EUS-guided fine-needle biopsy sampling of solid pancreatic tumors with 3 versus 12 to-and-fro movements: a multicenter prospective randomized controlled study

被引:7
作者
Takahashi, Kosuke [1 ,3 ]
Yasuda, Ichiro [1 ]
Hayashi, Nobuhiko [1 ]
Iwashita, Takuji [1 ,4 ]
Okuno, Mitsuru [1 ,5 ]
Mukai, Tsuyoshi [1 ,5 ,6 ]
Mabuchi, Masatoshi [1 ,7 ]
Adachi, Seiji [1 ,7 ]
Doi, Shinpei [1 ,8 ]
Imura, Johji [1 ,2 ]
Ozawa, Eisuke [1 ,3 ]
Miyaaki, Hisamitsu [1 ,3 ]
Nakao, Kazuhiko [1 ,3 ]
机构
[1] Univ Toyama, Dept Internal Med 3, 2630 Sugitani, Toyama 9300194, Japan
[2] Univ Toyama, Acad Assembly, Fac Med, Dept Diagnost Pathol, Toyama, Japan
[3] Nagasaki Univ, Grad Sch Biomed Sci, Dept Gastroenterol & Hepatol, Nagasaki, Japan
[4] Gifu Univ Hosp, Dept Internal Med 1, Gifu, Japan
[5] Gifu Municipal Hosp, Dept Gastroenterol, Gifu, Japan
[6] Kanazawa Med Univ, Dept Gastroenterol Endoscopy, Kanazawa, Ishikawa, Japan
[7] Gihoku Kousei Hosp, Dept Gastroenterol, Gifu, Japan
[8] Teikyo Univ, Mizonokuchi Hosp, Dept Gastroenterol, Kawasaki, Kanagawa, Japan
基金
日本学术振兴会;
关键词
ASPIRATION BIOPSY; ENDOSCOPIC ULTRASONOGRAPHY; TISSUE ACQUISITION; 19-GAUGE NEEDLE; PASSES; NUMBER; MASSES; TRIAL; ACTUATION; DIAGNOSIS;
D O I
10.1016/j.gie.2023.01.037
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: A novel EUS-guided fine-needle biopsy sampling (EUS-FNB) needle enabled physicians to obtain sufficient pathologic samples with fewer to-and-fro movements (TAFs) within the lesion. We compared the diagnostic yields of EUS-FNB with 3 and 12 TAFs at each puncture pass. Methods: The primary endpoint of this multicenter, noninferiority, crossover, randomized controlled trial involving 6 centers was diagnostic sensitivity. Secondary endpoints were diagnostic accuracy and quantity and quality evaluation of EUS-FNB specimens. Length of the macroscopically visible core (MVC) and microscopic histologic quantity were used for quantitative evaluation. Macroscopic visual and microscopic histologic evaluations were performed for qualitative evaluation. Results: Among 110 patients (220 punctures, 110 for 3 TAFs and 12 TAFs each), 105 (210 punctures) had malignant histology. Diagnostic sensitivity for malignancy of 3 TAFs (88.6%) was not inferior to that of 12 TAFs (89.5%; difference, -.9%; 95% confidence interval, -9.81 to 7.86). Diagnostic accuracy for malignancy was 92.7% for 3 TAFs and 94.6% for 12 TAFs. Overall median MVC length was 13.5 mm in both groups. The 3-TAF group had a significantly higher rate of score >3 on macroscopic visual quality evaluation than the 12-TAF group (71.8% vs 52.7%, P = .009). No significant intergroup differences existed in microscopic histologic quantity and quality evaluations (quantity evaluation, 88.2% for 3 TAFs vs 83.6% for 12 TAFs; quality evaluation, 90.0% for 3 TAFs vs 89.1% for 12 TAFs). Conclusions: Diagnostic sensitivity and accuracy of EUS-FNB with 3 TAFs were not inferior to those with 12 TAFs for solid pancreatic lesions. The 3-TAF group showed significantly less blood contamination in sampled tissues than the 12-TAF group.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 32 条
  • [1] A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy
    Aadam, A. Aziz
    Wani, Sachin
    Amick, Ashley
    Shah, Janak N.
    Bhat, Yasser M.
    Hamerski, Christopher M.
