Wind-Induced Response Analysis of the Transmission Tower-Line System Considering the Joint Effect

被引:4
作者
Li, Jia-Xiang [1 ,2 ]
Zhang, Chao [1 ]
Fu, Xing [2 ]
机构
[1] Northeastern Univ, Sch Resources & Civil Engn, Shenyang 110819, Liaoning, Peoples R China
[2] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Liaoning, Peoples R China
关键词
Transmission tower-line system; wind load; joint effect; wind-induced response; numerical simulation; BOLTED JOINTS; MODEL; PERFORMANCE; SLIPPAGE; COLLAPSE; RAIN;
D O I
10.1142/S0219455424502523
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind load is one of the main control loads of transmission tower-line systems. Numerical simulation is the main method for studying the structural wind-induced response. The establishment of a refined transmission tower simulation model is the basis for accurately analyzing the dynamic response of a transmission tower-line system under a wind load. This paper first considered the mechanical properties of bolted joints under cyclic loading and established a transmission tower-line system model considering the joint effects. Then, the wind load was generated by the harmonic superposition method, and the wind dynamic time-history analysis of the tower-line system was conducted. The influence of the joint effect on the wind-induced response of the transmission tower-line system was studied, and the effects of turbulence intensity and wind attack angle on the bolted joint slip effect were discussed. The results showed that the joint effect significantly increased the displacement response of the transmission tower subjected to wind loads and affected the normal service performance of the tower-line system. When the turbulence intensity is 10%, the top displacement of the tower model considering the joint effect is approximately 2 times that of the ideal rigid frame model. After considering the joint effect, the additional P - Delta effect caused by the increased displacement resulted in an increase in the stress of 75.6% members, and the maximum stress of the main member was located near the upper diaphragm of the tower leg. Therefore, considering the joint slip effect in angle steel transmission towers can improve the accuracy of the dynamic response analysis of transmission lines.
引用
收藏
页数:23
相关论文
共 44 条
[1]   Influence of Bolted-Joint Slippage on the Response of Transmission Towers Subjected to Frost-Heave [J].
Ahmed, K. I. E. ;
Rajapakse, R. K. N. D. ;
Gadala, M. S. .
ADVANCES IN STRUCTURAL ENGINEERING, 2009, 12 (01) :1-17
[2]   Experimental and numerical study of the axial stiffness of bolted joints in steel lattice transmission tower legs [J].
An, Liqiang ;
Wu, Jiong ;
Jiang, Wenqiang .
ENGINEERING STRUCTURES, 2019, 187 :490-503
[3]   Failure analysis of a lattice transmission tower collapse due to the super typhoon Rammasun in July 2014 in Hainan Province, China [J].
An, Liqiang ;
Wu, Jiong ;
Zhang, Zhiqiang ;
Zhang, Ronglun .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 182 :295-307
[4]  
[Anonymous], 2012, DLT 5154-2012
[5]  
[Anonymous], 2012, GB 50009-2012
[6]  
[Anonymous], 2018, DL/T 5551-2018
[7]   Simplified bolted connection model for analysis of transmission line towers [J].
Balagopal, R. ;
Ramaswamy, Ananth ;
Palani, G. S. ;
Rao, N. Prasad .
STRUCTURES, 2020, 27 :2114-2125
[8]   Probabilistic serviceability-performance assessment of tall mass-timber buildings subjected to stochastic wind loads: Part II - structural reliability analysis [J].
Bezabeh, M. A. ;
Bitsuamlak, G. T. ;
Popovski, M. ;
Tesfamariam, S. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 181 :112-125
[9]   Fragility modelling framework for transmission line towers under winds [J].
Cai, Yunzhu ;
Xie, Qiang ;
Xue, Songtao ;
Hu, Liang ;
Kareem, Ahsan .
ENGINEERING STRUCTURES, 2019, 191 :686-697
[10]   Effect of modelling complexities on extreme wind hazard performance of steel lattice transmission towers [J].
Darestani, Yousef Mohammadi ;
Shafieezadeh, Abdollah ;
Cha, Kyunghwa .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (06) :898-915