety, Dept Instrumentat Maintenance, Oran 31000, Algeria
[4] Univ Seville, Dept Elect Engn, Seville 41092, Spain
[5] Univ Hertfordshire, Dept Engn & Technol, Hatfield AL10 9AB, England
基金
欧盟地平线“2020”;
关键词
active fault-tolerant control; backstepping; active disturbance rejection control; adaptive neurofuzzy inference system; principal component analysis; TRACKING;
D O I
10.3390/en16145455
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind energy conversion systems have become an important part of renewable energy history due to their accessibility and cost-effectiveness. Offshore wind farms are seen as the future of wind energy, but they can be very expensive to maintain if faults occur. To achieve a reliable and consistent performance, modern wind turbines require advanced fault detection and diagnosis methods. The current research introduces a proposed active fault-tolerant control (AFTC) system that uses backstepping active disturbance rejection theory (BADRC) and an adaptive neurofuzzy system (ANFIS) detector in combination with principal component analysis (PCA) to compensate for system disturbances and maintain performance even when a generator actuator fault occurs. The simulation outcomes demonstrate that the suggested method successfully addresses the actuator generator torque failure problem by isolating the faulty actuator, providing a reliable and robust solution to prevent further damage. The neurofuzzy detector demonstrates outstanding performance in detecting false data in torque, achieving a precision of 90.20% for real data and 100% for false data. With a recall of 100%, no false negatives were observed. The overall accuracy of 95.10% highlights the detector's ability to reliably classify data as true or false. These findings underscore the robustness of the detector in detecting false data, ensuring the accuracy and reliability of the application presented. Overall, the study concludes that BADRC and ANFIS detection and isolation can improve the reliability of offshore wind farms and address the issue of actuator generator torque failure.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Fault-Tolerant Control of D-PMSG Demagnetization Based on Linear Active Disturbance Rejection Controller
    Luo, Bing
    Liu, Bozhong
    Peng, Sicheng
    Yu, Zhi
    Zhang, Yang
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2024, 123 : 119 - 126
  • [42] Research of wind turbine virtual inertia first-order active disturbance rejection control
    Wang, Yi
    Jiang, Hanhong
    Xing, Pengxiang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (04): : 153 - 163
  • [43] An Active Disturbance Rejection Control of Large Wind Turbine Pitch Angle Based on Extremum-Seeking Algorithm
    Zou, Yarong
    Tan, Wen
    Jin, Xingkang
    Wang, Zijian
    ENERGIES, 2022, 15 (08)
  • [44] Optimal bandwidth active disturbance rejection control for wind turbine grid-connection based on neural network
    Zhou X.
    Yang Z.
    Ma Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (09): : 226 - 235
  • [45] Fault tolerant control based on active fault diagnosis
    Niemann, H
    ACC: PROCEEDINGS OF THE 2005 AMERICAN CONTROL CONFERENCE, VOLS 1-7, 2005, : 2224 - 2229
  • [46] Fault Tolerant Control of a Quadrotor Unmanned Aerial Vehicle Based on Active Disturbance Rejection Control and Two-Stage Kalman Filter
    Du, Yusheng
    Huang, Peng
    Cheng, Yun
    Fan, Yunlei
    Yuan, Yinlong
    IEEE ACCESS, 2023, 11 : 67556 - 67566
  • [47] Performance Robustness Comparison of Active Disturbance Rejection Control and Adaptive Backstepping Sliding Mode Control
    Kang, Ying
    Li, Donghai
    Lao, Dazhong
    ASIASIM 2012, PT II, 2012, 324 : 275 - +
  • [48] Active Disturbance Rejection Control of Air-Breathing Hypersonic Vehicles Based on Backstepping Method
    Zhang Sai
    Wang Qing
    Dong Chaoyang
    Ran Maopeng
    2015 34TH CHINESE CONTROL CONFERENCE (CCC), 2015, : 866 - 870
  • [49] Active Fault Tolerant Control of a Wind Turbine via T-S Fuzzy Model Predictive Control
    Feng, Xiaoran
    Patton, Ron
    2014 22ND MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2014, : 446 - 451
  • [50] Active Disturbance Rejection Trajectory Tracking Control for Pneumatic Servo System Based on Backstepping Approach
    Yang, Yafei
    Zhao, Ling
    Fan, Xiaozhao
    Liu, Zhixin
    2015 34TH CHINESE CONTROL CONFERENCE (CCC), 2015, : 4308 - 4312