    Klapman, Jason B.
    Muthusamy, V. Raman
    Watson, Rabindra R.
    Rademaker, Alfred W.
    Keswani, Rajesh N.
    Keefer, Laurie
    Das, Ananya
    Komanduri, Srinadh
    [J]. ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (05) : E497 - E505
  • [2] Randomized trial comparing fanning with standard technique for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic mass lesions
    Bang, J. Y.
    Magee, S. H.
    Ramesh, J.
    Trevino, J. M.
    Varadarajulu, S.
    [J]. ENDOSCOPY, 2013, 45 (06) : 445 - 450
  • [3] Endoscopic ultrasonography-guided tissue acquisition: How to achieve excellence
    Bhatia, Vikram
    Varadarajulu, Shyam
    [J]. DIGESTIVE ENDOSCOPY, 2017, 29 (04) : 417 - 430
  • [4] Endoscopic ultrasound (EUS)-guided fine needle biopsy alone vs. EUS-guided fine needle aspiration with rapid onsite evaluation in pancreatic lesions: a multicenter randomized trial
    Chen, Yen-, I
    Chatterjee, Avijit
    Berger, Robert
    Kanber, Yonca
    Wyse, Jonathan
    Lam, Eric
    Gan, Ian
    Auger, Manon
    Kenshil, Sana
    Telford, Jennifer
    Donnellan, Fergal
    Quinlan, James
    Lutzak, Gregory
    Alshamsi, Fatma
    Parent, Josee
    Waschke, Kevin
    Alghamdi, Adel
    Barkun, Jeffrey
    Metrakos, Peter
    Chaudhury, Prosanto
    Martel, Myriam
    Dorreen, Alastair
    Candido, Kristen
    Miller, Corey
    Adam, Viviane
    Barkun, Alan
    Zogopoulos, George
    Wong, Clarence
    [J]. ENDOSCOPY, 2022, 54 (01) : 4 - 12
  • [5] Single-pass 1-needle actuation versus single-pass 3-needle actuation technique for EUS-guided liver biopsy sampling: a randomized prospective trial (with video)
    Ching-Companioni, Rafael A.
    Johal, Amitpal S.
    Confer, Bradley D.
    Forster, Erin
    Khara, Harshit S.
    Diehl, David L.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2021, 94 (03) : 551 - 558
  • [6] Image-Guided Breast Interventions: Biopsy and Beyond
    Dhamija, Ekta
    Singh, Rashmi
    Mishra, Seema
    Hari, Smriti
    [J]. INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (02) : 391 - 399
  • [7] Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies
    Erickson, RA
    Sayage-Rabie, L
    Beissner, RS
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (02) : 184 - 190
  • [8] Prostate biopsy quality and patient experience with the novel Forsvall biopsy needle - a randomized controlled non-inferiority trial
    Forsvall, Andreas
    Fisher, Jane
    Wagenius, Magnus
    Broman, Christian
    Korkocic, Dejan
    Bratt, Ola
    Linder, Adam
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY, 2021, 55 (03) : 235 - 241
  • [9] Per-Pass Performance Characteristics of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Malignant Solid Pancreatic Masses in a Large Multicenter Cohort
    Ge, Phillip S.
    Wani, Sachin
    Watson, Rabindra R.
    Sedarat, Alireza
    Kim, Stephen
    Marshall, Carrie
    Wilson, Robert H.
    Makker, Jitin
    Mohamadnejad, Mehdi
    Komanduri, Srinadh
    Muthusamy, V. Raman
    [J]. PANCREAS, 2018, 47 (03) : 296 - 301
  • [10] A 19-Gauge Histology Needle Versus a 19-Gauge Standard Needle in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Lesions: A Multicenter Randomized Comparison Study (GREATER Study)
    Iwashita, Takuji
    Nakai, Yousuke
    Mukai, Tsuyoshi
    Togawa, Osamu
    Matsubara, Saburo
    Hatano, Yuichiro
    Hara, Akira
    Tanaka, Mariko
    Shibahara, Junji
    Fukayama, Masashi
    Isayama, Hiroyuki
    Yasuda, Ichiro
    [J]. DIGESTIVE DISEASES AND SCIENCES, 2018, 63 (04) : 1043 - 1051