Impact of boron doping on microporous carbon for enhancing the electrochemical sensitivity of vitamin D3

被引:11
作者
Prakasam, Sampathkumar [1 ,2 ]
Anthonysamy, Esokkiya [1 ,2 ]
Krishnan, Giribabu [1 ,2 ]
Chinnathambi, Suresh [1 ,2 ]
机构
[1] CSIR, Cent Electrochem Res Inst, Electrod & Electrocatalysis Div, Karaikkudi 630003, Tamil Nadu, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
关键词
Vitamin D-3; Electrochemical sensor; B-doped microporous carbon; Amperometry; In-situ UV-Visible spectroscopy; DOPED CARBON; LIQUID-CHROMATOGRAPHY; MESOPOROUS CARBON; HIGH-PERFORMANCE; SENSOR; OXIDATION;
D O I
10.1016/j.matchemphys.2023.127353
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Vitamin D deficiency is becoming a severe burden worldwide, the rapid lifestyle changes are an important cause of that. As a result, rapid, cost-effective, and discriminating sensors for the determination of vitamin D are highly required. Herein, we report, a non-enzymatic sensitive electrochemical method for the determination of vitamin D-3 using boron-doped microporous carbon (BMC) as a sensing matrix. The Boron was systematically integrated into the microporous carbon (MC) matrix to increase the electrochemical property. Among the synthesized materials, the MC modified with 5 wt.% boron showed better sensor performance than the others. The kinetics and concentration studies indicate that the rate of electro oxidation on the surface of the modified electrode is significantly faster than that of the unmodified electrode. The scan rate effect and pH studies provide the number of electron transfers, transfer coefficient, and diffusion coefficient of vitamin D-3 which are 2, 0.52, and 18.49x10(-12) cm(2)s(-1), respectively. The electrolytic pH had a large impact on the oxidation potential, and its ac-tivity was significantly closer to that of the previously reported boron-doped diamond electrode. The BMC-5 modified electrode has a great linear range (0.5 mu M-42 mu M) and a low detection limit (1.45 mu M). Hence, from this study, it is concluded that the low-cost and stable BMC is an alternate matrix for the determination of vitamin D-3.
引用
收藏
页数:11
相关论文
共 52 条
[1]   Fabrication of handmade paper sensor based on silver-cobalt doped copolymer-ionic liquid composite for monitoring of vitamin D3 level in real samples [J].
Anusha, Tummala ;
Bhavani, Kalli Sai ;
Kumar, J. V. Shanmukha ;
Bonanni, Alessandra ;
Brahman, Pradeep Kumar .
MICROCHEMICAL JOURNAL, 2021, 161
[2]   Designing and fabrication of electrochemical nanosensor employing fullerene-C60 and bimetallic nanoparticles composite film for the detection of vitamin D3 in blood samples [J].
Anusha, Tummala ;
Bhavani, Kalli Sai ;
Kumar, J. V. Shanmukha ;
Brahman, Pradeep Kumar .
DIAMOND AND RELATED MATERIALS, 2020, 104
[3]   Association of vitamin D status with COVID-19 and its severity [J].
Bae, Jae Hyun ;
Choe, Hun Jee ;
Holick, Michael F. ;
Lim, Soo .
REVIEWS IN ENDOCRINE & METABOLIC DISORDERS, 2022, 23 (03) :579-599
[4]   Boron and Nitrogen Co-Doped Porous Carbons Synthesized from Polybenzoxazines for High-Performance Supercapacitors [J].
Bai, Lijun ;
Ge, Yanping ;
Bai, Lizhong .
COATINGS, 2019, 9 (10)
[5]   High-Performance, Nitrogen-Doped, Carbon-Nanotube-Based Electrochemical Sensor For Vitamin D3 Detection [J].
Bora, Hema ;
Mandal, Debabrata ;
Chandra, Amreesh .
ACS APPLIED BIO MATERIALS, 2022, 5 (04) :1721-1730
[6]   HPLC determination of Vitamin D3 and its metabolite in human plasma with on-line sample cleanup [J].
Brunetto, MR ;
Obando, MA ;
Gallignani, M ;
Alarcón, OM ;
Nieto, E ;
Salinas, R ;
Burguera, JL ;
Burguera, M .
TALANTA, 2004, 64 (05) :1364-1370
[7]   Boron-doped carbon powders formed at 1000 °C and one atmosphere [J].
Burgess, James S. ;
Acharya, Chethan K. ;
Lizarazo, Jair ;
Yancey, Nathan ;
Flowers, Brian ;
Kwon, Gihan ;
Klein, Tonya ;
Weaver, Mark ;
Lane, Alan M. ;
Turner, C. Heath ;
Street, Shane .
CARBON, 2008, 46 (13) :1711-1717
[8]   Synthesis and characterization of α-nickel (II) hydroxide particles on organic-inorganic matrix and its application in a sensitive electrochemical sensor for vitamin D determination [J].
Canevari, Thiago C. ;
Cincotto, Fernando H. ;
Landers, Richard ;
Machado, Sergio A. S. .
ELECTROCHIMICA ACTA, 2014, 147 :688-695
[9]   Boron and nitrogen co-doped ordered microporous carbons with high surface areas [J].
Castro-Muniz, Alberto ;
Nishihara, Hirotomo ;
Hirota, Tetsuya ;
Ohwada, Mao ;
Li, Li-Xiang ;
Tsuda, Tetsuya ;
Kuwabata, Susumu ;
Maruyama, Jun ;
Kyotani, Takashi .
CHEMICAL COMMUNICATIONS, 2017, 53 (100) :13348-13351
[10]   Carbon cloth-based immunosensor for detection of 25-hydroxy vitamin D3 [J].
Chauhan, Deepika ;
Yadav, Amit K. ;
Solanki, Pratima R. .
MICROCHIMICA ACTA, 2021, 188 (04)