Use of the Wearable Cardioverter-Defibrillator Among Patients With Myocarditis and Reduced Ejection Fraction or Ventricular Tachyarrhythmia: Data From a Multicenter Registry

被引:7
作者
El-Battrawy, Ibrahim [1 ,2 ]
Koepsel, Katharina [1 ]
Tenbrink, David [1 ]
Kovacs, Boldizsar [3 ]
Dreher, Tobias C. [4 ]
Blockhaus, Christian [6 ,7 ]
Gotzmann, Michael [8 ]
Klein, Norbert [9 ]
Kuntz, Thomas [9 ]
Shin, Dong-In [6 ,7 ]
Lapp, Hendrik [10 ]
Rosenkaimer, Stephanie [4 ]
Abumayyaleh, Mohammad [4 ,5 ]
Hamdani, Nazha [2 ]
Saguner, Ardan Muammer [3 ]
Kowitz, Jacqueline [4 ]
Erath, Julia W. [11 ]
Duru, Firat [3 ]
Muegge, Andreas [1 ]
Akin, Ibrahim [4 ,5 ]
Aweimer, Assem [1 ]
Beiert, Thomas [10 ]
机构
[1] Ruhr Univ Bochum, Bergmannsheil Univ Hosp, Dept Cardiol & Angiol, Bochum, Germany
[2] Ruhr Univ Bochum, Inst Forsch & Lehre IFL, Dept Mol & Expt Cardiol, Bochum, Germany
[3] Univ Zurich Hosp, Univ Heart Ctr, Dept Cardiol, Zurich, Switzerland
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Cardiol Angiol Haemostaseol & Med Intens Car, Mannheim, Germany
[5] German Ctr Cardiovasc Res DZHK, Partner Site Heidelberg Mannheim, Mannheim, Germany
[6] Helios Clin Krefeld, Dept Cardiol, Heart Ctr Niederrhein, Krefeld, Germany
[7] Univ Witten Herdecke, Sch Med, Fac Hlth, Witten, Germany
[8] Ruhr Univ Bochum, Univ Hosp St Josef Hosp Bochum, Cardiol & Rhythmol, Bochum, Germany
[9] Klinikum St Georg gGmbH Leipzig, Dept Cardiol Angiol & Internal Intens Care Med, Leipzig, Germany
[10] Univ Hosp Bonn, Dept Internal Med 2, Heart Ctr Bonn, Bonn, Germany
[11] Goethe Univ, Frankfurt Univ Hosp, Dept Cardiol, Frankfurt, Germany
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2023年 / 12卷 / 18期
关键词
myocarditis; sudden cardiac death; ventricular tachycardia; wearable cardioverter-defibrillator; HIGH-RISK; EXPERIENCE; ARRHYTHMIAS;
D O I
10.1161/JAHA.123.030615
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Data on the use of the wearable cardioverter-defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results: In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.616.3years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin-converting enzyme inhibitors (62.5%), angiotensin-receptor-neprilysin inhibitor (22.9%), aldosterone-antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%-45%) and increased to 48% (39%-55%) over long-term follow-up (P<0.001). The median BNP (brain natriuretic peptide) level at baseline was 1702pg/mL (565-3748) and decreased to 188pg/mL (26-348) over long-term follow-up (P=0.022). The mean wear time was 79.7 +/- 52.1days and 21.0 +/- 4.9hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions: Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Efficacy of an implantable cardioverter-defibrillator in patients with diabetes and heart failure and reduced ejection fraction
    Rasmus Rørth
    Pooja Dewan
    Søren Lund Kristensen
    Pardeep S. Jhund
    Mark C. Petrie
    Lars Køber
    John J. V. McMurray
    Clinical Research in Cardiology, 2019, 108 : 868 - 877
  • [12] Efficacy of an implantable cardioverter-defibrillator in patients with diabetes and heart failure and reduced ejection fraction
    Rorth, Rasmus
    Dewan, Pooja
    Kristensen, Soren Lund
    Jhund, Pardeep S.
    Petrie, Mark C.
