Technical note: Simulation of lung counting applications using Geant4

被引:1
|
作者
Jutila, Henri [1 ,2 ]
Greenlees, Paul [1 ,2 ]
Torvela, Tiina [3 ]
Muikku, Maarit [3 ]
机构
[1] Univ Jyvaskyla, Dept Phys, Accelerator Lab, FI-40014 Jyvaskyla, Finland
[2] Univ Helsinki, Helsinki Inst Phys, POB 64, FI-00014 Helsinki, Finland
[3] STUK Radiat & Nucl Safety Author, Jokiniemenkuja 1, Vantaa 01370, Finland
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 108卷
关键词
Lung counting; Voxel phantom; Geant4; simulation; Low-energy gamma-ray spectra;
D O I
10.1016/j.ejmp.2023.102573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a function of photon energy. The transmission of 59.5 keV gamma rays, characteristic of the decay of 241Am, was determined from the computational phantom as a function of the angular position of the detector. It was found that the simulated detector response corresponds well with that from an experiment. The simulated count rate below 100 keV was 10.0(7) % greater compared to the experimental measurement. It was observed that 58.3(4) % of photons are attenuated for energies below 100 keV by the chest wall. In the simulation, the transmission of 59.5 keV gamma rays varied from 13.8(2) % to 38.0(4) % as a function of the angular position of the detector. The results obtained from the simulations show a satisfactory agreement with experimental data and the package can be used in the development of future body counting applications and enables optimization of the detection geometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Investigation of SPECT/CT cardiac imaging using Geant4
    A.Alfuraih
    O.Kadri
    K.Alzimami
    NuclearScienceandTechniques, 2018, 29 (07) : 47 - 57
  • [32] Calculating the Indoor Dose Deposited by γ-Photons Using GEANT4
    Argintaru, Danut
    Baban, Valerica
    Constantinescu, Eliodor
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES V, 2010, 7821
  • [33] Investigation of SPECT/CT cardiac imaging using Geant4
    A. Alfuraih
    O. Kadri
    K. Alzimami
    Nuclear Science and Techniques, 2018, 29
  • [34] Computation and parameterization of normalized glandular dose using Geant4
    Kadri, Omrane
    Alnafea, Mohammed Ali
    Shamma, Khaled
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (03)
  • [35] Investigation of SPECT/CT cardiac imaging using Geant4
    Alfuraih, A.
    Kadri, O.
    Alzimami, K.
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (07)
  • [36] A novel embedded spherical semiconductor neutron detector efficiency estimation using GEANT4 simulation methodology
    Nayak, Avinash
    Kumar, Vikas
    Parida, Manoj Kumar
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (03)
  • [37] Investigation of cosmic-ray induced background of Germanium gamma spectrometer using GEANT4 simulation
    Nguyen Quoc Hung
    Vo Hong Hai
    Nomachi, Masaharu
    APPLIED RADIATION AND ISOTOPES, 2017, 121 : 87 - 90
  • [38] Experimental spectra analysis in THM with the help of simulation based on the Geant4 framework
    Li Cheng-Bo
    Wen Qun-Gang
    Zhou Shu-Hua
    Jiang Zong-Jun
    Fu Yuan-Yong
    Zhou Jing
    Meng Qiu-Ying
    Wang Xiao-Lian
    CHINESE PHYSICS C, 2015, 39 (05)
  • [39] Evaluation of space radiation effects on FinFET oxide layer with Geant4 simulation
    Zhang, Jianyu
    Hua, Yang
    Huang, Sichong
    Li, Tongde
    Wang, Liang
    Zhang, Xing
    Zhao, Yuanfu
    MICROELECTRONICS JOURNAL, 2025, 156
  • [40] GEANT4 simulation of a range verification method using delayed γ spectroscopy of a 92Mo marker
    Kasanda, E.
    Burbadge, C.
    Bildstein, V
    Turko, J.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24)