24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression

被引:7
作者
Gaboriau, Thibaut [1 ]
Dubois, Remi [2 ]
Foucque, Boris [1 ]
Malet, Florence [1 ]
Schweitzer, Cedric [1 ,3 ,4 ]
机构
[1] CHU Bordeaux, Dept Ophthalmol, Bordeaux, France
[2] Hop Xavier ArnozanPessac, Electrophysiol & Heart Modeling Inst, IHU Liryc, Pessac, France
[3] Univ Bordeaux, Bordeaux Populat Hlth Res Ctr, Team LEHA, Inserm,UMR 1219, Bordeaux, France
[4] Univ Hosp Pellegrin, Ophthalmol, Pl Amelie Raba Leon, F-33076 Bordeaux, France
关键词
glaucoma; intraocular pressure (IOP); contact lens sensor (CLS); visual field; glaucoma progression; circadian rhythm; VISUAL-FIELD CHANGE; NORMAL-TENSION GLAUCOMA; PRIMARY OPEN-ANGLE; UNTREATED PATIENTS; RATES; REDUCTION; PATTERNS;
D O I
10.1167/iovs.64.3.3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to compare 24-hour intraocular pressure (IOP) related fluctuations monitoring between 2 groups of visual field progression rates in patients with open angle glaucoma (OAG). METHODS. Cross-sectional study performed at Bordeaux University Hospital. Twenty -four-hour monitoring was performed using a contact lens sensor (CLS; Triggerfish; SENSIMED, Etagnieres, Switzerland). Progression rate was calculated using a linear regression of the mean deviation (MD) parameter of the visual field test (Octopus; HAAG-STREIT, Switzer-land). Patients were allocated into two groups: group 1 with an MD progression rate <-0.5 dB/year and group 2 with an MD progression rate >=-0.5 dB/year. An automatic signal-processing program was developed and a frequency filtering of the monitoring by wavelet transform analysis was used to compare the output signal between the two groups. A multivariate classifier was performed for prediction of the faster progression group. RESULTS. Fifty-four eyes of 54 patients were included. The mean progression rate was -1.09 +/- 0.60 dB/year in group 1 (n = 22) and -0.12 +/- 0.13 dB/year in group 2 (n = 32). Twenty-four-hour magnitude and absolute area under the monitoring curve were significantly higher in group 1 than in group 2 (group 1: 343.1 +/- 62.3 millivolts [mVs] and 8.28 +/- 2.10 mVs, respectively, group 2: 274.0 +/- 75.0 mV and 6.82 +/- 2.70 mVs respectively, P < 0.05). Magnitude and area under the wavelet curve for short frequency periods ranging from 60 to 220 minutes were also significantly higher in group 1 (P < 0.05). CONCLUSIONS. The 24-hour IOP related fluctuations characteristics, as assessed by a CLS, may act as a risk factor for progression in OAG. In association with other predictive factors of glaucoma progression, the CLS may help adjust treatment strategy earlier.
引用
收藏
页数:9
相关论文
共 40 条
[1]   Circadian intraocular pressure patterns in healthy subjects, primary open angle and normal tension glaucoma patients with a contact lens sensor [J].
Agnifili, Luca ;
Mastropasqua, Rodolfo ;
Frezzotti, Paolo ;
Fasanella, Vincenzo ;
Motolese, Ilaria ;
Pedrotti, Emilio ;
Di Iorio, Angelo ;
Mattei, Peter A. ;
Motolese, Eduardo ;
Mastropasqua, Leonardo .
ACTA OPHTHALMOLOGICA, 2015, 93 (01) :E14-E21
[2]  
Alward WL, 1998, AM J OPHTHALMOL, V126, P498
[3]   24-h monitoring devices and nyctohemeral rhythms of intraocular pressure [J].
Aptel, Florent ;
Weinreb, Robert N. ;
Chiquet, Christophe ;
Mansouri, Kaweh .
PROGRESS IN RETINAL AND EYE RESEARCH, 2016, 55 :108-148
[4]   Detecting Visual Field Progression [J].
Aref, Ahmad A. ;
Budenz, Donald L. .
OPHTHALMOLOGY, 2017, 124 (12) :S51-S56
[5]   Mathematical modeling of circadian rhythms [J].
Asgari-Targhi, Ameneh ;
Klerman, Elizabeth B. .
WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE, 2019, 11 (02)
[6]   Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma [J].
Barkana, Yaniv ;
Anis, Sarah ;
Liebmann, Jeffrey ;
Tello, Celso ;
Ritch, Robert .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) :793-797
[7]   Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial [J].
Bengtsson, Boel ;
Leske, M. Cristina ;
Hyman, Leslie ;
Heijl, Anders .
OPHTHALMOLOGY, 2007, 114 (02) :205-209
[8]  
Boodhna T, 2015, EYE, V29, P1613, DOI 10.1038/eye.2015.161
[9]   Intraocular pressure fluctuation - A risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study [J].
Caprioli, Joseph ;
Coleman, Anne L. .
OPHTHALMOLOGY, 2008, 115 (07) :1123-1129
[10]   Practical recommendations for measuring rates of visual field change in glaucoma [J].
Chauhan, B. C. ;
Garway-Heath, D. F. ;
Goni, F. J. ;
Rossetti, L. ;
Bengtsson, B. ;
Viswanathan, A. C. ;
Heijl, A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (04) :569-573