    Kober, Lars
    McMurray, John J. V.
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (08) : 868 - 877
  • [13] Age differences of patients treated with wearable cardioverter defibrillator: Data from a multicentre registry
    El-Battrawy, Ibrahim
    Tenbrink, David
    Kovacs, Boldizsar
    Dreher, Tobias C.
    Blockhaus, Christian
    Klein, Norbert
    Shin, Dong-In
    Hijazi, Mido
    Rosenkaimer, Stephanie
    Beiert, Thomas
    Abumayyaleh, Mohammad
    Saguner, Ardan Muammer
    Kowitz, Jacqueline
    Erath, Julia W.
    Duru, Firat
    Muegge, Andreas
    Aweimer, Assem
    Akin, Ibrahim
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2023, 53 (07)
  • [14] Cardioverter-defibrillator does not improve short-term survival among patients with non-ischemic cardiomyopathy and reduced left ventricular ejection fraction
    Jilek, Clemens
    Lewalter, Thorsten
    Pauschinger, Matthias
    von Scheidt, Wolfgang
    Frankenstein, Lutz
    Pfister, Otmar
    Hambrecht, Rainer
    Bruder, Oliver
    Brachmann, Johannes
    Hartmann, Andreas
    Strasser, Ruth
    Hochadel, Matthias
    Senges, Jochen
    CLINICAL RESEARCH IN CARDIOLOGY, 2020, 109 (01) : 115 - 123
  • [15] Extended Use of the Wearable Cardioverter-Defibrillator: Which Patients Are Most Likely to Benefit?
    Kovacs, Boldizsar
    Reek, Sven
    Krasniqi, Nazmi
    Eriksson, Urs
    Duru, Firat
    CARDIOLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [16] Ventricular tachyarrhythmia recurrence in primary versus secondary implantable cardioverter-defibrillator patients and role of electrophysiology study
    Zaman, Sarah
    Sivagangabalan, Gopal
    Chik, William
    Stafford, Wayne
    Hayes, John
    Denman, Russell
    Young, Glenn
    Sanders, Prashanthan
    Kovoor, Pramesh
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (03) : 195 - 202
  • [17] Incidence of Appropriate Shock in Implantable Cardioverter-Defibrillator Patients With Improved Ejection Fraction
    Naksuk, Niyada
    Saab, Ali
    Li, Jian-Ming
    Florea, Viorel
    Akkaya, Mehmet
    Anand, Inder S.
    Benditt, David G.
    Adabag, Selcuk
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (06) : 426 - 430
  • [18] Wearable cardioverter defibrillator after ICD-system explantation: data from a multicenter registry
    El-Battrawy, Ibrahim
    Beiert, Thomas
    Koepsel, Katharina
    Kovacs, Boldizsar
    Dreher, Tobias C.
    Blockhaus, Christian
    Tenbrink, David
    Klein, Norbert
    Kuntz, Thomas
    Lapp, Hendrik
    Shin, Dong-In
    Abumayyaleh, Mohammad
    Saguner, Ardan Muammer
    Hijazi, Mido
    Erath, Julia W.
    Duru, Firat
    Muegge, Andreas
    Akin, Ibrahim
    Aweimer, Assem
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [19] Association of device detected atrial and ventricular tachyarrhythmia with adverse events in patients with an implantable cardioverter-defibrillator
    Abbas, Hassan
    Younis, Arwa
    Goldenberg, Ilan
    McNitt, Scott
    Aktas, Mehmet K.
    Tabaja, Chadi
    Ojo, Amole
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1203 - 1211
  • [20] Use of implantable cardioverter-defibrillator in children supported with ventricular assist device: An analysis of data from teh EUROMACS registry
    Schweiger, Martin
    Amodeo, Antonio
    Vierecke, Juliane
    Hussein, Hina
    Berger, Florian
    de By, Theo M. M. H.
    Zimpfer, Daniel
    Sliwka, Joanna
    Davies, Ben
    Miera, Oliver
    Meyns, Bart
    ARTIFICIAL ORGANS, 2023, 47 (08) : 1319 - 1325