Background: In pure tone audiometry, when the difference of the Average Air Conduction Threshold of pure tone (AACT) between bilateral ears is more than 40 dB HL masking must be performed on the poor side, However, we found that masking also make significance difference when the binaural AACT difference (AACT-d)was less than 40 dB HL in some patients.Aims/Objective: Assessing the significance of masking for the poor ear in pure tone audiometry in patients with different types of deafness to obtain preoperative accurate hearing.Material and methods: A comparative analysis of 163 cases (163 ears) with hearing difference between two ears was conducted, who were divided into three groups: G1 Congenital Malformation of the Middle and Outer Ear (CMMOE)as conductive deafness, 63 ears, G2 sudden deafness as sensorineural deafness, 65 ears, and G3 media otitis as conductive or mixed deafness,35 ears. AACT-d before and after the poor ear masking was analyzed under the following three conditions: (1) 0.125-8 KHz each frequency, (2) 0.5-4 KHz on average, (3) the frequencies of AACT-d >= 40 dB HL and <40 dB HL between the two ears before masking. If the sample data did not follow a normal distribution, the Wilcoxon rank sum test was used for comparasion of AACT, and p < 0.05 was considered statistically significant. It is clinically effective for AACT-d >= 15 dB HL at 1 frequency or 10 dB HL <= AACT-d at 2 frequencies <15 dB HL before and after masking.Results: Among the three groups, (1) the comparasion of AACT-d before and after the poor ear masking for each frequency of 0.125-8 KHz and 0.5-4 KHz on average with all p < 0.05, and the AACT-d of the G1 group was the largest, with an average 0.5-4KHz of 7.5 dB HL, and the first two were 14.5 dB HL and 13.8 dB HL at 0.125 KHz and 0.25 KHz, respectively. (2) AACT-d >= 40 dB HL and <40 dB HL between the two ears before masking were distributed at the full frequency of 0.125-8KHz, the clinically effective rates of >= 40 dB HL groups were G1 (89.3%), G2 (45.5%) and G3 (5.3%), while those of < 40 dB HL groups were G1 (69.7%), G2 (34.4%) and G3 (31.3%), respectively.Conclusion and significance: For all three groups, there was statistically significant in AACT-d before and after the poor ear masking across each frequency of 0.125-8 KHz and on average 0.5-4 KHz. The distribution of AACT-d >= 40 dB HL and <40 dB HL between the two ears before masking was observed throughout the full frequency range of 0.125-8 KHz. AACT-d before and after the poor ear masking showed clinical effectiveness in all three groups, with the highest effective rate observed in the G1 group and the highest AACT-d at 0.125 KHz and 0.25 KHz. Therefore, regardless of whether the AACT-d between the two ears before masking is >= 40 dB HL or <40 dB HL, the full frequency masking should be employed in three groups, especially for the G1 group of CMMOE, particularly at 0.125 KHz and 0.25 KHz.
引用
收藏
页码:S34 / S38
页数:5
相关论文
共 50 条
  • [1] The Importance of Considering the Minimum Interaural Attenuation Value in the Masking Procedure of Pure-Tone Audiometry
    Zakaria, Mohd
    INDIAN JOURNAL OF OTOLOGY, 2022, 28 (02) : 153 - 155
  • [2] Assessment of hearing loss by pure-tone audiometry in patients with mucopolysaccharidoses
    Lin, Hsiang-Yu
    Shih, Shou-Chuan
    Chuang, Chih-Kuang
    Lee, Kuo-Sheng
    Chen, Ming Ren
    Lin, Hung-Ching
    Chiu, Pao Chin
    Niu, Dau-Ming
    Lin, Shuan-Pei
    MOLECULAR GENETICS AND METABOLISM, 2014, 111 (04) : 533 - 538
  • [3] Pure tone audiometry in children
    Kemaloglu, YK
    Gündüz, B
    Gökmen, S
    Yilmaz, M
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2005, 69 (02) : 209 - 214
  • [4] Self-assessment of bone conduction hearing threshold using mobile audiometry: comparison with pure tone audiometry
    Masalski, Marcin
    Turski, Marcin
    Zatonski, Tomasz
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (07) : 535 - 542
  • [5] Self-assessment of bone conduction hearing threshold using mobile audiometry: comparison with pure tone audiometry
    Masalski, Marcin
    Turski, Marcin
    Zatonski, Tomasz
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (07) : 535 - 542
  • [6] Pure Tone Audiometry in Anemia Patients
    Prabakaran S.
    Adithya V.
    Namasivaya Navin R.B.
    Rajasekaran S.
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2024, 76 : 1711 - 1715
  • [7] Pure Tone Audiometry in Anemia Patients
    Prabakaran, S.
    Adithya, V
    Navin, R. B. Namasivaya
    Rajasekaran, S.
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 76 (2) : 1711 - 1715
  • [8] Pure Tone Audiometry and Hearing Loss in Alzheimer's Disease: A Meta-Analysis
    Kwok, Susanna S.
    Nguyen, Xuan-Mai T.
    Wu, Diana D.
    Mudar, Raksha A.
    Llano, Daniel A.
    FRONTIERS IN PSYCHOLOGY, 2022, 12
  • [9] The limitations of pure-tone audiometry (as the gold standard test of hearing) that are worthy of consideration
    Zakaria, Mohd Normani
    INDIAN JOURNAL OF OTOLOGY, 2021, 27 (01) : 1 - 2
  • [10] Comparison of pure tone audiometry and auditory steady-state responses in subjects with normal hearing and hearing loss
    Ali Ozdek
    Mahmut Karacay
    Guleser Saylam
    Emel Tatar
    Nurdan Aygener
    Mehmet Hakan Korkmaz
    European Archives of Oto-Rhino-Laryngology, 2010, 267 : 43 - 49