An image-based metal artifact reduction technique utilizing forward projection in computed tomography

被引:0
|
作者
Ichikawa, Katsuhiro [1 ]
Kawashima, Hiroki [1 ]
Takata, Tadanori [2 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Diagnost Radiol, 13-1 Takara Machi, Kanazawa 9208641, Japan
关键词
Computed tomography; Metal artifact; Forward projection; Projection data; Parallel computation; RECONSTRUCTION;
D O I
10.1007/s12194-024-00790-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The projection data generated via the forward projection of a computed tomography (CT) image (FP-data) have useful potentials in cases where only image data are available. However, there is a question of whether the FP-data generated from an image severely corrupted by metal artifacts can be used for the metal artifact reduction (MAR). The aim of this study was to investigate the feasibility of a MAR technique using FP-data by comparing its performance with that of a conventional robust MAR using projection data normalization (NMARconv). The NMAR(conv) was modified to make use of FP-data (FPNMAR). A graphics processing unit was used to reduce the time required to generate FP-data and subsequent processes. The performances of FPNMAR and NMAR(conv) were quantitatively compared using a normalized artifact index (AI(n)) for two cases each of hip prosthesis and dental fillings. Several clinical CT images with metal artifacts were processed by FPNMAR. The AI(n) values of FPNMAR and NMAR(conv) were not significantly different from each other, showing almost the same performance between these two techniques. For all the clinical cases tested, FPNMAR significantly reduced the metal artifacts; thereby, the images of the soft tissues and bones obscured by the artifacts were notably recovered. The computation time per image was similar to 56 ms. FPNMAR, which can be applied to CT images without accessing the projection data, exhibited almost the same performance as that of NMAR(conv), while consuming significantly shorter processing time. This capability testifies the potential of FPNMAR for wider use in clinical settings.
引用
收藏
页码:402 / 411
页数:10
相关论文
共 50 条
  • [21] Metal artifact reduction in computed tomography using local models in an image block-iterative scheme
    Van Slambrouck, Katrien
    Nuyts, Johan
    MEDICAL PHYSICS, 2012, 39 (11) : 7080 - 7093
  • [22] High Quality X-Ray Imaging Based on Cumulation of Forward Projection of Computed Tomography
    Yang, Fuqiang
    Zhang, Dinghua
    Zhang, Hua
    Huang, Kuidong
    Teng, Mingxuan
    Du, You
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [23] Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
    Watanabe, Shota
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Kono, Yuki
    Kosaka, Hiroyuki
    Yamada, Koji
    Ishii, Kazunari
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 100 - 108
  • [24] A methodical assessment of interpolation techniques to metal artifact reduction in Computed Tomography
    Souza Paulino, Jose Alberto
    de Sousa, Robson Pequeno
    Dantas de Almeida, Carlos Wilson
    Valadares Oliveira, Eduardo Jorge
    Galdino, Katia Elizabete
    de Morals, Misael Elias
    2019 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2019, : 2428 - 2432
  • [25] Metal Artifact Reduction in Computed Tomography Using Nonequispaced Fourier Transform
    Kratz, Baerbel
    Buzug, Thorsten M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2720 - 2723
  • [26] Customized Total Variation Algorithm for Metal Artifact Reduction in Computed Tomography
    Deng, Ziheng
    Zhou, Yufu
    Zhang, Weikang
    Lin, Zefan
    Zhao, Jun
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3479 - 3482
  • [27] Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
    Zhang, Yanbo
    Yu, Hengyong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (06) : 1370 - 1381
  • [28] The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review
    Puvanasunthararajah, Sathyathas
    Fontanarosa, Davide
    Wille, Marie-Luise
    Camps, Saskia M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 198 - 223
  • [29] High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography
    Xi, Yan
    Jin, Yannan
    De Man, Bruno
    Wang, Ge
    IEEE ACCESS, 2016, 4 : 4769 - 4776
  • [30] Developments of Metal Artifact Reduction Methods for Cone-beam Computed Tomography
    Shih, Kun-Long
    David
    Jin, Shih-Chun
    Chen, Jyh-Cheng
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214