EUS-guided fine-needle biopsy sampling of solid pancreatic tumors with 3 versus 12 to-and-fro movements: a multicenter prospective randomized controlled study

被引:10
作者
Takahashi, Kosuke [1 ,3 ]
Yasuda, Ichiro [1 ]
Hayashi, Nobuhiko [1 ]
Iwashita, Takuji [1 ,4 ]
Okuno, Mitsuru [1 ,5 ]
Mukai, Tsuyoshi [1 ,5 ,6 ]
Mabuchi, Masatoshi [1 ,7 ]
Adachi, Seiji [1 ,7 ]
Doi, Shinpei [1 ,8 ]
Imura, Johji [1 ,2 ]
Ozawa, Eisuke [1 ,3 ]
Miyaaki, Hisamitsu [1 ,3 ]
Nakao, Kazuhiko [1 ,3 ]
机构
[1] Univ Toyama, Dept Internal Med 3, 2630 Sugitani, Toyama 9300194, Japan
[2] Univ Toyama, Acad Assembly, Fac Med, Dept Diagnost Pathol, Toyama, Japan
[3] Nagasaki Univ, Grad Sch Biomed Sci, Dept Gastroenterol & Hepatol, Nagasaki, Japan
[4] Gifu Univ Hosp, Dept Internal Med 1, Gifu, Japan
[5] Gifu Municipal Hosp, Dept Gastroenterol, Gifu, Japan
[6] Kanazawa Med Univ, Dept Gastroenterol Endoscopy, Kanazawa, Ishikawa, Japan
[7] Gihoku Kousei Hosp, Dept Gastroenterol, Gifu, Japan
[8] Teikyo Univ, Mizonokuchi Hosp, Dept Gastroenterol, Kawasaki, Kanagawa, Japan
关键词
ASPIRATION BIOPSY; ENDOSCOPIC ULTRASONOGRAPHY; TISSUE ACQUISITION; 19-GAUGE NEEDLE; PASSES; NUMBER; MASSES; TRIAL; ACTUATION; DIAGNOSIS;
D O I
10.1016/j.gie.2023.01.037
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: A novel EUS-guided fine-needle biopsy sampling (EUS-FNB) needle enabled physicians to obtain sufficient pathologic samples with fewer to-and-fro movements (TAFs) within the lesion. We compared the diagnostic yields of EUS-FNB with 3 and 12 TAFs at each puncture pass. Methods: The primary endpoint of this multicenter, noninferiority, crossover, randomized controlled trial involving 6 centers was diagnostic sensitivity. Secondary endpoints were diagnostic accuracy and quantity and quality evaluation of EUS-FNB specimens. Length of the macroscopically visible core (MVC) and microscopic histologic quantity were used for quantitative evaluation. Macroscopic visual and microscopic histologic evaluations were performed for qualitative evaluation. Results: Among 110 patients (220 punctures, 110 for 3 TAFs and 12 TAFs each), 105 (210 punctures) had malignant histology. Diagnostic sensitivity for malignancy of 3 TAFs (88.6%) was not inferior to that of 12 TAFs (89.5%; difference, -.9%; 95% confidence interval, -9.81 to 7.86). Diagnostic accuracy for malignancy was 92.7% for 3 TAFs and 94.6% for 12 TAFs. Overall median MVC length was 13.5 mm in both groups. The 3-TAF group had a significantly higher rate of score >3 on macroscopic visual quality evaluation than the 12-TAF group (71.8% vs 52.7%, P = .009). No significant intergroup differences existed in microscopic histologic quantity and quality evaluations (quantity evaluation, 88.2% for 3 TAFs vs 83.6% for 12 TAFs; quality evaluation, 90.0% for 3 TAFs vs 89.1% for 12 TAFs). Conclusions: Diagnostic sensitivity and accuracy of EUS-FNB with 3 TAFs were not inferior to those with 12 TAFs for solid pancreatic lesions. The 3-TAF group showed significantly less blood contamination in sampled tissues than the 12-TAF group.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 32 条
[1]   A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy [J].
Aadam, A. Aziz ;
Wani, Sachin ;
Amick, Ashley ;
Shah, Janak N. ;
Bhat, Yasser M. ;
Hamerski, Christopher M. ;
Klapman, Jason B. ;
Muthusamy, V. Raman ;
Watson, Rabindra R. ;
Rademaker, Alfred W. ;
Keswani, Rajesh N. ;
Keefer, Laurie ;
Das, Ananya ;
Komanduri, Srinadh .
ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (05) :E497-E505
[2]   Randomized trial comparing fanning with standard technique for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic mass lesions [J].
Bang, J. Y. ;
Magee, S. H. ;
Ramesh, J. ;
Trevino, J. M. ;
Varadarajulu, S. .
ENDOSCOPY, 2013, 45 (06) :445-450
[3]   Endoscopic ultrasonography-guided tissue acquisition: How to achieve excellence [J].
Bhatia, Vikram ;
Varadarajulu, Shyam .
DIGESTIVE ENDOSCOPY, 2017, 29 (04) :417-430
[4]   Endoscopic ultrasound (EUS)-guided fine needle biopsy alone vs. EUS-guided fine needle aspiration with rapid onsite evaluation in pancreatic lesions: a multicenter randomized trial [J].
Chen, Yen-, I ;
Chatterjee, Avijit ;
Berger, Robert ;
Kanber, Yonca ;
Wyse, Jonathan ;
Lam, Eric ;
Gan, Ian ;
Auger, Manon ;
Kenshil, Sana ;
Telford, Jennifer ;
Donnellan, Fergal ;
Quinlan, James ;
Lutzak, Gregory ;
Alshamsi, Fatma ;
Parent, Josee ;
Waschke, Kevin ;
Alghamdi, Adel ;
Barkun, Jeffrey ;
Metrakos, Peter ;
Chaudhury, Prosanto ;
Martel, Myriam ;
Dorreen, Alastair ;
Candido, Kristen ;
Miller, Corey ;
Adam, Viviane ;
Barkun, Alan ;
Zogopoulos, George ;
Wong, Clarence .
ENDOSCOPY, 2022, 54 (01) :4-12
[5]   Single-pass 1-needle actuation versus single-pass 3-needle actuation technique for EUS-guided liver biopsy sampling: a randomized prospective trial (with video) [J].
Ching-Companioni, Rafael A. ;
Johal, Amitpal S. ;
Confer, Bradley D. ;
Forster, Erin ;
Khara, Harshit S. ;
Diehl, David L. .
GASTROINTESTINAL ENDOSCOPY, 2021, 94 (03) :551-558
[6]   Image-Guided Breast Interventions: Biopsy and Beyond [J].
Dhamija, Ekta ;
Singh, Rashmi ;
Mishra, Seema ;
Hari, Smriti .
INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (02) :391-399
[7]   Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies [J].
Erickson, RA ;
Sayage-Rabie, L ;
Beissner, RS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (02) :184-190
[8]   Prostate biopsy quality and patient experience with the novel Forsvall biopsy needle - a randomized controlled non-inferiority trial [J].
Forsvall, Andreas ;
Fisher, Jane ;
Wagenius, Magnus ;
Broman, Christian ;
Korkocic, Dejan ;
Bratt, Ola ;
Linder, Adam .
SCANDINAVIAN JOURNAL OF UROLOGY, 2021, 55 (03) :235-241
[9]   Per-Pass Performance Characteristics of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Malignant Solid Pancreatic Masses in a Large Multicenter Cohort [J].
Ge, Phillip S. ;
Wani, Sachin ;
Watson, Rabindra R. ;
Sedarat, Alireza ;
Kim, Stephen ;
Marshall, Carrie ;
Wilson, Robert H. ;
Makker, Jitin ;
Mohamadnejad, Mehdi ;
Komanduri, Srinadh ;
Muthusamy, V. Raman .
PANCREAS, 2018, 47 (03) :296-301
[10]   A 19-Gauge Histology Needle Versus a 19-Gauge Standard Needle in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Lesions: A Multicenter Randomized Comparison Study (GREATER Study) [J].
Iwashita, Takuji ;
Nakai, Yousuke ;
Mukai, Tsuyoshi ;
Togawa, Osamu ;
Matsubara, Saburo ;
Hatano, Yuichiro ;
Hara, Akira ;
Tanaka, Mariko ;
Shibahara, Junji ;
Fukayama, Masashi ;
Isayama, Hiroyuki ;
Yasuda, Ichiro .
DIGESTIVE DISEASES AND SCIENCES, 2018, 63 (04) :1043-1051