Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers

被引:31
作者
Hillebrand, Arjan [1 ,2 ,3 ,4 ]
Holmes, Niall [5 ]
Sijsma, Ndedi [1 ,2 ]
O'Neill, George C. C. [6 ]
Tierney, Tim M. M. [6 ]
Liberton, Niels [7 ]
Stam, Anine H. H. [1 ,2 ]
van Klink, Nicole [8 ]
Stam, Cornelis J. J. [1 ,2 ,3 ,9 ]
Bowtell, Richard [5 ]
Brookes, Matthew J. J. [5 ]
Barnes, Gareth R. R. [6 ]
机构
[1] Amsterdam UMC Locat Vrije Univ Amsterdam, Dept Clin Neurophysiol, De Boelelaan 1117, NL-1081 Amsterdam, Netherlands
[2] Amsterdam UMC Locat Vrije Univ Amsterdam, Magnetoencephalog Ctr, De Boelelaan 1117, NL-1081HV Amsterdam, Netherlands
[3] Amsterdam Neurosci, Brain Imaging, Amsterdam, Netherlands
[4] Amsterdam Neurosci, Syst & Network Neurosci, Amsterdam, Netherlands
[5] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Phys & Astron, Univ Pk, Nottingham NG7 2RD, England
[6] UCL, UCL Queen Sq Inst Neurol, Wellcome Ctr Human Neuroimaging, Dept Imaging Neurosci, London WC1N, England
[7] Amsterdam UMC Locat Vrije Univ Amsterdam, Dept Med Technol, Innovat Lab 3D, Amsterdam, Netherlands
[8] Univ Med Ctr Utrecht, UMC Utrecht Brain Ctr, Dept Neurol & Neurosurg, Heidelberglaan 100, NL-3584 Utrecht, Netherlands
[9] Amsterdam Neurosci, Neurodegenerat, Amsterdam, Netherlands
基金
英国工程与自然科学研究理事会;
关键词
WHOLE-HEAD MEG; EPILEPTOGENIC ZONE; PRESURGICAL EVALUATION; ATOMIC MAGNETOMETER; MAGNETOENCEPHALOGRAPHY; EPILEPSY; EEG; INTERFERENCE; REGISTRATION; SENSITIVITY;
D O I
10.1038/s41598-023-31111-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance and/or logistical considerations. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and enabling recordings during seizures. We aimed to demonstrate the performance of OPMs in a clinical population. Seven patients with challenging cases of epilepsy underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system: three adults with known deep or weak (low SNR) sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures. The consistency of the recorded IEDs across the two systems was assessed. In one patient the OPMs detected IEDs that were not found with the SQUID-system, and in two patients no IEDs were found with either system. For the other patients the OPM data were remarkably consistent with the data from the cryogenic system, noting that these were recorded in different sessions, with comparable SNRs and IED-yields overall. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. The relatively affordable technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure.
引用
收藏
页数:15
相关论文
共 89 条
[1]   Noninvasive Detection of Hippocampal Epileptiform Activity on Scalp Electroencephalogram [J].
Abou Jaoude, Maurice ;
Jacobs, Claire S. ;
Sarkis, Rani A. ;
Jing, Jin ;
Pellerin, Kyle R. ;
Cole, Andrew J. ;
Cash, Sydney S. ;
Westover, M. Brandon ;
Lam, Alice D. .
JAMA NEUROLOGY, 2022, 79 (06) :614-622
[2]   Effective electromagnetic noise cancellation with beamformers and synthetic gradiometry in shielded and partly shielded environments [J].
Adjamian, P. ;
Worthen, S. F. ;
Hillebrand, A. ;
Furlong, P. L. ;
Chizh, B. A. ;
Hobson, A. R. ;
Aziz, Q. ;
Barnes, G. R. .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (01) :120-127
[3]   A qualitative awake EEG score for the diagnosis of continuous spike and waves during sleep (CSWS) syndrome in self-limited focal epilepsy (SFE): A case-control study [J].
Aeby, Alec ;
Santalucia, Roberto ;
Van Hecke, Audrey ;
Nebbioso, Andrea ;
Vermeiren, Justine ;
Deconinck, Nicolas ;
De Tiege, Xavier ;
Van Bogaert, Patrick .
SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2021, 84 :34-39
[4]   Magnetoencephalography of Epilepsy with a Microfabricated Atomic Magnetrode [J].
Alem, Orang ;
Benison, Alex M. ;
Barth, Daniel S. ;
Kitching, John ;
Knappe, Svenja .
JOURNAL OF NEUROSCIENCE, 2014, 34 (43) :14324-14327
[5]   Realistic spatial sampling for MEG beamformer images [J].
Barnes, GR ;
Hillebrand, A ;
Fawcett, IP ;
Singh, KD .
HUMAN BRAIN MAPPING, 2004, 23 (02) :120-127
[6]   Statistical flattening of MEG beamformer images [J].
Barnes, GR ;
Hillebrand, A .
HUMAN BRAIN MAPPING, 2003, 18 (01) :1-12
[7]   Occipitotemporal hippocampal depth electrodes in intracranial epilepsy monitoring: safety and utility [J].
Bekelis, Kimon ;
Desai, Atman ;
Kotlyar, Alex ;
Thadani, Vijay ;
Jobst, Barbara C. ;
Bujarski, Krzysztof ;
Darcey, Terrance M. ;
Roberts, David W. .
JOURNAL OF NEUROSURGERY, 2013, 118 (02) :345-352
[8]   Optimal design of on-scalp electromagnetic sensor arrays for brain source localisation [J].
Beltrachini, Leandro ;
von Ellenrieder, Nicolas ;
Eichardt, Roland ;
Haueisen, Jens .
HUMAN BRAIN MAPPING, 2021, 42 (15) :4869-4879
[9]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[10]   Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems [J].
Borna, Amir ;
Iivanainen, Joonas ;
Carter, Tony R. ;
McKay, Jim ;
Taulu, Samu ;
Stephen, Julia ;
Schwindt, Peter D. D. .
NEUROIMAGE, 2022, 247