Comprehensive two-dimensional gas chromatography under low-pressure conditions

被引:1
|
作者
Corbally, Michelle A. [1 ]
Hinz, Nicholas S. [2 ]
Freye, Chris E. [1 ]
机构
[1] Los Alamos Natl Lab, High Explos Sci & Technol, Q-5, Los Alamos, NM 87545 USA
[2] US Naval Acad, 121 Blake Rd, Annapolis, MD USA
关键词
Comprehensive two-dimensional gas; chromatography (GC x GC); Low-pressure GC; Mass Spectrometry; Thermally labile; TANDEM MASS-SPECTROMETRY; MULTIPLE PESTICIDE-RESIDUES; HIGH-THROUGHPUT ANALYSIS; CAPILLARY GC; TIME; QUECHERS; FOOD; MODULATION; INSTRUMENTATION; TEMPERATURE;
D O I
10.1016/j.chroma.2023.464203
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC x GC), allows for resolution of compounds that would typically coelute using GC. In this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC x GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC x GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 & DEG;C less on the lowpressure GC x GC-TOFMS configuration compared to the conventional GC x GC-TOFMS configuration. Moreover, the compounds were separated in-13 min on the low-pressure GC x GC-TOFMS as opposed to 33 min for conventional GC x GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC x GC-TOFMS had a lower, & beta; corrected 2D peak capacity, nc,& beta;,2D, of 1260 while the conventional GC x GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC x GC-TOFMS, respectively. A "real world" sample of diesel fuel was tested on the low-pressure and conventional GC x GCTOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC x GC-TOFMS configuration was higher than that of the conventional GC x GC-TOFMS method.& COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography
    Blumberg, Leonid M.
    David, Frank
    Klee, Matthew S.
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) : 2 - 16
  • [22] Comprehensive two-dimensional gas chromatography-mass spectrometry using milder electron ionization conditions: A preliminary evaluation
    Tranchida, Peter Q.
    Aloisi, Ivan
    Giocastro, Barbara
    Zoccali, Mariosimone
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1589 : 134 - 140
  • [23] Dynamic pressure gradient modulation for comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detection
    Schoneich, Sonia
    Gough, Derrick, V
    Trinklein, Timothy J.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1620
  • [24] Chemical signature of ecstasy volatiles by comprehensive two-dimensional gas chromatography
    Mitrevski, Blagoj
    Veleska, Biljana
    Engel, Erwan
    Wynne, Paul
    Song, Shin Miin
    Marriott, Philip J.
    FORENSIC SCIENCE INTERNATIONAL, 2011, 209 (1-3) : 11 - 20
  • [25] The role of comprehensive two-dimensional gas chromatography in mineral oil determination
    Bauwens, Gregory
    Gorska, Aleksandra
    Purcaro, Giorgia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (21) : 5067 - 5082
  • [26] Comprehensive two-dimensional gas chromatography-A discussion on recent innovations
    Milani, Nino B. L.
    van Gilst, Eric
    Pirok, Bob W. J.
    Schoenmakers, Peter J.
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (21)
  • [27] Separation and identification of petroleum biomarkers by comprehensive two-dimensional gas chromatography
    Frysinger, GS
    Gaines, RB
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (02) : 87 - 96
  • [28] A New Dimension in Separation Science: Comprehensive Two-Dimensional Gas Chromatography
    Meinert, Cornelia
    Meierhenrich, Uwe J.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (42) : 10460 - 10470
  • [29] Retention modelling of polychlorinated biphenyls in comprehensive two-dimensional gas chromatography
    D'Archivio, Angelo Antonio
    Incani, Angela
    Ruggieri, Fabrizio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 903 - 913
  • [30] The role of comprehensive two-dimensional gas chromatography in mineral oil determination
    Grégory Bauwens
    Aleksandra Gorska
    Giorgia Purcaro
    Analytical and Bioanalytical Chemistry, 2023, 415 : 5067 - 5082