Comprehensive two-dimensional gas chromatography under low-pressure conditions

被引:1
作者
Corbally, Michelle A. [1 ]
Hinz, Nicholas S. [2 ]
Freye, Chris E. [1 ]
机构
[1] Los Alamos Natl Lab, High Explos Sci & Technol, Q-5, Los Alamos, NM 87545 USA
[2] US Naval Acad, 121 Blake Rd, Annapolis, MD USA
关键词
Comprehensive two-dimensional gas; chromatography (GC x GC); Low-pressure GC; Mass Spectrometry; Thermally labile; TANDEM MASS-SPECTROMETRY; MULTIPLE PESTICIDE-RESIDUES; HIGH-THROUGHPUT ANALYSIS; CAPILLARY GC; TIME; QUECHERS; FOOD; MODULATION; INSTRUMENTATION; TEMPERATURE;
D O I
10.1016/j.chroma.2023.464203
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC x GC), allows for resolution of compounds that would typically coelute using GC. In this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC x GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC x GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 & DEG;C less on the lowpressure GC x GC-TOFMS configuration compared to the conventional GC x GC-TOFMS configuration. Moreover, the compounds were separated in-13 min on the low-pressure GC x GC-TOFMS as opposed to 33 min for conventional GC x GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC x GC-TOFMS had a lower, & beta; corrected 2D peak capacity, nc,& beta;,2D, of 1260 while the conventional GC x GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC x GC-TOFMS, respectively. A "real world" sample of diesel fuel was tested on the low-pressure and conventional GC x GCTOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC x GC-TOFMS configuration was higher than that of the conventional GC x GC-TOFMS method.& COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
[41]   Interpretation of comprehensive two-dimensional gas chromatography data using advanced chemometrics [J].
Zeng, Zhongda ;
Li, Jia ;
Hugel, Helmut M. ;
Xu, Guowang ;
Marriott, Philip J. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 53 :150-166
[42]   Forensic profiling of sassafras oils based on comprehensive two-dimensional gas chromatography [J].
Schaeffer, M. ;
Groeger, T. ;
Puetz, M. ;
Zimmermann, R. .
FORENSIC SCIENCE INTERNATIONAL, 2013, 229 (1-3) :108-115
[43]   Impact of comprehensive two-dimensional gas chromatography with mass spectrometry on food analysis [J].
Tranchida, Peter Q. ;
Purcaro, Giorgia ;
Maimone, Mariarosa ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2016, 39 (01) :149-161
[44]   Predictions of comprehensive two-dimensional gas chromatography separations from isothermal data [J].
Zhu, Shukui ;
He, Sheng ;
Worton, David R. ;
Goldstein, Allen H. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 :147-151
[45]   Analysis of siloxanes in hydrocarbon mixtures using comprehensive two-dimensional gas chromatography [J].
Ghosh, Abhijit ;
Seeley, Stacy K. ;
Nartker, Steven R. ;
Seeley, John V. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 :258-263
[46]   Frontier review on comprehensive two-dimensional gas chromatography for measuring organic aerosol [J].
An, Zhaojin ;
Li, Xue ;
Shi, Zongbo ;
Williams, Brent J. ;
Harrison, Roy M. ;
Jiang, Jingkun .
JOURNAL OF HAZARDOUS MATERIALS LETTERS, 2021, 2
[47]   Comprehensive two-dimensional gas chromatography for the analysis of organohalogenated micro-contaminants [J].
Korytár, P ;
Haglund, P ;
de Boer, J ;
Brinkman, UAT .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (04) :373-396
[48]   Enantiomeric Separation in Comprehensive Two-dimensional Gas Chromatography with Accurate Mass Analysis [J].
Chin, Sung-Tong ;
Nolvachai, Yada ;
Marriott, Philip J. .
CHIRALITY, 2014, 26 (11) :747-753
[49]   The Modulator in Comprehensive Two-Dimensional Liquid Chromatography [J].
Egeness, Mari J. ;
Breadmore, Michael C. ;
Hilder, Emily F. ;
Shellie, Robert A. .
LC GC EUROPE, 2016, 29 (05) :268-276
[50]   Complementarity of two-dimensional gas chromatography and two-dimensional liquid chromatography for the analysis of depolymerised lignin [J].
Tammekivi, Eliise ;
Lilti, Hugo ;
Batteau, Magali ;
Lorentz, Chantal ;
Geantet, Christophe ;
Laurenti, Dorothee ;
Faure, Karine .
JOURNAL OF CHROMATOGRAPHY A, 2024, 1736