A Simulation Model for the Handheld Ultrasound Diagnosis of Pediatric Forearm Fractures

被引:1
|
作者
Eksioglu, Merve [1 ]
Azapoglu Kaymak, Burcu [1 ]
机构
[1] Univ Hlth Sci, Fatih Sultan Mehmet Educ & Res Hosp, Dept Emergency Med, Istanbul, Turkiye
关键词
handheld ultrasound; pediatric forearm fracture; pocket sized ultrasound; point-of-care ultrasound; ultrasound simulation; POCKET-SIZED ULTRASOUND; OF-CARE ULTRASOUND; MEDICAL-EDUCATION; CHILDREN; RADIUS;
D O I
10.1017/S1049023X23006349
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:Handheld ultrasound (HHU) devices have gained prominence in emergency care settings and post-graduate training, but their application in the diagnosis of pediatric fractures remains under-explored. The aim of this study is to evaluate the effectiveness and accuracy of an HHU device for diagnosing pediatric forearm fractures using a simulation model.Methods:The materials for the basic pediatric fracture model include turkey bones soaked in white vinegar to make them pliable, food-grade gelatine, and plastic containers. Ultrasound analysis of the models was done with an HHU device, Sonosite IViz US (FUJIFILM Sonosite, Inc.; Bothell, Washington USA). Four different fracture patterns (transverse fracture, oblique fracture, greenstick fracture, and a torus fracture) and one model without fracture were used in this study. Twenty-six Emergency Medicine residents sonographically evaluated different bone models in order to define the presence and absence of fracture and the fracture subtype. The participants' ability to obtain adequate images and the time taken to create and recognize the images were evaluated and recorded. After the sonographic examination, the residents were also asked for their opinion on the model as a teaching tool.Results:All participants (100%) recognized the normal bone model and the fracture, regardless of the fracture type. The consistency analysis between the practitioners indicated a substantial agreement (weighted kappa value of 0.707). The duration to identify the target pathology in fracture models was significantly longer for the greenstick fracture (78.57 [SD = 30.45] seconds) model compared to other models. The majority of participants (92.3%) agreed that the model used would be a useful teaching tool for learning ultrasound diagnosis of pediatric forearm fractures.Conclusions:All participants successfully identified both the normal bone model and the presence of fractures, irrespective of the fracture type. Significantly, the identification of the greenstick fracture took longer compared to other fracture types. Moreover, the majority of participants acknowledged the model's utility as a teaching tool for learning ultrasound diagnosis of pediatric forearm fractures.
引用
收藏
页码:589 / 594
页数:6
相关论文
共 50 条
  • [41] Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model
    Johnson G.G.R.J.
    Zeiler F.A.
    Unger B.
    Hansen G.
    Karakitsos D.
    Gillman L.M.
    Critical Ultrasound Journal, 2016, 8 (1)
  • [42] The Association of Metal Frame Construct of ESIN and radiographic bone healing of pediatric forearm fractures
    Linda, Korhonen
    Nicolas, Lutz
    Juha-Jaakko, Sinikumpu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 856 - 862
  • [43] Cast indexing predicting outcome of proximal pediatric forearm fractures
    Sheikh, Hassaan Qaiser
    Malhotra, Karan
    Wright, Phil
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (04) : 398 - 402
  • [44] Failure Predictor Factors of Conservative Treatment in Pediatric Forearm Fractures
    Maccagnano, G.
    Notarnicola, A.
    Pesce, V
    Tafuri, S.
    Mudoni, S.
    Nappi, V
    Moretti, B.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [45] Ultrasound diagnosis of supracondylar fractures in children
    Eckert, K.
    Janssen, N.
    Ackermann, O.
    Schweiger, B.
    Radeloff, E.
    Liedgens, P.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2014, 40 (02) : 159 - 168
  • [46] Ultrasound diagnosis of supracondylar fractures in children
    K. Eckert
    N. Janssen
    O. Ackermann
    B. Schweiger
    E. Radeloff
    P. Liedgens
    European Journal of Trauma and Emergency Surgery, 2014, 40 : 159 - 168
  • [47] Comparison of Above- and Below-Elbow Casting for Pediatric Distal Metaphyseal Forearm Fractures
    Schreck, Michael J.
    Hammert, Warren C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (02): : 347 - 349
  • [48] Accuracy of point-of-care ultrasound for determining the adequacy of pediatric forearm fracture reductions
    Sik, Nihan
    Ozturk, Ali
    Kosay, Mustafa Can
    Yilmaz, Durgul
    Duman, Murat
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 48 : 243 - 248
  • [49] Risk Factors for Redisplacement of Pediatric Distal Forearm and Distal Radius Fractures
    McQuinn, Alexander Geoffrey
    Jaarsma, Ruurd Lukas
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2012, 32 (07) : 687 - 692
  • [50] Intramedullary Implant Choice and Cost in the Treatment of Pediatric Diaphyseal Forearm Fractures
    Heare, Austin
    Goral, Dawn
    Belton, Matthew
    Beebe, Corey
    Trizno, Anastasiya
    Stoneback, Jason
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (10) : E334 - E338