A comprehensive numerical study based on topology optimization for cooling plates thermal design of battery packs

被引:25
作者
Zhong, Qixuan [1 ]
Chandra, Parthiv K. [1 ]
Li, Wei [2 ]
Gao, Liang [1 ]
Garg, Akhil [1 ]
Lv, Song [3 ]
Tai, K. [4 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan, Peoples R China
[2] Hefei Univ Technol, Sch Mech Engn, Hefei, Peoples R China
[3] Wuhan Univ Technol, Sch Marine & Power Engn, Wuhan, Peoples R China
[4] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore, Singapore
关键词
Battery cooling plates; Heat transfer; Topology optimization; Flow characteristics; Fluid volume; LI-ION BATTERY; MANAGEMENT-SYSTEM; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.121918
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article focuses on the problem of fluctuating cooling system flow caused by different working states such as acceleration and braking during the actual operation of electric vehicles, which prevents the system from effectively dissipating heat from the battery for a long time. In the past, liquid cooling heat dissipation schemes designed based on structural parameters often relied on the experience of CFD engineers. There is no in-depth study of the heat propagation characteristics. At present, research on the application of topology optimization method in cooling plate design mainly focuses on the relative positions of single inlet and outlet, objective functions, and constraint conditions. There are very few studies evaluating the adaptability of different cooling plate structures at different flow rates. In this perspective, this work proposes a two-dimensional topology optimization method for obtaining the cooling plates with different topological structures such as the series of cooling plate structures with dual entrances and exits. The method comprises of a comprehensive study on variations of the inlet flow rate under different average fluid volume fraction, outlet width, and temperature weight conditions. The results indicate that setting an excessive inlet flow rate can actually lead to an increase in the average temperature of the optimized cooling plate. Subsequently, the cooling plate structure obtained through topology optimization at inlet flow rates of 0.015 m/s, 0.02 m/s, and 0.025 m/s was selected, and a three-dimensional electrothermal fluid coupling model was established based on its two-dimensional channel structure. Its cooling performance, flow characteristics, and heat transfer characteristics were analyzed, and compared with two straight channel reference models. The results indicate that the optimized cooling plate structure under low flow conditions has better heat dissipation performance. At a flow rate of 0.56 x At 10-6m3/ s, compared to traditional cooling plates(CASE D, CASE E), the highest temperature of the battery using topology optimized cooling plates (CASE A) decreased by 3.5 K and 1.79 K, respectively, and the standard deviation of temperature decreased by 48% and 14%, respectively. Under the same inlet flow velocity, the area of the fluid region increases with the increase of the mean fluid volume fraction, and the width of the flow channel increases gradually and the branches increase significantly, from the concentrated solid region to the dispersed isolated region. At a low flow rate, the normalized temperature of the cooling plate increases with the increase of the flow rate of the coolant inlet, and when the flow rate reaches a certain value, in order to reduce the power loss of the cooling plate, the flow path is gradually concentrated on both sides of the cooling plate. This leads to the decline of the normalized temperature of the cooling plate.
引用
收藏
页数:18
相关论文
共 38 条
[1]   A comparative study between air cooling and liquid cooling thermal management systems for a high-energy lithium-ion battery module [J].
Akbarzadeh, Mohsen ;
Kalogiannis, Theodoros ;
Jaguemont, Joris ;
Jin, Lu ;
Behi, Hamidreza ;
Karimi, Danial ;
Beheshti, Hamidreza ;
Van Mierlo, Joeri ;
Berecibar, Maitane .
APPLIED THERMAL ENGINEERING, 2021, 198
[2]   Topology optimization design and numerical analysis on cold plates for lithium-ion battery thermal management [J].
Chen, Fan ;
Wang, Jiao ;
Yang, Xinglin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
[3]   Thermal analysis of lithium-ion batteries [J].
Chen, SC ;
Wan, CC ;
Wang, YY .
JOURNAL OF POWER SOURCES, 2005, 140 (01) :111-124
[4]   A comprehensive analysis and optimization process for an integrated liquid cooling plate for a prismatic lithium-ion battery module [J].
Chen, Siqi ;
Peng, Xiongbin ;
Bao, Nengsheng ;
Garg, Akhil .
APPLIED THERMAL ENGINEERING, 2019, 156 :324-339
[5]   Study on thermal management of rectangular Li-ion battery with serpentine-channel cold plate [J].
Deng, Tao ;
Zhang, Guodong ;
Ran, Yan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 :143-152
[6]   Effects of different coolants and cooling strategies on the cooling performance of the power lithium ion battery system: A review [J].
Deng, Yuanwang ;
Feng, Changling ;
E, Jiaqiang ;
Zhu, Hao ;
Chen, Jingwei ;
Wen, Ming ;
Yin, Huichun .
APPLIED THERMAL ENGINEERING, 2018, 142 :10-29
[7]   Comparison of modeling predictions with experimental data from plastic lithium ion cells [J].
Doyle, M ;
Newman, J ;
Gozdz, AS ;
Schmutz, CN ;
Tarascon, JM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (06) :1890-1903
[8]   Experimental investigation on mini-channel cooling-based thermal management for Li-ion battery module under different cooling schemes [J].
Du, Xueping ;
Qian, Zhen ;
Chen, Zhilin ;
Rao, Zhonghao .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (08) :2781-2788
[9]   Numerical investigation on lithium-ion battery thermal management utilizing a novel tree-like channel liquid cooling plate exchanger [J].
Fan, Yiwei ;
Wang, Zhaohui ;
Fu, Ting ;
Wu, Huawei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
[10]   Body-fitted topology optimization of 2D and 3D fluid-to-fluid heat exchangers [J].
Feppon, F. ;
Allaire, G. ;
Dapogny, C. ;
Jolivet, P. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2021, 376