Investigating the structural damage in Hatay province after Kahramanmaras,-Türkiye earthquake sequences

被引:49
作者
Altunsu, Elif [1 ,2 ]
Gunes, Onur [1 ]
Ozturk, Sezer [1 ,3 ]
Sorosh, Shokrullah [4 ]
Sari, Ali [1 ]
Beeson, Saadet Toker [5 ]
机构
[1] Istanbul Tech Univ, Dept Civil Engn, Istanbul, Turkiye
[2] Istanbul Univ Cerrahpasa, Dept Civil Engn, Istanbul, Turkiye
[3] Fatih Sultan Mehmet Vakif Univ, Dept Civil Engn, Istanbul, Turkiye
[4] Univ Calif San Diego, Dept Struct Engn, San Diego, CA USA
[5] Univ Texas San Antonio, Klesse Coll Engn & Integrated Design, San Antonio, TX USA
关键词
Structural failure; Seismic effect; Kahramanmaras; earthquakes; Earthquake; Ground motion; TURKEY EARTHQUAKE; AUGUST; 17; CONCRETE; BUILDINGS;
D O I
10.1016/j.engfailanal.2023.107857
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
On February 6, 2023, two heavy earthquakes with moment magnitudes (MW) of 7.7 and 7.6 hit the Kahramanmaras, region in southeast Turkiye. Aftershocks of moment magnitude of 6 occurred consequently. These earthquakes affected more than 14 million people, and caused severe damage to civil infrastructure including buildings, government offices, religious buildings, dams, bridges, airports, and roads. After the earthquakes, a group of researchers visited the Hatay province to assess the response of buildings. Hatay was one of the most heavily affected cities in the region. The researchers gathered data on damaged reinforced concrete buildings, steel structures, as well as masonry buildings. This paper focuses on discussing the findings and analyzing the gathered data from reinforced concrete buildings and steel structures. A wide variety of issues that resulted in heavy damage or, in some cases, complete collapse of the buildings are discussed. These problems include construction mistakes such as insufficient shear reinforcements, neglected corrosion, utilizing low-quality concrete, insufficient development length in flexural reinforcements, and strong beam- weak column failure. In addition, various design errors including excessive torsional response of buildings, rigidity difference in two orthogonal directions of east-west and north-south of the building plan, pounding effect, short column failure, and development of weak and soft stories are described using gathered pictorial data. Finally, recommendations were made, and conclusions were drawn based on previous experimental and numerical studies of the seismic behavior of buildings as well as Turkish Building Earthquake Code (TBEC- 2018) requirements.
引用
收藏
页数:25
相关论文
共 52 条
[1]   Structural engineering aspects of the June 27, 1998 Adana-Ceyhan (Turkey) earthquake [J].
Adalier, K ;
Aydingun, O .
ENGINEERING STRUCTURES, 2001, 23 (04) :343-355
[2]  
adas.afad, ABOUT US
[3]  
AFAD, 2023, Pazarcik (Kahramanmaras MW 7.7) and Elbistan (Kahramanmaras MW 7.6) Earthquakes Preliminary Report
[4]  
[Anonymous], 2007, TEC-2007
[5]  
[Anonymous], 1998, TEC-1998,
[6]  
[Anonymous], 2016, 402303 UFC US DEP DE
[7]  
[Anonymous], 1975, TEC-1975
[8]  
[Anonymous], 2018, TBEC-2018, Turkiye Building Earthquake Code
[9]  
[Anonymous], 2010, Minimum Design Loads for Buildings and Other Structures
[10]   What is to be learned from damage and failure of reinforced concrete structures during recent earthquakes in Turkey? [J].
Arslan, M. H. ;
Korkmaz, H. H. .