A Multicircle Planar Electrical Impedance Tomography Sensor for 3-D Miniature Imaging

被引:8
作者
Yang, Lu [1 ]
Wu, Hongtao [1 ]
Liu, Kai [1 ]
Chen, Bai [1 ]
Huang, Shan [2 ]
Yao, Jiafeng [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Peoples R China
[2] Soochow Univ, Affiliated Hosp 1, Dept Pathol, Suzhou 215000, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Electrical impedance tomography; Electrodes; Three-dimensional displays; Image reconstruction; Imaging; Image sensors; Electrical impedance tomography (EIT); image reconstruction; miniature EIT imaging; miniature EIT sensor; multicircle electrode configuration; RECONSTRUCTION ALGORITHMS; EIT; STROKE;
D O I
10.1109/JSEN.2023.3262266
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a multicircle planar electrical impedance tomography (EIT) sensor is proposed for three-dimensional (3-D) miniature imaging. There are two problems in 3-D miniature EIT imaging: 1) the spatial resolution is low since the number of electrodes is limited and 2) contact impedance influences image reconstruction quality severely. The proposed EIT sensor made by a printed circuit board (PCB) adopts a multicircle structure and tackles the two problems. Driven electrodes are distributed on the outermost two circles, while measurement electrodes are distributed on the innermost circle. Contact impedance is reduced since the area of driven electrodes could be larger than traditional ones by using the multicircle structure, and it is also owning to gold that is deposited on the surface of the electrodes. Moreover, a new driven-measurement pattern of the EIT sensor is proposed to improve the spatial resolution as well as image reconstruction quality. The proposed EIT sensor is verified by both simulation and experiment. The average image correlation coefficient (ICC) is as high as 0.8475 in simulation. Compared with the 16-electrode EIT sensor, ICC is improved by 39.16%. In the experiment, the average ICC of four standard objects is 0.8389. The proposed 3-D EIT sensor is good at miniature imaging.
引用
收藏
页码:9697 / 9706
页数:10
相关论文
共 42 条
[1]   GREIT: a unified approach to 2D linear EIT reconstruction of lung images [J].
Adler, Andy ;
Arnold, John H. ;
Bayford, Richard ;
Borsic, Andrea ;
Brown, Brian ;
Dixon, Paul ;
Faes, Theo J. C. ;
Frerichs, Inez ;
Gagnon, Herve ;
Gaerber, Yvo ;
Grychtol, Bartlomiej ;
Hahn, Guenter ;
Lionheart, William R. B. ;
Malik, Anjum ;
Patterson, Robert P. ;
Stocks, Janet ;
Tizzard, Andrew ;
Weiler, Norbert ;
Wolf, Gerhard K. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) :S35-S55
[2]  
Blum Lenore., 1998, Complexity and Real Computation, P217
[3]   Jacobian calculation for electrical impedance tomography based on the reciprocity principle [J].
Brandstätter, B .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (03) :1309-1312
[4]  
Brown B. H., 2003, Journal of Medical Engineering & Technology, V27, P97, DOI 10.1080/0309190021000059687
[5]   EIT-Inspired Microfluidic Cytometer for Single-Cell Dielectric Spectroscopy [J].
Caselli, Federica ;
Bisegna, Paolo ;
Maceri, Franco .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2010, 19 (05) :1029-1040
[6]   Electrical impedance tomography for sensing with integrated microelectrodes on a CMOS microchip [J].
Chai, K. T. C. ;
Davies, J. H. ;
Cumming, D. R. S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :97-101
[7]   Development of a Portable Electrical Impedance Tomography Device for Online Thrombus Detection in Extracorporeal-Circulation Equipment [J].
Chen, Huaijin ;
Yao, Jiafeng ;
Yang, Lu ;
Liu, Kai ;
Chen, Bai ;
Li, Jianping ;
Takei, Masahiro .
IEEE SENSORS JOURNAL, 2021, 21 (03) :3653-3659
[8]  
Chen Z, 2020, PROC IEEE INT INSTRU, P1
[9]   Real-time detection of pneumothorax using electrical impedance tomogyaphy [J].
Costa, Eduardo L. V. ;
Chaves, Caroline N. ;
Gomes, Susimeire ;
Beraldo, Marcelo A. ;
Volpe, Marcia S. ;
Tucci, Mauro R. ;
Schettino, Lvany A. L. ;
Bohm, Stephan H. ;
Carvalho, Carlos R. R. ;
Tanaka, Harki ;
Lima, Raul G. ;
Amato, Marcelo B. P. .
CRITICAL CARE MEDICINE, 2008, 36 (04) :1230-1238
[10]   Electrical impedance tomography [J].
Costa, Eduardo L. V. ;
Lima, Raul Gonzalez ;
Amato, Marcelo B. P. .
CURRENT OPINION IN CRITICAL CARE, 2009, 15 (01) :18-24