Evaluation of Patient-Specific Quality Assurance for RapidArc Treatment Delivery Using Dose Volume Histogram

被引:0
作者
Manna, Sumanta [1 ,2 ]
Singh, Benoy Kumar [1 ]
Das, K. J. Maria [3 ]
机构
[1] GLA Univ, Dept Phys, Mathura, Uttar Pradesh, India
[2] Kalyan Singh Super Specialty Canc Inst, Specialty Med Phys, Lucknow, Uttar Pradesh, India
[3] Sanjay Gandhi Postgrad Inst Med Sci, Dept Radiotherapy, Lucknow, Uttar Pradesh, India
关键词
DVH; PSQA; Radiotherapy; Action Level; RapidArc;
D O I
暂无
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This study aims to evaluate the application of dose volume histogram (DVH) metrics within the patient-specific quality assurance (PSQA) protocol in various sites for RapidArc treatment delivery. Forty patients were included in this study, of which twenty each Head and Neck (H&N) and Pelvis Rapid Arc plans were evaluated. Octavius 4D 1500 detector array with vented parallel plate ion chambers was used for this study, which reconstruct the pre-treatment measured doses into threedimensional (3D) during pre-treatment quality assurance. The verisoft DVH application was utilized to estimate the dose administered to the patient's volume, explicitly focusing on the errors associated in the DVH. The measured data were compared with the treatment planning system created verification plan. Three-dimensional local and global gamma were evaluated using different gamma criteria of 3 mm/3%, 3 mm/2%, 2 mm/3% and 2 mm/2%, respectively. In addition, the agreement score was analysed for axial, coronal, and sagittal planes in addition to the volumetric analysis. All plans meet the action level requirement of > 95% with 3%/3 mm gamma acceptance criteria. In addition, the DVH demonstrated that the doses administered to the target volumes and organs at risk remained within the specified dose tolerances for all cases. The DVH analysis will be applied to identify the instances where patient dose errors surpass the predetermined established action threshold. The gamma index did not initially identify these and may have utility in determining the reason for failed plans. Further, it enables identifying and managing dose errors associated with the patient's anatomy. Finally, this study has showcased the incorporation of DVH metrics into RapidArc PSQA protocol may deliver clinically meaningful outcomes in close proximity to the gamma index.
引用
收藏
页码:S14 / S22
页数:9
相关论文
共 15 条
  • [1] Assessment of using a gamma index analysis for patient-specific quality assurance in Japan
    Anetai, Yusuke
    Sumida, Iori
    Kumazaki, Yu
    Kito, Satoshi
    Kurooka, Masahiko
    Ueda, Yoshihiro
    Otani, Yuki
    Narita, Yuichiro
    Kawamorita, Ryu
    Akita, Kazuhiko
    Kato, Takahiro
    Nakamura, Mitsuhiro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (10):
  • [2] Ansari S, 2019, Iran J Med Phys., V16, P139
  • [3] Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics
    Coleman, Linda
    Skourou, Christina
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [4] Das S, 2022, Cureus, V14
  • [5] Douama S, 2021, Onkol i Radioter., V15, P5
  • [6] Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram
    Low, Christopher
    Toye, Warren
    Phung, Peter
    Huston, Christopher
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 112 - 118
  • [7] A technique for the quantitative evaluation of dose distributions
    Low, DA
    Harms, WB
    Mutic, S
    Purdy, JA
    [J]. MEDICAL PHYSICS, 1998, 25 (05) : 656 - 661
  • [8] Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218
    Miften, Moyed
    Olch, Arthur
    Mihailidis, Dimitris
    Moran, Jean
    Pawlicki, Todd
    Molineu, Andrea
    Li, Harold
    Wijesooriya, Krishni
    Shi, Jie
    Xia, Ping
    Papanikolaou, Nikos
    Low, Daniel A.
    [J]. MEDICAL PHYSICS, 2018, 45 (04) : E53 - E83
  • [9] Dosimetric Verification by Using the ArcCHECK System and 3DVH Software for Various Target Sizes
    Song, Jin Ho
    Shin, Hun-Joo
    Kay, Chul Seung
    Son, Seok Hyun
    [J]. PLOS ONE, 2015, 10 (03):
  • [10] Pretreatment patient-specific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogram
    Stasi, M.
    Bresciani, S.
    Miranti, A.
    Maggio, A.
    Sapino, V.
    Gabriele, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (12) : 7626 - 7634