Technical note: Simulation of lung counting applications using Geant4

被引:1
|
作者
Jutila, Henri [1 ,2 ]
Greenlees, Paul [1 ,2 ]
Torvela, Tiina [3 ]
Muikku, Maarit [3 ]
机构
[1] Univ Jyvaskyla, Dept Phys, Accelerator Lab, FI-40014 Jyvaskyla, Finland
[2] Univ Helsinki, Helsinki Inst Phys, POB 64, FI-00014 Helsinki, Finland
[3] STUK Radiat & Nucl Safety Author, Jokiniemenkuja 1, Vantaa 01370, Finland
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 108卷
关键词
Lung counting; Voxel phantom; Geant4; simulation; Low-energy gamma-ray spectra;
D O I
10.1016/j.ejmp.2023.102573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a function of photon energy. The transmission of 59.5 keV gamma rays, characteristic of the decay of 241Am, was determined from the computational phantom as a function of the angular position of the detector. It was found that the simulated detector response corresponds well with that from an experiment. The simulated count rate below 100 keV was 10.0(7) % greater compared to the experimental measurement. It was observed that 58.3(4) % of photons are attenuated for energies below 100 keV by the chest wall. In the simulation, the transmission of 59.5 keV gamma rays varied from 13.8(2) % to 38.0(4) % as a function of the angular position of the detector. The results obtained from the simulations show a satisfactory agreement with experimental data and the package can be used in the development of future body counting applications and enables optimization of the detection geometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Application of GEANT4 to the Simulation of High Energy-Resolution Microcalorimeter Detectors
    Hoover, Andrew S.
    Bacrania, Minesh K.
    Karpius, Pete J.
    Rabin, Michael W.
    Rudy, Cliff R.
    Vo, Duc T.
    Beall, James A.
    Doriese, William B.
    Hilton, Gene C.
    Horansky, Robert D.
    Irwin, Kent D.
    Ullom, Joel N.
    Vale, Leila R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) : 2294 - 2298
  • [42] A Geant4 simulation for three-dimensional proton imaging of microscopic samples
    Michelet, Claire
    Li, Zhuxin
    Yang, Wen
    Incerti, Sebastien
    Desbarats, Pascal
    Giovannelli, Jean-Francois
    Barberet, Philippe
    Delville, Marie-Helene
    Gordillo, Nuria
    Deves, Guillaume
    Seznec, Herve
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 172 - 180
  • [43] Analysis of Geant4 simulations of proton depth dose profiles for radiotherapy applications
    Lechner, Anton
    Pia, Maria Grazia
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 147 - +
  • [44] MODELING ALPHA PARTICLE-INDUCED RADIOLUMINESCENCE USING GEANT4
    Olaru, C.
    Ioan, M. -R.
    Zadehrafi, M.
    ROMANIAN JOURNAL OF PHYSICS, 2023, 68 (9-10):
  • [45] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Chen, Jun-Liang
    Yun, Su-Jun
    Dong, Tie-Kuang
    Ren, Zhong-Zhou
    Zhang, Xiao-Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (01)
  • [46] Gamma-Ray Attenuation and Exposure Buildup Factor of Novel Polymers in Shielding Using Geant4 Simulation
    Alabsy, Mahmoud T.
    Alzahrani, Jamila S.
    Sayyed, M., I
    Abbas, Mahmoud, I
    Tishkevich, Daria, I
    El-Khatib, Ahmed M.
    Elsafi, Mohamed
    MATERIALS, 2021, 14 (17)
  • [47] Detailed optimization procedure of an HPGe detector using Geant4 toolkit
    Travar, M.
    Nikolov, J.
    Todorovic, N.
    Vranicar, A.
    Volgyesi, P.
    Kirchknopf, P.
    Celikovic, I.
    Milanovic, T.
    Jokovic, D.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (03) : 817 - 828
  • [48] Exploring green environmental composites as hosts for shielding materials using experimental, theoretical and Geant4 simulation methods
    Alabsy, Mahmoud T.
    Abbas, Mahmoud I.
    Sharaby, Mahmoud A.
    Abd Elzaher, Mohamed
    Doma, A. S.
    El-Khatib, Ahmed M.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [49] Geant4 software application for the simulation of cosmic ray showers in the Earth's atmosphere
    Paschalis, P.
    Mavromichalaki, H.
    Dorman, L. I.
    Plainaki, C.
    Tsirigkas, D.
    NEW ASTRONOMY, 2014, 33 : 26 - 37
  • [50] GEANT4 Simulation of the High-Energy Neutron Beam of the TOF Spectrometer GNEIS
    A. V. Nakin
    A. S. Vorobyev
    O. A. Shcherbakov
    Physics of Atomic Nuclei, 2019, 82 : 1661 - 1664