Stadium-type resonator sensor based on a multi-mode waveguide with mode discrimination phenomenon

被引:0
作者
Lee, Jae-Sang [1 ]
Kim, Yong-Jin [1 ]
Cho, Seong-Hyeon [1 ]
Park, Byeong-Tak [1 ]
Choi, Woo June [1 ]
Choi, Young-Wan [1 ]
机构
[1] Chung Ang Univ, Dept Elect & Elect Engn, Adv Photon Lab, Seoul 06974, South Korea
基金
新加坡国家研究基金会;
关键词
REFRACTIVE-INDEX; TEMPERATURE; INTERFEROMETER;
D O I
10.1364/OE.489554
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, we present a multi-mode resonator based on SU-8 polymer and experimentally verify that the resonator showed mode discrimination can be used as a sensor with high performance. According to field emission scanning electron microscopy (FE-SEM) images, the fabricated resonator shows sidewall roughness which is canonically considered to be undesirable after a typical development process. In order to analyze the effect of sidewall roughness, we conduct the resonator simulation considering the roughness under various conditions. Mode discrimination still occurs even in the presence of sidewall roughness. In addition, waveguide width controllable by UV exposure time effectively contributes to mode discrimination. To verify the resonator as a sensor, we perform a temperature variation experiment, which results in a high sensitivity of about 630.8 nm/RIU. This result shows that the multi-mode resonator sensor fabricated via a simple process is competitive with other single-mode waveguide sensors.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:19843 / 19852
页数:10
相关论文
共 19 条
[1]   Highly sensitive refractive index sensor based on hybrid plasmonic waveguide microring resonator [J].
Butt, M. A. ;
Khonina, S. N. ;
Kazanskiy, N. L. .
WAVES IN RANDOM AND COMPLEX MEDIA, 2020, 30 (02) :292-299
[2]   Compact Microring Resonator With 2 x 2 Tapered Multimode Interference Couplers [J].
Dai, Daoxin ;
Yang, Liu ;
Sheng, Zhen ;
Yang, Bo ;
He, Sailing .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (21) :4878-4883
[3]  
Duque T., 2013, STATE ART BIOSENSORS
[4]   Rapid Detection of Coronavirus (COVID-19) Using Microwave Immunosensor Cavity Resonator [J].
Elsheakh, Dalia M. ;
Ahmed, Mohamed I. ;
Elashry, Gomaa M. ;
Moghannem, Saad M. ;
Elsadek, Hala A. ;
Elmazny, Waleed N. ;
Alieldin, Nelly H. ;
Abdallah, Esmat A. .
SENSORS, 2021, 21 (21)
[5]   Integrated humidity sensor based on SU-8 polymer microdisk microresonator [J].
Eryurek, M. ;
Tasdemir, Z. ;
Karadag, Y. ;
Anand, S. ;
Kilinc, N. ;
Alaca, B. E. ;
Kiraz, A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 :1115-1120
[6]   Optical temperature sensor with enhanced sensitivity by employing hybrid waveguides in a silicon Mach-Zehnder interferometer [J].
Guan, Xiaowei ;
Wang, Xiaoyan ;
Frandsen, Lars H. .
OPTICS EXPRESS, 2016, 24 (15) :16349-16356
[7]   Simulation and Analysis of Single-Mode Microring Resonators in Lithium Niobate Thin Films [J].
Han, Huangpu ;
Xiang, Bingxi ;
Zhang, Jiali .
CRYSTALS, 2018, 8 (09)
[8]   MODE DISPERSION IN DIFFUSED CHANNEL WAVEGUIDES BY EFFECTIVE INDEX METHOD [J].
HOCKER, GB ;
BURNS, WK .
APPLIED OPTICS, 1977, 16 (01) :113-118
[9]  
Ibrahim M., 2010, OPT EXPRESS, V18, P20251
[10]   Simultaneous measurement of refractive index and temperature using a Mach-Zehnder interferometer with forward core-cladding-core recoupling [J].
Jiao, Tao ;
Meng, Hongyun ;
Deng, Shuying ;
Liu, Shuai ;
Wang, Xianjun ;
Wei, Zhongchao ;
Wang, Faqiang ;
Tan, Chunhua ;
Huang, Xuguang .
OPTICS AND LASER TECHNOLOGY, 2019, 111 :612-615