Experimental investigation on the bond-slip behavior between TRC-confined concrete and rebars after exposure to elevated temperatures

被引:0
作者
Shen, Linghua [1 ,2 ]
Wang, Shuaifeng [1 ]
Zhao, Hui [1 ,4 ]
Cong, Xi [3 ]
机构
[1] Taiyuan Univ Technol, Coll Civil Engn, Taiyuan, Peoples R China
[2] Guangdong Prov Key Lab Modern Civil Engn Technol, Guangzhou, Peoples R China
[3] China Univ Min & Technol, State Key Lab Geomech & Deep Underground Engn, Xuzhou, Peoples R China
[4] Taiyuan Univ Technol, Coll Civil Engn, Taiyuan 030002, Peoples R China
基金
中国国家自然科学基金;
关键词
Textile reinforced concrete (TRC); pull-out tests; bond behavior; elevated temperatures; energy analysis; REINFORCED-CONCRETE; FLEXURAL BEHAVIOR; TEXTILE; CARBON; BEAMS; FRP; PERFORMANCE; COMPOSITES; CAPACITY; SYSTEMS;
D O I
10.1080/00405000.2023.2200066
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In this study, the bond-slip behavior between textile reinforced concrete (TRC)-confined concrete and rebars both at ambient temperature and after ISO 834 standard fire was investigated experimentally through pull-out tests. The failure modes, ultimate load, average ultimate bonding stress and energy consumption were obtained and discussed. Effects of rebar diameters (12 mm, 14 mm and 16 mm), bonding lengths (2.5d, 5d and 7.5d) and high-temperature exposure durations (30 min and 60 min) on the bonding behavior between TRC-confined concrete and rebars were examined emphatically. It was observed that the damage modes of specimens changed from pull-out failure at ambient temperature into splitting failure for both TRC-confined specimens and companion unconfined specimens exposed to high temperatures. The results obtained demonstrated that both the ultimate load and the average ultimate bonding stress can be significantly improved by the utilization of TRC jackets after 30 min exposure, and the increment of the average ultimate bonding stress can reach up to 90% as compared to those unconfined specimens. However, the enhancement of TRC jackets became unobvious after 60 min. Finally, based on test results and Prigogine's dissipative structure theory, the energy analysis of bond-slip curves was evaluated to verify the enhancement of TRC jackets quantitatively.
引用
收藏
页码:266 / 277
页数:12
相关论文
共 42 条
[1]   Effect of elevated temperature environments on the residual axial capacity of RC columns strengthened with different techniques [J].
Al-Salloum, Yousef A. ;
Almusallam, Tarek H. ;
Elsanadedy, Hussein M. ;
Iqbal, Rizwan A. .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 115 :345-361
[2]   EXPERIMENTAL ANALYSIS OF THE LOSS OF BOND BETWEEN REBARS AND CONCRETE EXPOSED TO HIGH TEMPERATURES [J].
Borja Varona, F. ;
Javier Baeza, F. ;
Ivorra, Salvador ;
Bru, David .
DYNA, 2015, 90 (01) :78-86
[3]  
Cao L., 2016, Experimental study on RC beams shear strengthened with carbon fiber textile reinforced geopolymer mortar
[4]  
[曹亮 Cao Liang], 2019, [工程力学, Engineering Mechanics], V36, P207
[5]   Concrete confinement with TRM versus FRP jackets at elevated temperatures [J].
Cerniauskas, G. ;
Tetta, Z. ;
Bournas, D. A. ;
Bisby, L. A. .
MATERIALS AND STRUCTURES, 2020, 53 (03)
[6]   Experimental analysis on bond between PBO-FRCM strengthening materials and concrete [J].
D'Ambrisi, Angelo ;
Feo, Luciano ;
Focacci, Francesco .
COMPOSITES PART B-ENGINEERING, 2013, 44 (01) :524-532
[7]   Bond Performance of Basalt Fiber-Reinforced Polymer Bars to Concrete [J].
El Refai, Ahmed ;
Ammar, Mohamed-Amine ;
Masmoudi, Radhouane .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (03)
[8]  
European Federation of National Associations Representing Concrete (EFNARC), 1996, EUR SPEC SPRAYED CON, P1
[9]  
GB 50152-2012, 2012, STANDARD TEST METHOD
[10]  
GB/T 3362-2005, 2005, 33622005 GBT CHIN ST