Comparison of re-revision rate and radiological outcomes between Kerboull-type plate and metal mesh with impaction bone grafting for revision total hip arthroplasty

被引:2
|
作者
Ishizu, Hotaka [1 ,2 ]
Shimizu, Tomohiro [1 ,2 ]
Sasazawa, Fumio [3 ]
Takahashi, Daisuke [1 ,2 ]
Terkawi, Mohamad Alaa [1 ,2 ]
Takahashi, Kaname [3 ]
Ohashi, Yusuke [3 ]
Kanayama, Masahiro [3 ]
Iwasaki, Norimasa [1 ,2 ]
机构
[1] Hokkaido Univ, Fac Med, Dept Orthopaed Surg, Kita 15 Nishi 7,Kita Ku, Sapporo 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Kita 15 Nishi 7,Kita Ku, Sapporo 0608638, Japan
[3] Hakodate Cent Gen Hosp, Dept Orthopaed Surg, Hon Cho 33-2, Hakodate 0408585, Japan
关键词
Kerboull-type plate; Revision total hip arthroplasty; Metal mesh; Impaction bone grafting; Vertical defect height; ACETABULAR REINFORCEMENT DEVICE; FOLLOW-UP; RECONSTRUCTION; ALLOGRAFT; CLASSIFICATION; REPLACEMENT; DEFECTS;
D O I
10.1186/s12891-023-06240-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThis study compared the re-revision rate and radiographic outcomes of revision total hip arthroplasty (THA) using a Kerboull-type acetabular reinforcement device (KT plate) with bulk structural allograft and metal mesh with impaction bone grafting (IBG).MethodsNinety-one hips of 81 patients underwent revision THA for American Academy of Orthopedic Surgeons (AAOS) classification type III defects from 2008 to 2018. Of these, seven hips of five patients and 15 hips of 13 patients were excluded due to insufficient follow-up information (< 24 months) and large bone defects with a vertical defect height >= 60 mm, respectively. The current study compared the survival and radiographic parameters of 45 hips of 41 patients using a KT plate (KT group) and 24 hips of 24 patients using a metal mesh with IBG (mesh group).ResultsEleven hips (24.4%) in the KT group and 1 hip (4.2%) in the mesh group exhibited radiological failure. Moreover, 8 hips in the KT group (17.0%) required a re-revision THA, while none of the patients in the mesh group required a re-revision. The survival rate with radiographic failure as the endpoint in the mesh group was significantly higher than that in the KT group (100% vs 86.7% at 1-year and 95.8% vs 80.0% at 5-years, respectively; p = 0.032). On multivariable analysis evaluating factors associated with radiographic failure, there were no significant associations with any radiographic measurement. Of the 11 hips with radiographic failure, 1 (11.1%), 3 (12.5%), and 7 (58.3%) hips were of Kawanabe classification stages 2, 3, and 4, respectively.ConclusionsThe findings of this study suggest that revision THA using KT plates with bulk structure allografts could provide poorer clinical outcomes than revision THA using a metal mesh with IBG. Although revision THA using KT plates with bulk structural allografts could set the true hip center, there is no association between a high hip center and clinical outcomes. The relationship between the position of the KT plate and the host bone might be considered more carefully.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] Comparison of re-revision rate and radiological outcomes between Kerboull-type plate and metal mesh with impaction bone grafting for revision total hip arthroplasty
    Hotaka Ishizu
    Tomohiro Shimizu
    Fumio Sasazawa
    Daisuke Takahashi
    Mohamad Alaa Terkawi
    Kaname Takahashi
    Yusuke Ohashi
    Masahiro Kanayama
    Norimasa Iwasaki
    BMC Musculoskeletal Disorders, 24
  • [2] Impaction bone grafting in hip re-revision surgery BONE STOCK RESTORATION AND RADIOLOGICAL MIGRATION OF THE ACETABULAR COMPONENT
    Garcia-Rey, E.
    Saldana, L.
    Garcia-Cimbrelo, E.
    BONE & JOINT JOURNAL, 2021, 103B (03) : 492 - 499
  • [3] Revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device and allogeneic structural bone graft
    Fujimoto, Yusuke
    Nakamura, Shunsuke
    Ijuin, Toshiro
    Iuchi, Tomohiro
    Nakajo, Masahide
    Taniguchi, Noboru
    JOURNAL OF ORTHOPAEDIC SURGERY, 2022, 30 (02)
  • [4] Risk factors for failure of revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device
    Hayashi, Shinya
    Nishiyama, Takayuki
    Hashimoto, Shingo
    Matsumoto, Tomoyuki
    Takayama, Koji
    Ishida, Kazunari
    Nishida, Kotaro
    Kuroda, Ryosuke
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [5] Posterior versus direct anterior approach in revision hip arthroplasty using Kerboull-type plate
    Baba, Tomonori
    Homma, Yasuhiro
    Jinnai, Yuta
    Tanabe, Hiroki
    Banno, Sammy
    Watari, Taiji
    Kaneko, Kazuo
    SICOT-J, 2020, 6
  • [6] Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups
    Assi, Chahine
    Caton, Jacques
    Fawaz, Wissam
    Samaha, Camille
    Yammine, Kaissar
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) : 2245 - 2251
  • [7] Results of Wagner SL revision stem with impaction bone grafting in revision total hip arthroplasty
    Singh, Somesh P.
    Bhalodiya, Haresh P.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (04) : 357 - 363
  • [8] Cancellous Impaction Bone Grafting of Acetabular Defects in Complex Primary and Revision Total Hip Arthroplasty
    Patil, Nilesh
    Hwang, Katherine
    Goodman, Stuart B.
    ORTHOPEDICS, 2012, 35 (03) : E306 - E312
  • [9] Risk factors for failure of revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device
    Shinya Hayashi
    Takayuki Nishiyama
    Shingo Hashimoto
    Tomoyuki Matsumoto
    Koji Takayama
    Kazunari Ishida
    Kotaro Nishida
    Ryosuke Kuroda
    BMC Musculoskeletal Disorders, 18
  • [10] Mid- to Long-term Follow-up of Severe Acetabular Bone Defect after Revision Total Hip Arthroplasty Using Impaction Bone Grafting and Metal Mesh
    Yang, Chao
    Zhu, Kechao
    Dai, Huiyong
    Zhang, Xianlong
    Wang, Qiaojie
    Wang, Qi
    ORTHOPAEDIC SURGERY, 2023, 15 (03) : 750 - 757