Cost-effectiveness of 82-Rubidium PET myocardial perfusion imaging for the diagnosis of myocardial ischemia depending on the prevalence of coronary artery disease

被引:8
作者
Mimouni, Maroua [1 ]
Bulsei, Julie [1 ]
Darlington, Meryl [1 ]
Estellat, Candice [2 ,3 ]
Rouzet, Francois [4 ,5 ,6 ]
Hyafil, Fabien [7 ,8 ]
Durand-Zaleski, Isabelle [1 ,9 ,10 ,11 ]
机构
[1] Assistance Publ Hop Paris AP HP, DRCI URC Eco Ile De France, Paris, France
[2] Hop La Pitie Salpetriere, AP HP, Dept Biostat, Sante Publ & Informat Medicale, F-75013 Paris, France
[3] INSERM, CIC EC 1425, ECEVE UMR 1123, F-75018 Paris, France
[4] Dept Nucl Med, Bichat Hosp, AP HP, F-75018 Paris, France
[5] INSERM, U 1148, Paris, France
[6] Univ Paris, F-75018 Paris, France
[7] Univ Paris, Georges Pompidou European Hosp, AP HP, Dept Nucl Med,DMU IMAGINA, F-75015 Paris, France
[8] Univ Paris, U 970, INSERM, F-75015 Paris, France
[9] Henri Mondor Albert Chenevier, Assistance Publ Hop Paris, Serv Sante Publ, Creteil, France
[10] INSERM, UMR 1153 CRESS, Paris, France
[11] UPEC, Creteil, France
关键词
Cost-effectiveness; 82-Rubidium PET; SPECT; Myocardial perfusion imaging; Obstructive coronary artery disease; RB-82; TOMOGRAPHY; ACCURACY;
D O I
10.1186/s13550-023-00954-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background 82-Rubidium-Positron emission tomography myocardial perfusion imaging (Rb-PET-MPI) offers higher diagnostic performance for the detection of myocardial ischemia compared to Tc-SPECT-MPI. The aim of this economic evaluation was to perform a cost-effectiveness analysis of Rb-PET-MPI versus Tc-SPECT-MPI in patients with suspected myocardial ischemia according to pretest probabilities (PTP) of obstructive coronary artery disease based on the results of the RUBIS Trial.Methods Costs and effectiveness were calculated for all patients over 1 year and an incremental analysis of differences in costs and effectiveness in terms of diagnostic accuracy was performed. The uncertainty of the results was estimated using bootstrap. The analysis was conducted from the perspective of the French health care system with a time horizon of 12 months.Results The average cost of a Rb-PET-MPI-based strategy for the detection of myocardial ischemia was euro219 lower than a SPECT-MPI-based strategy (euro1192 (& PLUSMN; 1834) vs euro973 (+/- 1939), p < 0.01). The one-year incremental cost-effectiveness ratio was negative: - euro2730 (money saved per additional accurate diagnosis) in patients presenting PTP > 15% for the Rb-PET-MPI vs. Tc-SPECT-MPI strategy. Analysis of the joint distribution of costs and outcomes found that the Rb-PET-MPI strategy had a 92% probability to be dominant (cost-saving and outcome-improving).Conclusions Rb-PET-MPI is cost-effective compared to Tc-SPECT-MPI for the detection of myocardial ischemia in patients with PTP > 15% of obstructive coronary artery disease.
引用
收藏
页数:9
相关论文
共 18 条
[1]   Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging [J].
Acampa, Wanda ;
Zampella, Emilia ;
Assante, Roberta ;
Genova, Andrea ;
De Simini, Giovanni ;
Mannarino, Teresa ;
D'Antonio, Adriana ;
Gaudieri, Valeria ;
Nappi, Carmela ;
Buongiorno, Pietro ;
Mainolfi, Ciro Gabriele ;
Petretta, Mario ;
Cuocolo, Alberto .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) :2827-2839
[2]   First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study [J].
Agostini, Denis ;
Roule, Vincent ;
Nganoa, Catherine ;
Roth, Nathaniel ;
Baavour, Raphael ;
Parienti, Jean-Jacques ;
Beygui, Farzin ;
Manrique, Alain .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (07) :1079-1090
[3]  
[Anonymous], Choix methodologiques pour l'evaluation economique a la HAS
[4]  
Calizzano Alex, 2007, Medecine Nucleaire, V31, P604, DOI 10.1016/j.mednuc.2007.08.001
[5]   Story of rubidium-82 and advantages for myocardial perfusion PET imaging [J].
Chatal, Jean-Francois ;
Rouzet, Francois ;
Haddad, Fend ;
Bourdeau, Cecile ;
Mathieu, Cedric ;
Le Guludec, Dominique .
FRONTIERS IN MEDICINE, 2015, 2
[6]   Cost-effectiveness of alternative test strategies for the diagnosis of coronary artery disease [J].
Garber, AM ;
Solomon, NA .
ANNALS OF INTERNAL MEDICINE, 1999, 130 (09) :719-+
[7]   Review: comparison of PET rubidium-82 with conventional SPECT myocardial perfusion imaging [J].
Ghotbi, Adam A. ;
Kjaer, Andreas ;
Hasbak, Philip .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (03) :163-170
[8]   Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity [J].
Harnett, David T. ;
Hazra, Samir ;
Maze, Ronnen ;
Mc Ardle, Brian A. ;
Alenazy, Ali ;
Simard, Trevor ;
Henry, Ellen ;
Dwivedi, Girish ;
Glover, Christopher ;
deKemp, Robert A. ;
Davies, Ross A. ;
Ruddy, Terrence D. ;
Chow, Benjamin J. W. ;
Beanlands, Rob S. ;
Hibbert, Benjamin .
JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) :275-283
[9]   Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging [J].
Hunter, Chad R. R. N. ;
Hill, Jeremy ;
Ziadi, M. Cecilia ;
Beanlands, Rob S. B. ;
deKemp, Robert A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (07) :1032-1042
[10]   Consolidated Health Economic Evaluation Reporting Standards (CHEERS)-Explanation and Elaboration: A Report of the ISPOR Health Economic Evaluation Publication Guidelines Good Reporting Practices Task Force [J].
Husereau, Don ;
Drummond, Michael ;
Petrou, Stavros ;
Carswell, Chris ;
Moher, David ;
Greenberg, Dan ;
Augustovski, Federico ;
Briggs, Andrew H. ;
Mauskopf, Josephine ;
Loder, Elizabeth .
VALUE IN HEALTH, 2013, 16 (02) :231-250