Randomized Trial of Surfactant Therapy via Laryngeal Mask Airway Versus Brief Tracheal Intubation in Neonates Born Preterm

被引:20
|
作者
Gallup, Jacqueline A. [1 ,2 ]
Ndakor, Sussan Mbi [1 ,3 ]
Pezzano, Chad [1 ,4 ]
Pinheiro, Joaquim M. B. [1 ]
机构
[1] Albany Med Coll, Dept Pediat, Albany, NY USA
[2] Faxton St Lukes Healthcare, Utica, NY USA
[3] UnityPoint Hlth, Waterloo, IA USA
[4] Albany Med Ctr, Cardioresp Serv Dept, Albany, NY USA
关键词
ENDOTRACHEAL INTUBATION; INFANTS; PREMEDICATION; NONINFERIORITY; REMIFENTANIL; RESPONSES; PRESSURE; CATHETER; EFFICACY;
D O I
10.1016/j.jpeds.2022.10.009
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To evaluate the possible noninferiority of surfactant administration via laryngeal mask airway (LMA) vs endotracheal tube (ETT) in avoiding the requirement for mechanical ventilation in preterm neonates with respiratory distress syndrome (RDS). Study design This was a randomized controlled trial including infants born at 27 to 36 weeks of gestation, >800 g, diagnosed with RDS and receiving fraction of inspired oxygen 0.30-0.60 via noninvasive respiratory support. Infants were randomized to surfactant via LMA (with atropine premedication) or ETT (InSuRE approach with atropine and remifentanil premedication). Primary outcome was failure of surfactant treatment to prevent the need for mechanical ventilation. Results Patients were randomized, 51 to LMA and 42 to the ETT group. Both groups had similar baseline characteristics, with birth weights ranging from 810 to 3560 g. Failure rate was 29% in the ETT group and 20% in the LMA group (P =.311). This difference was due to early failures (within 1 hour), with 12.5% in the ETT group and 2% in the LMA group (P =.044). Surfactant therapy via LMA was non-inferior to administration via ETT; failure risk difference -9.0% (CI -infinity to 5.7%). Efficacy in decreasing fraction of inspired oxygen, number of surfactant doses administered, time to wean off all respiratory support, rates of adverse events, and outcomes including pneumothorax and BPD diagnosis did not differ between groups. Conclusions Surfactant therapy via LMA was noninferior to administration via ETT and it decreased early failures, possibly by avoiding adverse effects of premedication, laryngoscopy, and intubation. These characteristics make LMA a desirable conduit for surfactant administration.
引用
收藏
页码:17 / +
页数:10
相关论文
共 27 条
  • [1] Randomized trial of laryngeal mask airway versus endotracheal intubation for surfactant delivery
    Pinheiro, J. M. B.
    Santana-Rivas, Q.
    Pezzano, C.
    JOURNAL OF PERINATOLOGY, 2016, 36 (03) : 196 - 201
  • [2] A randomized controlled trial of the laryngeal mask airway for surfactant administration in neonates
    Barbosa, Rosilu F.
    Simoes e Silva, Ana C.
    Silva, Yerkes P.
    JORNAL DE PEDIATRIA, 2017, 93 (04) : 343 - 350
  • [3] Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial
    Seet, Edwin
    Rajeev, Subramanyam
    Firoz, Tamal
    Yousaf, Farhanah
    Wong, Jean
    Wong, David T.
    Chung, Frances
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 602 - 607
  • [4] Randomized Clinical Trial Comparing the Success Rate of Blockbuster Intubating Laryngeal Mask Airway Versus Fastrach Intubating Laryngeal Mask Airway During Blind Endotracheal Intubation
    Yuvaraj, V
    Pratibha, S. D.
    Alalamath, Santosh
    Karigar, Shivanand L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [5] Laryngeal Mask Airway for Surfactant Administration Versus Standard Treatment Methods in Preterm Neonates with Respiratory Distress Syndrome: A Systematic Review and Meta- analysis
    Al Ali, Roqaia Ayesh
    Gautam, Bishal
    Miller, Michael R.
    Coulson, Sherry
    Yuen, Doris
    AMERICAN JOURNAL OF PERINATOLOGY, 2022, 39 (13) : 1433 - 1440
  • [6] Laryngeal Mask Airway for Surfactant Administration Versus Standard Treatment Methods in Preterm Neonates with Respiratory Distress Syndrome: A Systematic Review and Meta-Analysis
    Al Ali, Roqaia Ayesh
    Gautam, Bishal
    Miller, Michael R.
    Coulson, Sherry
    Yuen, Doris
    AMERICAN JOURNAL OF PERINATOLOGY, 2021,
  • [7] Laryngeal Mask Airway Versus Tracheal Intubation for Laparoscopic Hernia Repair in Children: Analysis of Respiratory Complications
    Nevescanin, Ana
    Vickov, Josip
    Baloevic, Sara Elezovic
    Pogorelic, Zenon
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2020, 30 (01): : 76 - 80
  • [8] A Comparison of Tracheal Intubation with Ambu® AuraGain™, Fastrach® and BlockBuster® Laryngeal Mask Airway: A Randomised Clinical Trial
    Raiger, L. K.
    Sharma, Bhawesh
    Gehlot, Ravindra Kumar
    Dhania, Swati
    Meena, Hemant Kumar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (09) : UC14 - UC18
  • [9] Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial
    Trevisanuto, Daniele
    Cavallin, Francesco
    Loi Ngoc Nguyen
    Tien Viet Nguyen
    Linh Dieu Tran
    Chien Dinh Tran
    Doglioni, Nicoletta
    Micaglio, Massimo
    Moccia, Luciano
    JOURNAL OF PEDIATRICS, 2015, 167 (02) : 286 - +
  • [10] Desflurane versus sevoflurane in pediatric anesthesia with a laryngeal mask airway A randomized controlled trial
    Kim, Eun-Hee
    Song, In-Kyung
    Lee, Ji-Hyun
    Kim, Hee-Soo
    Kim, Hyun-Chang
    Yoon, Soo-Hyuk
    Jang, Young-Eun
    Kim, Jin-Tae
    MEDICINE, 2017, 96 (35)