A Low-Temperature Processed Organic Hole-Blocking Contact Layer for Amorphous Selenium X-Ray Photoconductor

被引:0
|
作者
Adnani, Sahar [1 ]
Pil-Ali, Abdollah
Karim, Karim S.
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Amorphous selenium (a-Se); X-ray detectors; hole-blocking layers; SU-8;
D O I
10.1109/LED.2023.3296332
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Amorphous selenium (a-Se) X-ray detectors have been used commercially for two decades in mammography because of their high spatial resolution. However, these devices face challenges in high spatial resolution tomography and angiography where lower radiation exposures and dynamic imaging are required. Higher voltages across the selenium layer can potentially improve sensitivity and temporal performance, but dark current is a concern. Although organic polyimide (PI) layers were previously demonstrated to have excellent hole-blocking properties that enabled high voltage mode operation with selenium devices, their higher baking and curing temperatures have restricted usage on the top surface of temperature-sensitive selenium as a hole-blocking layer. In this study, we explore low-temperature SU-8 as a hole-blocking layer for selenium. Our findings reveal that the devices with SU-8 as a hole-blocking layer in either top or bottom configurations maintained a dark current below 1 pA/mm(2) even at an increased electric field of 40 V/mu m. Devices with the SU-8 hole-blocking layer at the top surface exhibited a sensitivity loss of 18% after exposure to a cumulative 0.175 Gray (Gy) X-ray while maintaining lag or persistent photoconductivity below 1% at 20 V/mu m. As a comparison, devices fabricated in the same run that utilized the previously reported PI hole-blocking layer at the bottom surface resulted in a sensitivity drop of 24.1% and with lag of approximate to 3.1%. These results indicate that higher-performance selenium detectors are achievable with SU-8 blocking layers and can expedite the commercial development of low-lag, high-gain selenium X-ray detectors for dynamic medical imaging.
引用
收藏
页码:1528 / 1530
页数:3
相关论文
共 50 条
  • [31] TEMPERATURE-DEPENDENT X-RAY ABSORPTION STUDIES OF CRYSTALLINE AND AMORPHOUS SELENIUM
    SAYERS, DE
    LYTLE, FW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (03): : 345 - 345
  • [32] LOW-TEMPERATURE X-RAY TOPOGRAPHY - APPLICATION TO FERRIMAGNETIC GARNETS
    MATHIOT, A
    PETROFF, JF
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S149 - S149
  • [33] LOW-TEMPERATURE X-RAY STUDY OF UPD3
    SINGH, MA
    SMITH, SL
    NAGLER, SE
    BUYERS, WJL
    SOLID STATE COMMUNICATIONS, 1990, 74 (06) : 439 - 442
  • [34] X-RAY HEATING OF A LOW-TEMPERATURE REGION IN CHROMOSPHERIC FLARES
    SOMOV, BV
    SOLAR PHYSICS, 1975, 42 (01) : 235 - 246
  • [35] URNT-180 X-RAY LOW-TEMPERATURE DEVICE
    KOROLEVA, GM
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (02): : 270 - 270
  • [36] Low-Temperature Solution-Processed Hydrogen Molybdenum and Vanadium Bronzes for an Efficient Hole-Transport Layer in Organic Electronics
    Xie, Fengxian
    Choy, Wallace C. H.
    Wang, Chuandao
    Li, Xinchen
    Zhang, Shaoqing
    Hou, Jianhui
    ADVANCED MATERIALS, 2013, 25 (14) : 2051 - 2055
  • [37] LOW-TEMPERATURE X-RAY DIFFRACTION STUDIES ON VANADIUM SESQUIOXIDE
    WAREKOIS, EP
    JOURNAL OF APPLIED PHYSICS, 1960, 31 (05) : S346 - S347
  • [38] X-RAY STUDY OF LOW-TEMPERATURE PHASES OF ALKALI HYPEROXIDES
    ROSENFELD, M
    ZIEGLER, M
    KANZIG, W
    HELVETICA PHYSICA ACTA, 1978, 51 (02): : 298 - 320
  • [40] A low-temperature attachment for X-ray investigations in the magnetic field
    Zavarzina, O.L., 1995, Mezhdunarodnaya Kniga, Moscow, Russian Federation