Voltammetric studies and spectroscopic investigations of the interaction of an anticancer drug bevacizumab-DNA and analytical applications of disposable pencil graphite sensor

被引:19
作者
Aslan, Mehmet [1 ]
Aydin, Firat [1 ]
Levent, Abdulkadir [2 ]
机构
[1] Dicle Univ, Fac Sci, Dept Chem, Diyarbakir, Turkiye
[2] Batman Univ, Fac Arts & Sci, Dept Chem, Batman, Turkiye
关键词
Bevacizumab; DNA interaction; PGE; Voltammetric; Spectrometric; DIRECT ELECTROCHEMICAL OXIDATION; MONOCLONAL-ANTIBODY; SOLID ELECTRODES; AMINO-ACIDS; BIOSENSOR; CYSTEINE; TYROSINE; THERAPY; PROTEIN; AFM;
D O I
10.1016/j.talanta.2023.124893
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, simple, fast electrochemical biosensor for the DNA interaction of bevacizumab (BEVA), which is used as a targeted drug in cancer treatment, was developed using the differential pulse voltammetry (DPV) technique with pencil graphite electrode (PGE). In the work, PGE was electrochemically activated in a supporting electrolyte medium of +1.4 V/60 s (PBS pH 3.0). Surface characterization of PGE was carried out by SEM, EDX, EIS, and CV techniques. Determination and electrochemical properties of BEVA were examined with CV and DPV techniques. BEVA gave a distinct analytical signal on the PGE surface at a potential of +0.90 V (vs. Ag/AgCl). In the procedure proposed in this study, BEVA gave a linear response on PGE in PBS (pH 3.0 containing 0.02 M NaCl) (0.1 mg mL-1 - 0.7 mg mL-1) with LOD and LOQ values of 0.026 mg mL-1 and 0.086 & mu;g mL-1, respectively. BEVA was reacted with 20 & mu;g mL-1 DNA in PBS for 150 s and analytical peak signals for adenine and guanine bases were evaluated. The interaction between BEVA-DNA was supported by UV-Vis. Absorption spectrometry and the binding constant was determined as 7.3 x 104.
引用
收藏
页数:8
相关论文
共 50 条
[1]   Synthesis, Speciation, DNA Binding, Electrochemical and Antiproliferative Properties of Pd(II) Complexes Designed to Improve the Interaction with DNA [J].
AL-Gedany, Haneen H. ;
Shoukry, Azza A. ;
Al-Mhayawi, Saedah R. .
EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (07) :3913-3926
[2]   Sustained Release of a Monoclonal Antibody from Electrochemically Prepared Mesoporous Silicon Oxide [J].
Andrew, Jennifer S. ;
Anglin, Emily J. ;
Wu, Elizabeth C. ;
Chen, Michelle Y. ;
Cheng, Lingyun ;
Freeman, William R. ;
Sailor, Michael J. .
ADVANCED FUNCTIONAL MATERIALS, 2010, 20 (23) :4168-4174
[3]   A novel electrochemical DNA biosensor based on poly-(5-amino-2-mercapto-1,3,4-thiadiazole) modified glassy carbon electrode for the determination of nitrofurantoin [J].
Aydogdu, Gozde ;
Gunendi, Gulendem ;
Zeybek, Derya Koyuncu ;
Zeybek, Bulent ;
Pekyardimci, Sule .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 197 :211-219
[4]   Similarity assessment of charge variants for bevacizumab biosimilar formulations using imaged capillary isoelectric focusing [J].
Bana, Arpit ;
Mehta, Priti .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (15-16) :801-808
[5]   Protocol for bevacizumab purification using Ac-PHQGQHIGVSK-agarose [J].
Barredo, Gabriela R. ;
Giudicessi, Silvana L. ;
Martinez Ceron, Maria C. ;
Saavedra, Soledad L. ;
Rodriguez, Santiago ;
Filgueira Risso, Lucas ;
Erra-Balsells, Rosa ;
Mahler, Gustavo ;
Albericio, Fernando ;
Cascone, Osvaldo ;
Camperi, Silvia A. .
METHODSX, 2020, 7
[6]   Sensitive and selective voltammetric determination of anti-cancer agent shikonin on sepiolite clay/TiO2 nanoparticle/MWCNTs composite carbon paste sensor and investigation of its electro-oxidation mechanism [J].
Bayraktepe, Dilek Eskikoy ;
Yazan, Zehra ;
Polat, Kamran .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 :38-45
[7]   In-depth analysis of monoclonal antibodies using microfluidic capillary electrophoresis and native mass spectrometry [J].
Carillo, Sara ;
Jakes, Craig ;
Bones, Jonathan .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
[8]   Development of a general method for quantifying IgG-based therapeutic monoclonal antibodies in human plasma using protein G purification coupled with a two internal standard calibration strategy using LC-MS/MS [J].
Chiu, Huai-Hsuan ;
Liao, Hsiao-Wei ;
Shao, Yu-Yun ;
Lu, Yen-Shen ;
Lin, Ching-Hung ;
Tsai, I-Lin ;
Kuo, Ching-Hua .
ANALYTICA CHIMICA ACTA, 2018, 1019 :93-102
[9]   A Critical Review of Biological Properties, Delivery Systems and Analytical/Bioanalytical Methods for Determination of Bevacizumab [J].
Di Filippo, Leonardo Delello ;
dos Santos, Karen Cristina ;
Hanck-Silva, Gilmar ;
de Lima, Felipe Tita ;
Gremiao, Maria Palmira Daflon ;
Chorilli, Marlus .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 51 (05) :445-453
[10]  
Eksin E, 2013, ELECTROANAL, V25, P2321